Coumarins as new matrices for matrix-assisted laser-desorption/ionization Fourier transform ion cyclotron resonance mass spectrometric analysis of hydrophobic compounds

被引:10
|
作者
Wang, Hang [1 ]
Dai, Bona [1 ]
Liu, Bin [2 ]
Lu, Han [3 ]
机构
[1] Shanghai Jiao Tong Univ, Instrumental Anal Ctr, Shanghai 200240, Peoples R China
[2] Hubei Polytech Univ, Coll Med, Key Lab Kidney Dis Pathogenesis & Intervent Hubei, Huangshi 435003, Hubei, Peoples R China
[3] Shanghai Jiao Tong Univ, Ruijin Hosp, Sch Med, Dept Anesthesiol, Shanghai 200025, Peoples R China
基金
中国国家自然科学基金;
关键词
Coumarins; Hydrophobic compounds; Matrix-assisted laser desorption/ionization; Mass spectrometry; Yeast sterols; ELECTROSPRAY-IONIZATION; GAS-CHROMATOGRAPHY; DRUG-RESISTANCE; MALDI MATRIX; TIME; DERIVATIZATION; OLIGOSACCHARIDES; CHOLESTEROL; QUANTIFICATION; MECHANISMS;
D O I
10.1016/j.aca.2015.04.050
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Hydrophobic compounds with hydroxyl, aldehyde or ketone groups are generally difficult to detect using matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS), because these compounds have low proton affinity and are poorly ionized by MALDI. Herein, coumarins have been used as new matrices for MALDI-MS analysis of a variety of hydrophobic compounds with low ionization efficiency, including steroids, coenzyme Q10, a cyclic lipopeptide and cholesterol oleate. Five coumarins, including coumarin, umbelliferone, esculetin, 7-hydroxycoumarin-3-carboxylic acid (HCA) and 6,7-dihydroxycoumarin-3-carboxylic acid (DCA), were compared with the conventional matrices of 2,5-dihydroxybenzoic acid (DHB) and alpha-cyano-4-hydroxycinnamic acid (CHCA). Coumarins with hydroxyl or carboxylic acid groups enabled detection. Taking DCA as an example, this matrix proved to be superior to DHB or CHCA in detection sensitivity, stability, spot-to-spot and sample-to-sample reproducibility, and accuracy. DCA increased the stability of the target compounds and decreased the loss of water. The [M + Na](+) peaks were observed for all target compounds by adding NaCl as an additive, and the [M - H2O + H](+) and [M + H](+) peaks decreased. DCA was selected for the identification of sterols in yeast cells, and thirteen sterols were detected by Fourier transform ion cyclotron resonance (FT ICR) mass spectrometry. This work demonstrates the potential of DCA as a new matrix for detection of hydrophobic molecules by MALDI-MS and provides an alternative tool for screening sterols in antifungal research. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:49 / 57
页数:9
相关论文
共 50 条
  • [1] ATTOMOLE BIOMOLECULE MASS ANALYSIS BY MATRIX-ASSISTED LASER-DESORPTION IONIZATION FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE
    SOLOUKI, T
    MARTO, JA
    WHITE, FM
    GUAN, SH
    MARSHALL, AG
    ANALYTICAL CHEMISTRY, 1995, 67 (22) : 4139 - 4144
  • [2] Matrix-assisted laser desorption ionization and electrospray ionization combined with Fourier transform ion cyclotron resonance mass spectrometry
    Staneke, PO
    Nibbering, NMM
    SPECTROSCOPY-AN INTERNATIONAL JOURNAL, 1997, 13 (02): : 145 - 150
  • [3] Matrix-assisted laser desorption/ionization and Fourier transform ion cyclotron resonance mass spectrometry of metalloporphyrazines and metallophthalocyanines
    Morkved, E
    Kjosen, H
    Vedde, J
    Uggerud, E
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2002, 8 (01) : 35 - 39
  • [4] Development of cryostage for matrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry
    Naito, Y
    Miyabayashi, K
    Tsujimoto, K
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 221 (02) : 83 - 92
  • [5] STRUCTURAL CHARACTERIZATION OF PHOSPHOLIPIDS BY MATRIX-ASSISTED LASER-DESORPTION IONIZATION FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY
    MARTO, JA
    WHITE, FM
    SELDOMRIDGE, S
    MARSHALL, AG
    ANALYTICAL CHEMISTRY, 1995, 67 (21) : 3979 - 3984
  • [6] Analysis and quantitation of fructooligosaccharides using matrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry
    Seipert, Richard R.
    Barboza, Mariana
    Ninonuevo, Milady R.
    LoCascio, Riccardo G.
    Mills, David A.
    Freeman, Samara L.
    German, J. Bruce
    Lebrilla, Carlito B.
    ANALYTICAL CHEMISTRY, 2008, 80 (01) : 159 - 165
  • [7] Electrospray ionization and matrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry of permethylated oligosaccharides
    Solouki, T
    Reinhold, BB
    Costello, CE
    O'Malley, M
    Guan, SH
    Marshall, AG
    ANALYTICAL CHEMISTRY, 1998, 70 (05) : 857 - 864
  • [8] In-cell matrix-assisted laser desorption-ionization Fourier transform ion cyclotron resonance mass spectrometry
    Knobeler, M
    Wanczek, KP
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1996, 7 (10) : 1026 - 1033
  • [9] Two-Dimensional Fourier Transform Ion Cyclotron Resonance Mass Spectrometry by Matrix-Assisted Laser Desorption Ionization
    Bell, Richard J.
    Hage, David S.
    Dodds, Eric D.
    ANALYTICAL CHEMISTRY, 2024, 96 (17) : 6584 - 6587
  • [10] MATRIX-ASSISTED LASER-DESORPTION IONIZATION FOURIER-TRANSFORM MASS-SPECTROMETRY
    SHENG, LS
    COVEY, JE
    SHEW, SL
    WINGER, BE
    CAMPANA, JE
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (06) : 498 - 500