Synthetic Mesh Augmentation of Acute and Subacute Quadriceps Tendon Repair

被引:18
|
作者
Morrey, Matthew C. [1 ]
Barlow, Jonathan D. [2 ]
Abdel, Matthew P. [3 ]
Hanssen, Arlen D. [3 ]
机构
[1] Univ Texas Hlth Sci Ctr San Antonio, San Antonio, TX 78229 USA
[2] Ohio State Univ, Hand & Upper Extrem Ctr, Columbus, OH 43210 USA
[3] Mayo Clin, Dept Orthoped Surg, 200 First St SW, Rochester, MN 55905 USA
关键词
SUTURE ANCHORS; DELAYED REPAIR; RUPTURES; RECONSTRUCTION;
D O I
10.3928/01477447-20151218-02
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Quadriceps tendon rupture is an uncommon injury. To date, surgical results have been less than favorable. A novel repair technique that uses Marlex mesh (C R Bard, Murray Hill, New Jersey) has been developed. Use of this repair may allow earlier range of motion and functional restoration of extension. The authors sought to evaluate the technical feasibility, durability, and postoperative function of this repair. This study retrospectively analyzed 8 knees (7 patients) operated on with this technique from 1990 to 2011. Mean follow-up was 9 years. Average age at the time of injury was 69 years. Mean operative time was 130 minutes. No perioperative complications occurred, no patients had clinical evidence of failure, and no patients required subsequent reoperation. Mean flexion at final follow-up was 100 degrees. Of the 8 knees, 7 knees had no extensor lag at final follow-up. Marlex mesh augmentation for quadriceps tendon ruptures has promising clinical results, despite significant comorbidities. The results showed that the technique was feasible, with low cost and reasonable operative time. The clinical results were durable, with no intraoperative complications, no re-ruptures, rare extension lag, and good range of motion. Therefore, synthetic mesh augmentation is a feasible option in acute quadriceps tendon ruptures.
引用
收藏
页码:E9 / E13
页数:5
相关论文
共 50 条
  • [1] Quadriceps tendon repair using hamstring, prolene mesh and autologous conditioned plasma augmentation. A novel technique for repair of chronic quadriceps tendon rupture
    Rehman, Haroon
    Kovacs, Peter
    KNEE, 2015, 22 (06): : 664 - 668
  • [2] The Outcome of Acute Quadriceps Tendon Rupture Managed with Primary Repair and Mersilene Tape Augmentation
    Akgun, Rahmi Can
    Tandogan, N. Reha
    Sahin, Orcun
    TURKIYE KLINIKLERI TIP BILIMLERI DERGISI, 2009, 29 (02): : 438 - 444
  • [3] Synthetic Mesh Reconstruction of Chronic, Native Quadriceps Tendon Disruptions following Failed Primary Repair
    Hartline, Braden E.
    Wilson, Jacob M.
    Schwartz, Andrew M.
    Roberson, James R.
    Guild, George N., III
    CASE REPORTS IN ORTHOPEDICS, 2021, 2021
  • [4] Acellular dermal graft augmentation in quadriceps tendon rupture repair
    Wilkins, Ross M.
    CURRENT ORTHOPAEDIC PRACTICE, 2010, 21 (03): : 315 - 319
  • [5] Arthroscopic suture repair of acute quadriceps tendon ruptures
    Severyns, M.
    Renard, G.
    Guillou, R.
    Odri, G. A.
    Labrada-Blanco, O.
    Rouvillain, J. L.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (03) : 377 - 380
  • [6] Delayed repair of a quadriceps tendon
    Katzman, BM
    Silberberg, S
    Caligiuri, DA
    Klein, DM
    DiPaolo, P
    ORTHOPEDICS, 1997, 20 (06) : 553 - 554
  • [7] Patellar Bone-Tendon-Bone Autografts versus Quadriceps Tendon Allograft with Synthetic Augmentation in a Canine Model
    Smith, Patrick A.
    Stannard, James P.
    Bozynski, Chantelle C.
    Kuroki, Keiichi
    Cook, Cristi R.
    Cook, James L.
    JOURNAL OF KNEE SURGERY, 2020, 33 (12) : 1256 - 1266
  • [8] Chronic Quadriceps Tendon Rupture After Total Knee Arthroplasty Augmented With Synthetic Mesh
    Ormaza, Amaia
    Moreta, Jesus
    Mosquera, Javier
    Saez de Ugarte, Oskar
    Luis Martinez-de los Mozos, Jose
    ORTHOPEDICS, 2017, 40 (01) : 38 - 42
  • [9] Traumatic Patellar Tendon Rupture Repair Using Synthetic Ligament Augmentation
    Core, Maxime
    Anract, Philippe
    Raffin, Juliette
    Biau, David Jean
    JOURNAL OF KNEE SURGERY, 2020, 33 (08) : 804 - 809
  • [10] Repair of Quadriceps and Patellar Tendon Tears
    Danaher, Michael
    Faucett, Scott C.
    Endres, Nathan K.
    Geeslin, Andrew G.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2023, 39 (02): : 142 - 144