Validity and reliability of GPS and LPS for measuring distances covered and sprint mechanical properties in team sports

被引:157
|
作者
Hoppe, Matthias W. [1 ]
Baumgart, Christian [1 ]
Polglaze, Ted [2 ]
Freiwald, Juergen [1 ]
机构
[1] Univ Wuppertal, Dept Movement & Training Sci, Wuppertal, Germany
[2] Univ Western Australia, Exercise & Sport Sci, Sch Human Sci, Perth, WA, Australia
来源
PLOS ONE | 2018年 / 13卷 / 02期
关键词
LOCAL POSITION MEASUREMENT; 10; HZ; MOVEMENT PATTERNS; SOCCER MATCH; ACCURACY; PERFORMANCE; VELOCITY; DEVICES; SYSTEM; ACCELERATION;
D O I
10.1371/journal.pone.0192708
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study aimed to investigate the validity and reliability of global (GPS) and local (LPS) positioning systems for measuring distances covered and sprint mechanical properties in team sports. Here, we evaluated two recently released 18 Hz GPS and 20 Hz LPS technologies together with one established 10 Hz GPS technology. Six male athletes (age: 27 +/- 2 years; VO(2)max: 48.8 +/- 4.7 ml/min/kg) performed outdoors on 10 trials of a team sport-specific circuit that was equipped with double-light timing gates. The circuit included various walking, jogging, and sprinting sections that were performed either in straight-lines or with changes of direction. During the circuit, athletes wore two devices of each positioning system. From the reported and filtered velocity data, the distances covered and sprint mechanical properties (i.e., the theoretical maximal horizontal velocity, force, and power output) were computed. The sprint mechanical properties were modeled via an inverse dynamic approach applied to the center of mass. The validity was determined by comparing the measured and criterion data via the typical error of estimate (TEE), whereas the reliability was examined by comparing the two devices of each technology (i.e., the between-device reliability) via the coefficient of variation (CV). Outliers due to measurement errors were statistically identified and excluded from validity and reliability analyses. The 18 Hz GPS showed better validity and reliability for determining the distances covered (TEE: 1.6-8.0%; CV: 1.1-5.1%) and sprint mechanical properties (TEE: 4.5-14.3%; CV: 3.1-7.5%) than the 10 Hz GPS (TEE: 3.0-12.9%; CV: 2.5-13.0% and TEE: 4.1-23.1%; CV: 3.3-20.0%). However, the 20 Hz LPS demonstrated superior validity and reliability overall (TEE: 1.0-6.0%; CV: 0.7-5.0% and TEE: 2.1-9.2%; CV: 1.6-7.3%). For the 10 Hz GPS, 18 Hz GPS, and 20 Hz LPS, the relative loss of data sets due to measurement errors was 10.0%, 20.0%, and 15.8%, respectively. This study shows that 18 Hz GPS has enhanced validity and reliability for determining movement patterns in team sports compared to 10 Hz GPS, whereas 20 Hz LPS had superior validity and reliability overall. However, compared to 10 Hz GPS, 18 Hz GPS and 20 Hz LPS technologies had more outliers due to measurement errors, which limits their practical applications at this time.
引用
收藏
页数:21
相关论文
共 47 条
  • [1] Validity and reliability of Polar M400 GPS watches for measuring distances covered by team sports players
    Makar, Piotr
    Kawczynski, Adam
    Silva, Rui Miguel
    Yildiz, Mehmet
    Silva, Ana Filipa
    Akyildiz, Zeki
    HELIYON, 2023, 9 (10)
  • [2] Validity and reliability of GPS devices for measuring movement demands of team sports
    Coutts, Aaron J.
    Duffield, Rob
    JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2010, 13 (01) : 133 - 135
  • [3] Validity and reliability of GPS for measuring distance travelled in field-based team sports
    Gray, Adrian J.
    Jenkins, David
    Andrews, Mark H.
    Taaffe, Dennis R.
    Glover, Megan L.
    JOURNAL OF SPORTS SCIENCES, 2010, 28 (12) : 1319 - 1325
  • [4] Concurrent Validity of GPS for Deriving Mechanical Properties of Sprint Acceleration
    Nagahara, Ryu
    Botter, Alberto
    Rejc, Enrico
    Koido, Masaaki
    Shimizu, Takeshi
    Samozino, Pierre
    Morin, Jean-Benoit
    INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2017, 12 (01) : 129 - 132
  • [5] Validity and reliability of Polar Team Pro GPS units for assessing maximum sprint speed in soccer players
    Sagiroglu, Isa
    Akyildiz, Zeki
    Yildiz, Mehmet
    Clemente, Filipe Manuel
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART P-JOURNAL OF SPORTS ENGINEERING AND TECHNOLOGY, 2023, 237 (04) : 309 - 316
  • [6] RELIABILITY AND FACTORIAL VALIDITY OF FLEXIBILITY TESTS FOR TEAM SPORTS
    Sporis, Goran
    Vucetic, Vlatko
    Jovanovic, Mario
    Jukic, Igor
    Omrcen, Darija
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2011, 25 (04) : 1168 - 1176
  • [7] The Validity and Reliability of Wearable Microtechnology for Intermittent Team Sports: A Systematic Review
    Crang, Zachary L.
    Duthie, Grant
    Cole, Michael H.
    Weakley, Jonathon
    Hewitt, Adam
    Johnston, Rich D.
    SPORTS MEDICINE, 2021, 51 (03) : 549 - 565
  • [8] The Performance Enhancement Attitude Scale in Team Sports; Validity and Reliability Study
    Uysal, Yucel
    Toros, Turhan
    Cetin, Mehmet Cagri
    Ozyol, Funda Coskun
    Serin, Emre
    Guzel, Sinan
    Ozturk, Rabia Yildiz
    PROGRESS IN NUTRITION, 2022, 24
  • [9] Assessing the Reliability and Validity of Agility Testing in Team Sports: A Systematic Review
    Morral-Yepes, Monica
    Moras, Gerard
    Bishop, Chris
    Gonzalo-Skok, Oliver
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2022, 36 (07) : 2035 - 2049
  • [10] The Validity and Reliability of Wearable Microtechnology for Intermittent Team Sports: A Systematic Review
    Zachary L. Crang
    Grant Duthie
    Michael H. Cole
    Jonathon Weakley
    Adam Hewitt
    Rich D. Johnston
    Sports Medicine, 2021, 51 : 549 - 565