Objective measurement of intraocular forward light scatter using Hartmann-Shack spot patterns from clinical aberrometers -: Model-eye and human-eye study

被引:11
|
作者
Cervino, Alejandro [1 ]
Bansal, Dheeraj [2 ]
Hosking, Sarah L. [3 ,4 ,5 ]
Montes-Mico, Robert
机构
[1] Univ Valencia, Dept Opt, Optometry Res Grp, E-46100 Valencia, Spain
[2] Optopol Technol SA, Zawiercie, Poland
[3] City Univ London, Dept Optometry & Vis Sci, London EC1V 0HB, England
[4] Aston Univ, Sch Life & Hlth Sci, Birmingham B4 7ET, W Midlands, England
[5] Univ Melbourne, Dept Ophthalmol, Melbourne, Vic, Australia
来源
JOURNAL OF CATARACT AND REFRACTIVE SURGERY | 2008年 / 34卷 / 07期
关键词
D O I
10.1016/j.jcrs.2008.03.027
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To apply software-based image-analysis tools to objectively determine intraocular scatter determined from clinically derived Hartmann-Shack patterns. SETTING: Aston Academy of Life Sciences, Aston University, Birmingham, United Kingdom, and Department of Optics, University of Valencia, Valencia, Spain. METHODS: Purpose-designed image-analysis software was used to quantify scatter from centroid patterns obtained using a clinical Hartmann-Shack analyzer (WASCA, Zeiss/Meditec). Three scatter values, as the maximum standard deviation within a lenslet for all lenslets in the pattern, were obtained in 6 model eyes and 10 human eyes. In the model-eye sample, patterns were obtained in 4 sessions: 2 without realigning between measurements, 1 with realignment, and 1 with an angular shift of 6 degrees from the instrument axis. Three measurements were made in the human eyes with the C-Quant straylight meter (Oculus) to obtain psychometric and objective measures of retinal straylight. Analysis of variance, intraclass correlation coefficients, coefficient of repeatability (CoR), and correlations were used to determine intrasession and intersession repeatability and the relationship between measures. RESULTS: No significant differences were found between the sessions in the model eye (P = .234). The mean CoR was less than 10% in all model- and human-eye sessions. After incomplete patterns were removed, good correlation was achieved between psychometric and objective scatter measurements despite the small sample size (n = 6; r = -0.831; P = .040). CONCLUSIONS: The methodology was repeatable in model and human eyes, strong against realignment and misalignment, and sensitive. Clinical application would benefit from effective use of the sensor's dynamic range.
引用
收藏
页码:1089 / 1095
页数:7
相关论文
共 5 条
  • [1] Objective measurement of wave aberrations of the human eye with the use of a Hartmann-Shack wave-front sensor
    Liang, Junzhong
    Grimm, Bernhard
    Goelz, Stefan
    Bille, Josef F.
    Journal of the Optical Society of America A: Optics and Image Science, and Vision, 1994, 11 (07): : 1949 - 1957
  • [2] OBJECTIVE MEASUREMENT OF WAVE ABERRATIONS OF THE HUMAN EYE WITH THE USE OF A HARTMANN-SHACK WAVE-FRONT SENSOR
    LIANG, JZ
    GRIMM, B
    GOELZ, S
    BILLE, JF
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1994, 11 (07): : 1949 - 1957
  • [3] Comparison of forward light scatter estimations using Shack-Hartmann spot patterns and a straylight meter
    Lopez, Pablo Benito
    Radhakrishnan, Hema
    Nourrit, Vincent
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (02): : 320 - 326
  • [4] Evaluation of paraxial forward scattering from intraocular lens with increased surface light scattering using goniophotometry and Hartmann-Shack wavefront aberrometry
    Keiichiro Minami
    Yoko Maruyama
    Toshifumi Mihashi
    Kazunori Miyata
    Tetsuro Oshika
    Japanese Journal of Ophthalmology, 2017, 61 : 189 - 194
  • [5] Evaluation of paraxial forward scattering from intraocular lens with increased surface light scattering using goniophotometry and Hartmann-Shack wavefront aberrometry
    Minami, Keiichiro
    Maruyama, Yoko
    Mihashi, Toshifumi
    Miyata, Kazunori
    Oshika, Tetsuro
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2017, 61 (02) : 189 - 194