Hierarchical frequency control strategy of doubly-fed induction diesel generator under emergency condition

被引:0
|
作者
Liu, Zhichao [1 ]
Li, Junlin [2 ]
Mao, Chengxiong [1 ]
Wang, Dan [1 ]
Guan, Zhitao [1 ]
Xie, Cong [1 ]
Li, Jingqi [1 ]
Qi, Yuanzhuo [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Elect & Elect Engn, Wuhan 430074, Peoples R China
[2] Guangzhou Power Grid Co Ltd, Guangzhou Power Supply Bur, Guangzhou 510699, Peoples R China
关键词
Natural disaster; Variable speed doubly-fed induction diesel generator; Hierarchical frequency control; Virtual inertia control;
D O I
10.1016/j.egyr.2022.02.257
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Natural disasters lead to the uncertain topological structure of the urban distribution network. It is difficult for the communication system to recover quickly, which brings great difficulties to restoring the power supply. Therefore, the deployment of an emergency power supply is one of the critical measures to ensure the stable operation of isolated network systems and reduce power loss. Compared with the traditional synchronous diesel generator (SDG) as an emergency power supply, a doubly-fed induction diesel generator (DFIDG) has the advantages of flexible and controllable, rapid response and high operation efficiency. This paper presents a layered frequency control strategy for a doubly-fed induction diesel generator in an emergency scenario. Firstly, the models of doubly-fed induction diesel generator and its control system, prime mover and its speed regulation system are established. Secondly, the hierarchical frequency control strategy is proposed, including primary integrated frequency control (including droop control and virtual inertia control) and secondary frequency regulation control based on translation method. The virtual inertia control can make the doubly-fed machine quickly release the rotor kinetic energy when the frequency changes rapidly, so as to improve the frequency supportability. According to the overall shortage of the system and the maximum output power of the doubly-fed induction diesel generator, the strategy calculates the secondary frequency regulation power adjustment as the DFIDG power setting value, and then can realize automatic secondary frequency regulation without a communication system. Finally, simulation results verify the effectiveness of the proposed strategy. (c) 2022 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). Peer-review under responsibility of the scientific committee of the 2021 The 2nd International Conference on Power Engineering, ICPE, 2021.
引用
收藏
页码:657 / 667
页数:11
相关论文
共 50 条
  • [1] Hierarchical frequency control strategy of doubly-fed induction diesel generator under emergency condition
    Liu, Zhichao
    Li, Junlin
    Mao, Chengxiong
    Wang, Dan
    Guan, Zhitao
    Xie, Cong
    Li, Jingqi
    Qi, Yuanzhuo
    Energy Reports, 2022, 8 : 657 - 667
  • [2] Composite frequency control strategy of doubly-fed induction generator wind turbines
    Zhu, X.-R., 1600, Power System Protection and Control Press (40):
  • [3] Doubly-Fed Induction Generator Control Under Voltage Sags
    Lima, K.
    Luna, A.
    Rodriguez, P.
    Watanabe, E.
    Teodorescu, R.
    Blaabjerg, F.
    2008 IEEE ENERGY 2030 CONFERENCE, 2008, : 511 - +
  • [4] VSCF doubly-fed induction generator control strategy and simulation research
    Wang, Rongxi
    Lin, Fei
    Hao, Ruixiang
    You, Xiaojie
    Zheng, Trillion Q.
    ICIEA 2008: 3RD IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, PROCEEDINGS, VOLS 1-3, 2008, : 2045 - 2050
  • [5] Control Strategy of Doubly-Fed Induction Generator under Zero Voltage Fault of Power Grid
    Ye, Yi
    Yang, Zelin
    Hu, Jiawei
    Yi, Haopeng
    Zhang, Lu
    SUSTAINABILITY, 2022, 14 (23)
  • [6] Virtual Synchronous Control Strategy for Doubly-Fed Induction Generator under Asymmetrical Grid Faults
    Cheng, Xuekun
    Sun, Xudong
    Chai, Jianyun
    Zhao, Yangyang
    2017 20TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2017,
  • [7] Frequency control strategy of doubly-fed induction generators considering frequency deviation
    Xu Y.
    Yang D.
    Zheng T.
    Zhang X.
    Hua L.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2022, 43 (10): : 229 - 235
  • [8] Coordinated control strategy for doubly-fed induction generator with DC connection topology
    Nian, Heng
    Yi, Xilu
    IET RENEWABLE POWER GENERATION, 2015, 9 (07) : 747 - 756
  • [9] A new control strategy for doubly-fed induction generator for wind power generation
    Nho, Eui-Cheol
    Su, Chia-Wei
    Liao, Chih-Sheng
    Li, Lihua
    Davis-Marsh, Marc E.
    Smedley, Keyue Ma
    APEC 2007: TWENTY-SECOND ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1 AND 2, 2007, : 514 - +
  • [10] Direct Stator Current Phase Control strategy of Doubly-fed Induction Generator
    Zhe, Li
    Ge, Li
    Zheng, Gao
    ICEMS 2008: PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1- 8, 2008, : 2408 - 2411