The stability and reproducibility of Tris buffers in synthetic seawater

被引:54
|
作者
Nemzer, BV [1 ]
Dickson, AG [1 ]
机构
[1] Univ Calif San Diego, Marine Phys Lab, Scripps Inst Oceanog, La Jolla, CA 92093 USA
基金
美国国家科学基金会;
关键词
artificial seawater; pH; buffers; accuracy; stability;
D O I
10.1016/j.marchem.2005.01.004
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The equimolal Tris buffer (0.04 mol/kg-H2O Tris+0.04 mol/kg-H2O Tris-HCl) prepared in synthetic seawater of salinity 35 has been shown to be stable when sealed in a borosilicate glass bottle with a greased ground-glass stopper (drift rate <= 0.0005 in pH per year). The error in pH of such buffers resulting from uncertainties in the preparation of such buffers is typically less than 0.002 in pH (relative to the results of DelValls and Dickson, 1998 [DelValls, T.A., Dickson, A.G., 1998. The pH of buffers based on 2-amino-2-hydroxymethyl-1,3-propanediol ('tris') in synthetic sea water. Deep-Sea Research 1, 45, 1541-1554]). (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:237 / 242
页数:6
相关论文
共 50 条
  • [1] Preparation of 2-amino-2-hydroxymethyl-1,3-propanediol (TRIS) pHT buffers in synthetic seawater
    Paulsen, May-Linn
    Dickson, Andrew G.
    LIMNOLOGY AND OCEANOGRAPHY-METHODS, 2020, 18 (09): : 504 - 515
  • [2] Measurement of pHT values of Tris buffers in artificial seawater at varying mole ratios of Tris:Tris•HCl
    Pratt, Kenneth W.
    MARINE CHEMISTRY, 2014, 162 : 89 - 95
  • [3] STABILITY OF AST AND ALT ASSAYS IN TRIS BUFFERS
    PRASAD, R
    FIRKINS, K
    FIORELLO, J
    CLINICAL CHEMISTRY, 1990, 36 (02) : 407 - 408
  • [4] STABILITY AND REPRODUCIBILITY OF BUFFERS EMPLOYED IN BLOOD PH DETERMINATION
    FRIEDMAN, I
    STOKLOSA, JC
    ANESTHESIA AND ANALGESIA CURRENT RESEARCHES, 1965, 44 (05): : 540 - &
  • [5] The effects of pressure on pH of Tris buffer in synthetic seawater
    Takeshita, Yuichiro
    Martz, Todd R.
    Coletti, Luke J.
    Dickson, Andrew G.
    Jannasch, Hans W.
    Johnson, Kenneth S.
    MARINE CHEMISTRY, 2017, 188 : 1 - 5
  • [6] ACID-BASE PROPERTIES OF TRIS(HYDROXYMETHYL)AMINOMETHANE (TRIS) BUFFERS IN SEAWATER FROM 5 TO 40 DEGREESC
    RAMETTE, RW
    CULBERSON, CH
    BATES, RG
    ANALYTICAL CHEMISTRY, 1977, 49 (06) : 867 - 870
  • [7] The effects of biological buffers TRIS, TAPS, TES on the stability of lysozyme
    Pannuru, Pavani
    Rani, Anjeeta
    Venkatesu, Pannuru
    Lee, Ming-Jer
    INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2018, 112 : 720 - 727
  • [8] Seawater pH measurements with a combination glass electrode and high ionic strength TRIS-TRIS HCl reference buffers - An uncertainty evaluation approach
    Anes, Barbara
    Bettencourt da Silva, Ricardo J. N.
    Oliveira, Cristina
    Filomena Camoes, M.
    TALANTA, 2019, 193 : 118 - 122
  • [9] MOVING BOUNDARY ELECTROPHORESIS IN TRIS BUFFERS
    COBB, BF
    KOENIG, VL
    INTERNATIONAL JOURNAL OF PROTEIN RESEARCH, 1971, 3 (06): : 301 - &
  • [10] Technical note: Stability of tris pH buffer in artificial seawater stored in bags
    Wolfe, Wiley H.
    Shipley, Kenisha M.
    Bresnahan, Philip J.
    Takeshita, Yuichiro
    Wirth, Taylor
    Martz, Todd R.
    OCEAN SCIENCE, 2021, 17 (03) : 819 - 831