Three portable tonometers, the TGDc-01, the ICARE and the Tonopen XL, compared with each other and with Goldmann applanation tonometry

被引:82
|
作者
van der Jagt, LH [1 ]
Jansonius, NM [1 ]
机构
[1] Univ Groningen, Med Ctr, Dept Ophthalmol, NL-9700 RB Groningen, Netherlands
关键词
corneal thickness; glaucoma; impact tonometer; intraocular pressure; rebound tonometer;
D O I
10.1111/j.1475-1313.2005.00318.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Three portable tonometers, the TGDc-01, the ICARE and the Tonopen XL, were compared with each other and to Goldmann applanation tonometry in a large group of healthy subjects and patients with ocular hypertension or glaucoma (n = 103). Measurements performed with the ICARE and the Tonopen XL were in good agreement with that of the Goldmann tonometer. Intraocular pressure (IOP) values measured with the TGDc-01 were significantly lower and showed more variability. The 95% limits of agreement (portable tonometer - Goldmann) were -17 to +10 mmHg for the TGDc-01, -6 to +7 mmHg for the ICARE and -6 to +8 mmHg for the Tonopen. Corneal thickness could not explain the differences between an IOP measured with the portable tonometers and an IOP measured with the Goldmann tonometer. Patient comfort was slightly higher for ICARE when compared with the Tonopen.
引用
收藏
页码:429 / 435
页数:7
相关论文
共 12 条
  • [1] Evaluation of TGDc-01 compared with Goldmann applanation tonometry
    Rombold, F
    Thiel, MJ
    Neubauer, AS
    Hirneiss, C
    Kampik, A
    OPHTHALMOLOGE, 2005, 102 (02): : 158 - 162
  • [2] Comparison of the transpalpebral tonometer TGDc-01 with Goldmann applanation tonometry
    Waisbourd, Michael
    Shemesh, Gabi
    Top, Lea Baras
    Lazar, Moshe
    Loewenstein, Anat
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2010, 20 (05) : 902 - 906
  • [3] Evaluation des mobilen TGDc-01-Tonometers und Vergleich mit dem Applanationstonometer nach GoldmannEvaluation of TGDc-01 compared with Goldmann applanation tonometry
    F. Rombold
    M. J. Thiel
    A. S. Neubauer
    C. Hirneiß
    A. Kampik
    Der Ophthalmologe, 2005, 102 (2): : 158 - 162
  • [4] Deviations between transpalpebral tonometry using TGDc-01 and Goldmann applanation tonometry depending on the IOP level
    Troost, A
    Specht, K
    Krummenauer, F
    Yun, SH
    Schwenn, O
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2005, 243 (09) : 853 - 858
  • [5] Deviations between transpalpebral tonometry using TGDc-01 and Goldmann applanation tonometry depending on the IOP level
    Annette Troost
    Kathrin Specht
    Frank Krummenauer
    Sung Hyun Yun
    Oliver Schwenn
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2005, 243 : 853 - 858
  • [6] Transpalpebral measurement of intraocular pressure using the TGDc-01 tonometer versus standard Goldmann applanation tonometry
    Lösch, A
    Scheuerle, A
    Rupp, V
    Auffarth, G
    Becker, M
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2005, 243 (04) : 313 - 316
  • [7] Transpalpebral measurement of intraocular pressure using the TGDc-01 tonometer versus standard Goldmann applanation tonometry
    Annette Lösch
    Alexander Scheuerle
    Volker Rupp
    Gerd Auffarth
    Matthias Becker
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2005, 243 : 313 - 316
  • [8] The validity of a digital eyelid tonometer (TGDc-01) and its comparison with Goldmann applanation tonometry - a pilot study
    Lam, AKC
    Lam, CH
    Chan, R
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2005, 25 (03) : 205 - 210
  • [9] Intraocular pressure difference in goldmann applanation tonometry versus a transpalpebral tonometer TGDc-01 "PRA" in glaucoma patients
    Schlote, T
    Landenberger, H
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2005, 222 (02) : 123 - 131
  • [10] Agreement among Goldmann applanation tonometer, iCare, and Icare PRO rebound tonometers; non-contact tonometer; and Tonopen XL in healthy elderly subjects
    Kato, Yoshitake
    Nakakura, Shunsuke
    Matsuo, Naoko
    Yoshitomi, Kayo
    Handa, Marina
    Tabuchi, Hitoshi
    Kiuchi, Yoshiaki
    INTERNATIONAL OPHTHALMOLOGY, 2018, 38 (02) : 687 - 696