Comparative study for the production of monoclonal antibodies in single-use vs stainless steel bioreactors based on product quality and stress factor

被引:1
|
作者
Beck, Christian [1 ]
Werz, Silke [1 ]
Herrmann, Alexander [1 ]
Meiringer, Christoph T. A. [1 ]
机构
[1] Roche Diagnost GmbH, Pharma Biotech Penzberg, D-82377 Penzberg, Germany
关键词
bioreactor; comparison; fermentation; monoclonal antibody; single-use; stainless steel;
D O I
10.1002/eng2.12197
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Single-use bioreactors (SUB) and stainless steel bioreactors (SSB) differ in their physical properties. This can have an effect on the performed processes. To be able to guarantee flexible planning in a facility, any kind of processes in SUB and SSB must be sufficiently similar. To date, assessments of SUB and SSB have been exclusively specific for one single product. This study shows a general nonproduct-specific comparison of the production of different types of monoclonal antibodies in different scales of SUBs and SSBs. The study is set up with 72 clinical manufacturing fermentation runs in total by comparing the cell culture performance and quality attributes of these two bioreactor systems. The outcome is that SUBs and SSBs can produce monoclonal antibodies with comparable cell culture performance and product quality. This general comparability paves the way for SUBs to produce new and existing products for (clinical) manufacturing.
引用
收藏
页数:11
相关论文
共 15 条
  • [1] Single use bioreactors for the clinical production of monoclonal antibodies – a study to analyze the performance of a CHO cell line and the quality of the produced monoclonal antibody
    Sonja Diekmann
    Constanze Dürr
    Alexander Herrmann
    Ingo Lindner
    Daniela Jozic
    BMC Proceedings, 5 (Suppl 8)
  • [2] Defining the implementation of single-use technology: a comparative evaluation of a single-use bioreactor with a stainless-steel bioreactor
    Blanc, Geoffrey
    Leroy, Severine
    Leroy, Celine
    Gueraische, Nicolas
    Borgne, Cedric
    Brown, Stephen
    PHARMACEUTICAL BIOPROCESSING, 2013, 1 (04) : 341 - 349
  • [3] Comparison of hydrodynamics in standard stainless steel and single-use bioreactors by means of an Euler-Lagrange approach
    Delafosse, Angelique
    Calvo, Sebastien
    Collignon, Marie-Laure
    Toye, Dominique
    CHEMICAL ENGINEERING SCIENCE, 2018, 188 : 52 - 64
  • [4] Characterization Data for the Establishment of Scale-Up and Process Transfer Strategies between Stainless Steel and Single-Use Bioreactors
    Bernemann, Vincent
    Fitschen, Juergen
    Leupold, Marco
    Scheibenbogen, Karl-Heinz
    Maly, Marc
    Hoffmann, Marko
    Wucherpfennig, Thomas
    Schlueter, Michael
    FLUIDS, 2024, 9 (05)
  • [5] An environmental life cycle assessment comparison of single-use and conventional process technology for the production of monoclonal antibodies
    Pietrzykowski, Matthew
    Flanagan, William
    Pizzi, Vincent
    Brown, Andrew
    Sinclair, Andrew
    Monge, Miriam
    JOURNAL OF CLEANER PRODUCTION, 2013, 41 : 150 - 162
  • [6] Comparative study of bluetongue virus serotype 8 production on BHK-21 cells in a 50L Biostat® STR single-use bioreactors vs roller bottles
    Lídia Garcia
    Mercedes Mouriño
    Alicia Urniza
    BMC Proceedings, 7 (Suppl 6)
  • [7] Transient Transfection-Based Lentivirus (LV) Production Process Scaled to 25 L in Single-Use Bioreactors
    Sheikholeslami, Zahra
    Ramanuj, Rajan
    Beaudette, Philip
    Razvi, Azher
    MOLECULAR THERAPY, 2021, 29 (04) : 388 - 389
  • [8] Comparative medico-economic study of reusable vs. single-use flexible ureteroscopes
    Khalid Al-Balushi
    Nathalie Martin
    Hélène Loubon
    Michael Baboudjian
    Floriane Michel
    Pierre-Clément Sichez
    Thomas Martin
    Eugénie Di-Crocco
    Sarah Gaillet
    Veronique Delaporte
    Akram Akiki
    Alice Faure
    Gilles Karsenty
    Eric Lechevallier
    Romain Boissier
    International Urology and Nephrology, 2019, 51 : 1735 - 1741
  • [9] Comparative medico-economic study of reusable vs. single-use flexible ureteroscopes
    Al-Balushi, Khalid
    Martin, Nathalie
    Loubon, Helene
    Baboudjian, Michael
    Michel, Floriane
    Sichez, Pierre-Clement
    Martin, Thomas
    Di-Crocco, Eugenie
    Gaillet, Sarah
    Delaporte, Veronique
    Akiki, Akram
    Faure, Alice
    Karsenty, Gilles
    Lechevallier, Eric
    Boissier, Romain
    INTERNATIONAL UROLOGY AND NEPHROLOGY, 2019, 51 (10) : 1735 - 1741
  • [10] Characterization of the Metabolic Response of Streptomyces clavuligerus to Shear Stress in Stirred Tanks and Single-Use 2D Rocking Motion Bioreactors for Clavulanic Acid Production
    Gomez-Rios, David
    Junne, Stefan
    Neubauer, Peter
    Ochoa, Silvia
    Rios-Estepa, Rigoberto
    Ramirez-Malule, Howard
    ANTIBIOTICS-BASEL, 2019, 8 (04):