LC/MS with a particle beam interface in forensic toxicology

被引:0
|
作者
Spratt, E [1 ]
Vallaro, GM [1 ]
机构
[1] Westchester Cty Dept Labs & Res, Valhalla, NY USA
关键词
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Many instruments are used in forensic toxicology to screen biologic samples for drugs and other compounds. Many of these screening instruments (and others) are used to confirm positive screening tests. The focus of this article is the use of a high pressure liquid chromatograph/mass spectrometer (HPLC/MS) for screening forensic postmortem and human performance DWI cases. This screening procedure involves an HPLC with a particle beam interfaced to a mass spectrometer detector and a photodiode array detector. Drugs such as the antidepressants, drugs of abuse, over-the-counter cold and pain preparations, anticonvulsants, benzodiazepines, and some medications that are not available in the United States are selected at therapeutic and subtherapeutic levels. Limits of detection and extraction efficiencies are presented for many compounds. Several cases are discussed showing different drug combinations.
引用
收藏
页码:651 / +
页数:14
相关论文
共 50 条
  • [1] The application of LC-MS in forensic toxicology
    Dussy, FE
    Stäubli, CH
    Briellmann, TA
    [J]. CHIMIA, 2002, 56 (03) : 53 - 58
  • [2] Development of a system suitability test for forensic toxicology applications of LC/MS/MS
    Sasaki, Tania A.
    Sellers, Kristi
    Schreiber, Andre
    Hcrwehe, Kenneth
    [J]. THERAPEUTIC DRUG MONITORING, 2007, 29 (04) : 493 - 493
  • [3] INTRODUCTION TO PARTICLE BEAM LC/MS
    APFFEL, JA
    NORDMAN, RG
    [J]. HEWLETT-PACKARD JOURNAL, 1990, 41 (03): : 69 - 76
  • [4] DETERMINATION OF AFLATOXINS IN PEANUT MEAL BY LC/MS WITH A PARTICLE-BEAM INTERFACE
    CAPPIELLO, A
    FAMIGLINI, G
    TIRILLINI, B
    [J]. CHROMATOGRAPHIA, 1995, 40 (7-8) : 411 - 416
  • [5] EVALUATION OR THE PERFORMANCE OF A MICROFLOW RATE LC/MS PARTICLE-BEAM INTERFACE
    CAPPIELLO, A
    FAMIGLINI, G
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (22) : 3970 - 3976
  • [6] An LC/particle beam/MS experiment for undergraduates
    Sproch, N
    Begin, KJ
    Morris, RJ
    [J]. JOURNAL OF CHEMICAL EDUCATION, 1996, 73 (02) : A33 - A39
  • [7] QUANTITATIVE PERFORMANCE OF PARTICLE BEAM LC/MS
    APFFEL, A
    FRAZIER, LC
    BROWN, M
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1989, 197 : 49 - AGRO
  • [8] LC-MS-MS vs ELISA: Validation of a Comprehensive Urine Toxicology Screen by LC-MS-MS and a Comparison of 100 Forensic Specimens
    Kahl, Kristin W.
    Seither, Joshua Z.
    Reidy, Lisa J.
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 2019, 43 (09) : 734 - 745
  • [9] Comparison of the performances of a particle beam LC-MS interface obtained by standard and modified skimmers
    Magi, E
    Di Carro, M
    [J]. ANNALI DI CHIMICA, 2003, 93 (03) : 241 - 248
  • [10] NEW APPROACH FOR THE ANALYSIS OF ACIDIC PESTICIDES IN WATER BY LC/MS WITH A PARTICLE-BEAM INTERFACE
    CAPPIELLO, A
    FAMIGLINI, G
    PALMA, P
    BERLONI, A
    BRUNER, F