Head helmet versus face mask for non-invasive continuous positive airway pressure: a physiological study

被引:105
|
作者
Patroniti, N [1 ]
Foti, G [1 ]
Manfio, A [1 ]
Coppo, A [1 ]
Bellani, G [1 ]
Pesenti, A [1 ]
机构
[1] Univ Milano Bicocca, Osped San Gerardo Nuovo Tintori, Dept Anesthesia & Intens Care, I-20052 Milan, Italy
关键词
continuous positive airway pressure; head helmet; face mask; hypoxemic respiratory failure; healthy volunteers;
D O I
10.1007/s00134-003-1931-8
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective. To assess selected physiological effects of non-invasive continuous positive airway pressure delivered by head helmet (CPAP(H)), a special interface device designed to completely contain the head of the patient, compared to face mask (CPAP(M)). Design. Randomized physiological study. Setting. University research laboratory. Patients. Eight healthy volunteers. Intervention. Continuous positive airway pressure delivered by face mask and CPAP(H) in random order. Three gas flow rates (20-30-40 l/min and 30-45-60 l/min, respectively, for CPAP(M) and CPAP(H)) and four CPAP levels (0-5-10-15 cmH(2)O) were employed in a randomized sequence. Measurements and results. In each patient we monitored airway pressure, esophageal pressure, expiratory flow, and inspiratory and expiratory CO2 concentration. End-expiratory lung volume changes from CPAP 0 were measured by inductance plethysmography. The application of increased levels of CPAP resulted in a significant increase in end-expiratory lung volume, similar for CPAP(H) and CPAP(M). Inspiratory changes of airway pressure were comparable for the two CPAP modes. Inspiratory CO2 concentration was higher during CPAP(H) (significantly decreased at increased gas flow rates), compared to CPAP(M). Conclusions. Continuous positive airway pressure delivered by head helmet is as effective as CPAP(M) in increasing end-expiratory lung volume and in compensating for airway pressure changes without the need of a reservoir bag. Higher gas flow rates are necessary to maintain a relatively low inspiratory CO2 concentration.
引用
收藏
页码:1680 / 1687
页数:8
相关论文
共 50 条
  • [1] Head helmet versus face mask for non-invasive continuous positive airway pressure: a physiological study
    Nicolò Patroniti
    Giuseppe Foti
    Annamaria Manfio
    Anna Coppo
    Giacomo Bellani
    Antonio Pesenti
    Intensive Care Medicine, 2003, 29 : 1680 - 1687
  • [2] Non-invasive continuous positive airway pressure using a new helmet interface
    L'Her, E
    Tonnelier, J
    Prat, G
    Goetghebeur, D
    Renault, A
    Boles, J
    INTENSIVE CARE MEDICINE, 2002, 28 : S23 - S23
  • [3] Continuous positive airway pressure by mask or helmet: An "in vitro" study
    Pelosi, P
    Aspesi, M
    Chiaranda, M
    Colombo, G
    Conti, G
    Gamberoni, C
    Noudem, Y
    Pennisi, M
    Severgnini, P
    INTENSIVE CARE MEDICINE, 2001, 27 : S198 - S198
  • [4] Continuous Positive Airway Pressure With Helmet Versus Mask in Infants With Bronchiolitis: An RCT
    Chidini, Giovanna
    Piastra, Marco
    Marchesi, Tiziana
    De Luca, Daniele
    Napolitano, Luisa
    Salvo, Ida
    Wolfler, Andrea
    Pelosi, Paolo
    Damasco, Mirco
    Conti, Giorgio
    Calderini, Edoardo
    PEDIATRICS, 2015, 135 (04) : E868 - E875
  • [5] Noninvasive Continuous Positive Airway Pressure in Acute Respiratory Failure: Helmet Versus Facial Mask
    Chidini, Giovanna
    Calderini, Edoardo
    Cesana, Bruno Mario
    Gandini, Cristiano
    Prandi, Edi
    Pelosi, Paolo
    PEDIATRICS, 2010, 126 (02) : E330 - E336
  • [6] CONTINUOUS POSITIVE AIRWAY PRESSURE IN ADULTS BY FACE MASK
    GREENBAUM, DM
    MILLEN, JE
    EROSS, B
    SYNDER, JV
    GRENVIK, A
    SAFAR, P
    CRITICAL CARE MEDICINE, 1976, 4 (02) : 114 - 115
  • [7] CONTINUOUS POSITIVE AIRWAY PRESSURE (CPAP) BY FACE MASK
    SMITH, RA
    KIRBY, RR
    GOODING, JM
    CIVETTA, JM
    CRITICAL CARE MEDICINE, 1980, 8 (09) : 483 - 485
  • [8] CONTINUOUS POSITIVE AIRWAY PRESSURE APPLIED BY FACE MASK
    HARRIS, TR
    PEDIATRIC RESEARCH, 1972, 6 (04) : 410 - &
  • [9] NONINVASIVE CONTINUOUS POSITIVE AIRWAY PRESSURE (NCPAP) BY HELMET VERSUS FACIAL MASK: A MULTICENTER RCT
    Chidini, G.
    Piastra, M.
    Wolfler, A.
    Marchesi, T.
    Calderini, E.
    Conti, G.
    Pelosi, P.
    INTENSIVE CARE MEDICINE, 2011, 37 : S331 - S332
  • [10] Performance of a new "helmet" versus a standard face mask during non-invasive mechanical ventilation
    Chiumello, D
    Carlesso, E
    Cadisco, A
    Paganini, S
    Libassi, G
    Storelli, E
    Rocchi, G
    INTENSIVE CARE MEDICINE, 2002, 28 : S49 - S49