摘要
Research published on the axial compressive behavior of fibre-reinforced polymer (FRP)-confined concrete columns has been generally based on small-sized specimens. There have been limited studies published on large-sized columns and there have also been limited studies on the validity of upscaling results obtained from small-sized specimens. On account of such knowledge gap, this paper presents the test results of 23 carbon FRP-confined square concrete columns of varying sizes subjected to monotonic axial compression. The specimens were sorted into 10 groups based on (i) specimen size, (ii) theoretical lateral FRP confining pressure, (iii) number of layers of FRP wrap, and (iv) inclusion and exclusion of internal steel reinforcement. In each group, the specimens consisted of different cross-sectional sizes but the same theoretical lateral confining pressure. The experimental results showed that specimen size had no significant effect on the axial stress-strain behavior of FRP-confined medium- and small-sized columns (i.e. sections defined herein equal to and less than 300 mm in width). The axial stress-strain responses exhibited differences as the specimen size increased. This was especially the case for FRP-confined large-sized columns (i.e. sections defined herein equal to and larger than 350 mm in width). The rupture strain of the FRP wrap at the corner regions is proposed to be defined as the effective lateral rupture strain of FRP, and this strain was shown to decrease with an increase of specimen size. Based on the test results, a modified FRP effective strain factor model considering the influence of size effect is proposed. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:116 / 126
页数:11
相关论文
共 50 条
  • [1] CFRP-Confined Square RC Columns. II: Cyclic Axial Compression Stress-Strain Model
    Wang, Zhenyu
    Wang, Daiyu
    Smith, Scott T.
    Lu, Dagang
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2012, 16 (02) : 161 - 170
  • [2] Axial stress-strain behavior of pre-stressed CFRP confined concrete columns
    Wang, Qiang
    Liu, Xin
    Liu, Yuhao
    Liang, Xuhua
    Lu, Chunling
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 446
  • [3] Axial Compressive Behavior of CFRP-Confined Expansive Concrete Columns
    Cao, Qi
    Tao, Jinju
    Ma, Zhongguo John
    Wu, Zhimin
    ACI STRUCTURAL JOURNAL, 2017, 114 (02) : 475 - 485
  • [4] Stress-strain model and design guidelines for CFRP-confined circular reinforced concrete columns
    Al-Rousan, Rajai Z.
    Issa, Mohsen A.
    POLYMER COMPOSITES, 2018, 39 (08) : 2722 - 2733
  • [5] Axial Stress-Strain Model of CFRP-Confined Concrete under Monotonic and Cyclic Loading
    Hany, Najwa F.
    Hantouche, Elie G.
    Harajli, Mohamed H.
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2015, 19 (06)
  • [6] STRENGTH MODEL FOR CFRP-CONFINED CONCRETE IN SQUARE COLUMNS
    Benzaid, Riad
    Mesbah, Habib-Abdelhak
    Amel, Bouhabila
    IRF2016: 5TH INTERNATIONAL CONFERENCE INTEGRITY-RELIABILITY-FAILURE, 2016, : 1385 - 1398
  • [7] Modeling the axial compressive stress-strain behavior of CFRP-confined rectangular RC columns under monotonic and cyclic loading
    Isleem, Haytham F.
    Wang, Daiyu
    Wang, Zhenyu
    COMPOSITE STRUCTURES, 2018, 185 : 229 - 240
  • [8] A design-oriented stress-strain model for CFRP-confined fully replaced coal gangue aggregate concrete square columns
    Xiang, Zehui
    Dai, Yiling
    Yin, Lingfeng
    STRUCTURES, 2024, 69
  • [9] Stress-strain model for CFRP moderately-confined reinforced concrete square columns
    Wang, Zhenyu
    Wang, Daiyu
    Lü, Dagang
    Guo, Ruifeng
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2011, 32 (04): : 101 - 109
  • [10] Effect of low strain rate on the axial behavior of concrete in CFRP-confined circular cylinders
    Cao, Yugui
    Liu, Muyu
    Wu, Yu-Fei
    CONSTRUCTION AND BUILDING MATERIALS, 2020, 255