Energy-efficient air conditioning system using a three-fluid heat exchanger for simultaneous and control

被引:18
|
作者
Liang, Chenjiyu [1 ]
Wang, Yuan [1 ]
Li, Xianting [1 ]
机构
[1] Tsinghua Univ, Sch Architecture, Dept Bldg Sci, Beijing Key Lab Indoor Air Qual Evaluat & Control, Beijing 100084, Peoples R China
关键词
Dehumidification; Room air conditioner; Dehumidifier; Three -fluid heat exchanger; Building energy efficiency; PUMP DEHUMIDIFIER; PERFORMANCE; CONSUMPTION; SIMULATION; OPERATION;
D O I
10.1016/j.enconman.2022.116236
中图分类号
O414.1 [热力学];
学科分类号
摘要
Room air conditioners are unable to simultaneously control the temperature and humidity of the air supply. Although temperature-regulating dehumidifiers can simultaneously control the temperature and humidity, they have complex refrigerant pipelines, and the heat exchanger exhibits air resistance when the reheat demand is low. This study proposes an air conditioning system for simultaneous temperature and humidity control, using a three-fluid heat exchanger. The supply air temperature is adjusted by changing the air volume ratio and cooling water flow rate through the three-fluid heat exchanger, which is used as the condenser. Free cooling can be realized by supplying low-temperature cooling water to treat the return air. Numerical models were built to simulate the performance of the devices in the system, and were validated by experimental results. The temperature-regulating performance and energy consumption under different conditions were numerically calculated using a case-studied air-conditioned room in Beijing. The results are summarized as follows: 1. The proposed strategy can regulate the supply air temperature over a wide range of temperatures. 2. Compared with those of the temperature-regulating dehumidifier system, the compressor and fan energy consumption of the proposed system are reduced by 19.1% and 15.5%, respectively, with a total energy-saving rate of 15.8% in the cooling season. 3. Compared with those of the room air conditioner system, the compressor energy consumption of the proposed system is reduced by 11.5%, and the energy-saving rate of the entire system is 6.3%. The initial investment of the proposed system does not increase significantly compared with conventional systems, and the refrigerant pipeline and valves can be simplified, resulting in acceptable economic performance for the proposed system.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Energy-efficient air conditioning system with combination of radiant cooling and periodic total heat exchanger
    Yang, C. M.
    Chen, C. C.
    Chen, S. L.
    [J]. ENERGY, 2013, 59 : 467 - 477
  • [2] Numerical Investigation on three-fluid heat exchanger for hybrid Energy source heat pumps
    Zhang, Weijia
    Shao, Shuangquan
    Zhang, Hainan
    Tian, Changqing
    [J]. 8TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY (ICAE2016), 2017, 105 : 1692 - 1699
  • [3] ENERGY-EFFICIENT AIR-CONDITIONING SYSTEM
    SUENAGA, T
    [J]. JAPAN TELECOMMUNICATIONS REVIEW, 1986, 28 (03): : 217 - 224
  • [4] Effectiveness of Advanced Three-Fluid Heat and Mass Exchanger
    Gao, Zhiming
    Yang, Zhiyao
    Kumar, Navin
    Gluesenkamp, Kyle
    Abuheiba, Ahmad
    Baxter, Van D.
    [J]. ASHRAE TRANSACTIONS 2021, VOL 127, PT 2, 2021, 127 : 373 - 381
  • [5] Exergy Effectiveness Analysis of Three-Fluid Heat Exchanger
    Deng-Fang Ruan
    Xiao-Feng Yuan
    Shuang-Ying Wu
    You-Rong Li
    [J]. Journal of Superconductivity and Novel Magnetism, 2010, 23 : 1127 - 1131
  • [6] Exergy Effectiveness Analysis of Three-Fluid Heat Exchanger
    Ruan, Deng-Fang
    Yuan, Xiao-Feng
    Wu, Shuang-Ying
    Li, You-Rong
    [J]. JOURNAL OF SUPERCONDUCTIVITY AND NOVEL MAGNETISM, 2010, 23 (06) : 1127 - 1131
  • [7] Steady state of three-fluid parallel-flow heat exchanger system
    Chen, Jian-Hua
    Malinowski, Leszek
    [J]. JOURNAL OF ENGINEERING MATHEMATICS, 2014, 87 (01) : 153 - 165
  • [8] Steady state of three-fluid parallel-flow heat exchanger system
    Jian-Hua Chen
    Leszek Malinowski
    [J]. Journal of Engineering Mathematics, 2014, 87 : 153 - 165
  • [9] Heat Transfer Effectiveness of Three-Fluid Separated Heat Pipe Exchanger
    Shi, Chengming
    Wang, Yang
    Yang, Ying
    Liao, Quan
    [J]. JOURNAL OF THERMAL SCIENCE, 2011, 20 (01) : 64 - 69
  • [10] Heat Transfer Effectiveness of Three-Fluid Separated Heat Pipe Exchanger
    Chengming Shi
    [J]. Journal of Thermal Science, 2011, 20 (01) : 64 - 69