The interference of electronic implants in low frequency electromagnetic fields

被引:0
|
作者
Silny, J [1 ]
机构
[1] Univ Aachen Hosp, Res Ctr Bioelectromagnet Interact Femu, D-52074 Aachen, Germany
关键词
electromagnetic interference; electronic implant; health;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Electronic implants such as cardiac pacemakers or nerve stimulators can be impaired in different ways by amplitude-modulated and even continuous electric or magnetic fields of strong field intensities. For the implant bearer, possible consequences of a temporary electromagnetic interference may range from a harmless impairment of his well-being to a perilous predicament. Electromagnetic interferences in all types of implants cannot be covered here due to their various locations in the body and their different sensing systems. Therefore, this presentation focuses exemplarily on the most frequently used implant, the cardiac pacemaker. In case of an electromagnetic interference the cardiac pacemaker reacts by switching to inhibition mode or to fast asynchronous pacing. At a higher disturbance voltage on the input of the pacemaker, a regular asynchronous pacing is likely to arise. In particular, the first-named interference could be highly dangerous for the pacemaker patient. The interference threshold of cardiac pacemakers depends in a complex way on a number of different factors such as: electromagnetic immunity and adjustment of the pacemaker, the composition of the applied low-frequency fields (only electric or magnetic fields or combinations of both), their frequencies and modulations, the type of pacemaker system (bipolar, unipolar) and its location in the body, as well as the body size and orientation in the field, and last but not least, certain physiological conditions of the patient (e.g. inhalation, exhalation). In extensive laboratory studies we have investigated the interference mechanisms in more than 100 cardiac pacemakers (older types as well as current models) and the resulting worst-case conditions for pacemaker patients in low-frequency electric and magnetic fields. The verification of these results in different practical everyday-life situations, e.g. in the fields of high-voltage overhead lines or those of electronic article surveillance systems is currently in progress. In case of the vertically-oriented electric 50 Hz fields preliminary results show that per 1 kV/m unimpaired electrical field strength (rms) an interference voltage of about 400 muVpp as worst-case could occur at the input of a unipolar ventricularly controlled, left-pectorally implanted cardiac pacemaker. Thus, already a field strength above ca. 5 kV/m could cause an interference with an implanted pacemaker. The magnetic fields induces an electric disturbance voltage at the input of the pacemaker. The body and the pacemaker system compose several induction loops, whose induced voltages rates add or subtract. The effective area of one representing inductive loop ranges from 100 to 221 cm(2). For the unfavourable left-pectorally implantated and atrially-controlled pacemaker with a low interference threshold, the interference threshold ranges between 552 and 16 muT (rms) for magnetic fields at frequencies between 10 and 250 Hz. On this basis the occurrence of interferences with implanted pacemakers is possible in everyday-life situations. But experiments demonstrate a low probability of interference of cardiac pacemakers in practical situations. This apparent contradiction can be explained by a very small band of inhibition in most pacemakers and, in comparison with the worst-case, deviating conditions.
引用
收藏
页码:30 / 34
页数:5
相关论文
共 50 条
  • [1] Electromagnetic interference in cardiac electronic implants caused by novel electrical appliances emitting electromagnetic fields in the intermediate frequency range: a systematic review
    Driessen, Sarah
    Napp, Andreas
    Schmiedchen, Kristina
    Kraus, Thomas
    Stunder, Dominik
    [J]. EUROPACE, 2019, 21 (02): : 219 - 229
  • [2] Influence of Electromagnetic Fields by Electronic Implants in Medicine
    Psenakova, Z.
    Hudecova, J.
    [J]. ELEKTRONIKA IR ELEKTROTECHNIKA, 2009, (07) : 37 - 40
  • [3] Interference voltage measurement and analysis of cardiac implants exposed to electric fields at extremely low frequency
    Zhou, Mengxi
    Kourtiche, Djilali
    Claudel, Julien
    Deschamps, Francois
    Magne, Isabelle
    Roth, Patrice
    Schmitt, Pierre
    Nadi, Mustapha
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2024, 10 (04):
  • [4] Aspects of electromagnetic interference in low frequencies ranges Electromagnetic interference in the 50 Hz frequency
    Otahal, Jiri
    Hruska, Frantisek
    [J]. 2014 15TH INTERNATIONAL CARPATHIAN CONTROL CONFERENCE (ICCC), 2014, : 413 - 417
  • [5] Electromagnetic interference with cardiac pacemakers and implantable cardioverter-defibrillators from low-frequency electromagnetic fields in vivo
    Tiikkaja, Maria
    Aro, Aapo L.
    Alanko, Tommi
    Lindholm, Harri
    Sistonen, Heli
    Hartikainen, Juha E. K.
    Toivonen, Lauri
    Juutilainen, Jukka
    Hietanen, Maila
    [J]. EUROPACE, 2013, 15 (03): : 388 - 394
  • [6] Angular momentum of low frequency electromagnetic fields
    Weber, H.
    [J]. OPTIK, 2013, 124 (20): : 4313 - 4314
  • [7] Ultra and extremely low frequency electromagnetic fields
    Surkov, Vadim
    Hayakawa, Masashi
    [J]. Ultra and Extremely Low Frequency Electromagnetic Fields, 2014, : 1 - 486
  • [8] Computation of low-frequency electromagnetic fields
    VanRienen, U
    Clemens, M
    Weiland, T
    [J]. ZEITSCHRIFT FUR ANGEWANDTE MATHEMATIK UND MECHANIK, 1996, 76 : 567 - 568
  • [9] MOLECULAR WEIGHT OF WATER AND LOW FREQUENCY ELECTROMAGNETIC FIELDS
    BORDI, S
    VANNEL, F
    [J]. GEOFISICA E METEOROLOGIA, 1965, 14 (5-6): : 129 - &
  • [10] Effects of extremely low frequency electromagnetic fields on turkeys
    Laszlo, Anna M.
    Ladanyi, Marta
    Boda, Krisztina
    Csicsman, Jozsef
    Bari, Ferenc
    Serester, Andrea
    Molnar, Zsolt
    Sepp, Krisztian
    Galfi, Marta
    Radacs, Marianna
    [J]. POULTRY SCIENCE, 2018, 97 (02) : 634 - 642