Diagnostic accuracy of TB-LAMP for pulmonary tuberculosis: a systematic review and meta-analysis

被引:42
|
作者
Shete, Priya B. [1 ,2 ,3 ]
Farr, Katherine [1 ,2 ,3 ]
Strnad, Luke [4 ]
Gray, Christen M. [5 ]
Cattamanchi, Adithya [1 ,2 ,3 ]
机构
[1] Univ Calif San Francisco, Div Pulm & Crit Care Med, 1001 Potrero Ave,5K1, San Francisco, CA 94110 USA
[2] Zuckerberg San Francisco Gen Hosp, 1001 Potrero Ave,5K1, San Francisco, CA 94110 USA
[3] Univ Calif San Francisco, Curry Int TB Ctr, San Francisco, CA 94143 USA
[4] Oregon Hlth & Sci Univ, Div Infect Dis, 3188 SW Sam Jackson Pk Rd,Mail Code L457, Portland, OR 97239 USA
[5] London Sch Hyg & Trop Med, Fac Epidemiol & Populat Hlth, Room G30,Keppel St, London WC1E 7HT, England
关键词
Tuberculosis; Diagnostic testing; Molecular assay; Point of care; MEDIATED ISOTHERMAL AMPLIFICATION; MYCOBACTERIUM-TUBERCULOSIS;
D O I
10.1186/s12879-019-3881-y
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
BackgroundThe need for a rapid, molecular test to diagnose tuberculosis (TB) has prompted exploration of TB-LAMP (Eiken; Tokyo, Japan) for use in resource-limited settings. We conducted a systematic review to assess the accuracy of TB-LAMP as a diagnostic test for pulmonary TB.MethodsWe analyzed individual-level data for eligible patients from all studies of TB-LAMP conducted between Jan 2012 and October 2015 to compare the diagnostic accuracy of TB-LAMP with that of smear microscopy and Xpert MTB/RIF (R) using 3 reference standards of varying stringency. Pooled sensitivity and specificity and pooled differences in sensitivity and specificity were estimated using random effects meta-analysis. Study quality was evaluated using QUADAS-2.ResultsFour thousand seven hundred sixty individuals across 13 studies met eligibility criteria. Methodological quality was judged to be low for all studies. TB-LAMP had higher sensitivity than sputum smear microscopy (pooled sensitivity difference+132, 95% CI 45-219%) and similar sensitivity to Xpert MTB/RIF (pooled sensitivity difference-25, 95% CI -80 to +29) using the most stringent reference standard available. Specificity of TB-LAMP was similar to that of sputum smear microscopy (pooled specificity difference-18, 95% CI -38 to +02) and Xpert MTB/RIF (pooled specificity difference 05, 95% CI -09 to +18).ConclusionsFrom the perspective of diagnostic accuracy, TB-LAMP may be considered as an alternative test for sputum smear microscopy. Additional factors such as cost, feasibility, and acceptability in settings that continue to rely on sputum smear microscopy should be considered when deciding to adopt this technology. Xpert MTB/RIF should continue to be preferred in settings where resource and infrastructure requirements are adequate and where HIV co-infection or drug-resistance is of concern.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Diagnostic accuracy of TB-LAMP for pulmonary tuberculosis: a systematic review and meta-analysis
    Priya B. Shete
    Katherine Farr
    Luke Strnad
    Christen M. Gray
    Adithya Cattamanchi
    BMC Infectious Diseases, 19
  • [2] Diagnostic Yield of Oral Swab Testing by TB-LAMP for Diagnosis of Pulmonary Tuberculosis
    Song, Yanhua
    Ma, Yifeng
    Liu, Rongmei
    Shang, Yuanyuan
    Ma, Liping
    Huo, Fengmin
    Li, Yunxu
    Shu, Wei
    Wang, Yufeng
    Gao, Mengqiu
    Pang, Yu
    INFECTION AND DRUG RESISTANCE, 2021, 14 : 89 - 95
  • [3] Diagnostic accuracy of oral swab for detection of pulmonary tuberculosis: a systematic review and meta-analysis
    Zhang, Fuzhen
    Wang, Yilin
    Zhang, Xuxia
    Liu, Kewei
    Shang, Yuanyuan
    Wang, Wei
    Liu, Yuanyuan
    Li, Liang
    Pang, Yu
    FRONTIERS IN MEDICINE, 2024, 10
  • [4] Diagnostic Accuracy of Loop-Mediated Isothermal Amplification (TB-LAMP) for Tuberculosis in Children
    Promsena, Pathariya
    Jantarabenjakul, Watsamon
    Suntarattiwong, Piyarat
    Sudjaritruk, Tavitiya
    Anugulruengkitt, Suvaporn
    Rotcheewaphan, Suwatchareeporn
    Petsong, Suthidee
    Sawangsinth, Panadda
    Sophonphan, Jiratchaya
    Tawan, Monta
    Moonwong, Juthamanee
    Puthanakit, Thanyawee
    JOURNAL OF THE PEDIATRIC INFECTIOUS DISEASES SOCIETY, 2022, 11 (01) : 9 - 15
  • [5] Diagnostic accuracy of TB-LAMP assay in patients with pulmonary tuberculosis-a case-control study in northern India
    Yadav, R.
    Daroch, P.
    Gupta, P.
    Agarwal, P.
    Aggarwal, A. N.
    Sethi, S.
    PULMONOLOGY, 2022, 28 (06): : 449 - 453
  • [6] Diagnostic accuracy of echocardiography for pulmonary hypertension: a systematic review and meta-analysis
    Janda, Surinder
    Shahidi, Neal
    Gin, Kenneth
    Swiston, John
    HEART, 2011, 97 (08) : 612 - 622
  • [7] Diagnostic accuracy of nanopore sequencing for the rapid diagnosis of pulmonary tuberculosis: A protocol for a systematic review and meta-analysis
    Yu, Guocan
    Xu, Xudong
    Shen, Yanqin
    Fang, Bifei
    PLOS ONE, 2024, 19 (06):
  • [8] Diagnostic Accuracy of the Artificial Intelligence Methods in Medical Imaging for Pulmonary Tuberculosis: A Systematic Review and Meta-Analysis
    Zhan, Yuejuan
    Wang, Yuqi
    Zhang, Wendi
    Ying, Binwu
    Wang, Chengdi
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (01)
  • [9] Diagnostic accuracy of metagenomic next-generation sequencing in pulmonary tuberculosis: a systematic review and meta-analysis
    Yajie You
    Ying meng Ni
    Guochao Shi
    Systematic Reviews, 13 (1)
  • [10] A systematic review and meta-analysis of diagnostic test accuracy of chest ultrasound in diagnosing pediatric pulmonary tuberculosis
    Muljadi, Rusli
    Koesbandono
    Octavius, Gilbert S.
    PEDIATRIC PULMONOLOGY, 2024, 59 (10) : 2381 - 2391