A treadmill ergometer for three-dimensional ground reaction forces measurement during walking

被引:112
|
作者
Belli, A [1 ]
Bui, P
Berger, A
Geyssant, A
Lacour, JR
机构
[1] Univ St Etienne, Lab Physiol GIP Exercice, St Etienne, France
[2] Univ Lyon 1, Lab Physiol GIP Exercice, F-69365 Lyon, France
关键词
D O I
10.1016/S0021-9290(00)00125-1
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This report describes new treadmill ergometer designed to measure the vertical and horizontal ground reaction forces produced by the left and right legs during walking. It was validated by static and dynamic tests. Non linearity was from 0.2% (left vertical force) to 1.4% (right antero-posterior force). The resonance frequency was from 219 (right vertical direction) to 58 Hz (left medio-lateral direction). A calibration "leg", an air jack in series with a strain gauge, was developed and used to produce force signals comparable to those obtained during human locomotion. The mean differences between the force measured by the calibration leg and treadmill ergometer at 5 km h(-1) were 3.7 N (0.7%) for the left side and 6.5 N (1.2%) for the right. Measurements obtained during human walking showed that the treadmill ergometer has considerable potential for analysing human gait. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:105 / 112
页数:8
相关论文
共 50 条
  • [1] Variability of ground reaction forces during treadmill walking
    Masani, K
    Kouzaki, M
    Fukunaga, T
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2002, 92 (05) : 1885 - 1890
  • [2] Comparison of vertical ground reaction forces during overground and treadmill walking
    White, SC
    Yack, HJ
    Tucker, CA
    Lin, HY
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1998, 30 (10): : 1537 - 1542
  • [3] Three-dimensional hindfoot kinematics during treadmill walking and running
    Milner, CE
    Soames, RW
    [J]. JOURNAL OF SPORTS SCIENCES, 2002, 20 (01) : 13 - 14
  • [4] A Three-Dimensional Mass-Spring Walking Model Could Describe the Ground Reaction Forces
    Liang, Huiqi
    Xie, Wenbo
    Zhang, Zhiqiang
    Wei, Peizi
    Cui, Changhui
    [J]. MATHEMATICAL PROBLEMS IN ENGINEERING, 2021, 2021
  • [5] A cycle ergometer mounted on a standard force platform for three-dimensional pedal forces measurement during cycling
    Mornieux, Guillaume
    Zameziati, Karim
    Mutter, Elodie
    Bonnefoy, Regis
    Belli, Alain
    [J]. JOURNAL OF BIOMECHANICS, 2006, 39 (07) : 1296 - 1303
  • [6] Three-Dimensional Kinematic Coupling of the Healthy Knee During Treadmill Walking
    Koo, Young-Jun
    Koo, Seungbum
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2019, 141 (08):
  • [7] The effect of severe obesity on three-dimensional ground reaction force signals during walking
    Patoz, Aurelien
    Menendez, Aitor Fernandez
    Malatesta, Davide
    [J]. CLINICAL BIOMECHANICS, 2023, 107
  • [8] Functional analysis of the gibbon foot during terrestrial bipedal walking:: Plantar pressure distributions and three-dimensional ground reaction forces
    Vereecke, E
    D'Août, K
    Van Elsacker, L
    De Clercq, D
    Aerts, P
    [J]. AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 2005, 128 (03) : 659 - 669
  • [9] Three-dimensional kinematics of the lumbar spine during treadmill walking at different speeds
    V. Feipel
    T. De Mesmaeker
    P. Klein
    M. Rooze
    [J]. European Spine Journal, 2001, 10 : 16 - 22
  • [10] Estimation of Three-Dimensional Ground Reaction Forces During Walking and Turning Using Insole Pressure Sensors Based on Gait Pattern Recognition
    Eguchi, Ryo
    Takahashi, Masaki
    [J]. IEEE SENSORS JOURNAL, 2023, 23 (24) : 31278 - 31286