Validated LC-MS/MS Method for the Quantification of Ponatinib in Plasma: Application to Metabolic Stability

被引:29
|
作者
Kadi, Adnan A. [1 ]
Darwish, Hany W. [1 ,2 ]
Attwa, Mohamed W. [1 ,2 ]
Amer, Sawsan M. [2 ]
机构
[1] King Saud Univ, Coll Pharm, Dept Pharmaceut Chem, POB 2457, Riyadh 11451, Saudi Arabia
[2] Cairo Univ, Fac Pharm, Dept Analyt Chem, Cairo 11562, Egypt
来源
PLOS ONE | 2016年 / 11卷 / 10期
关键词
CHRONIC MYELOID-LEUKEMIA; BCR-ABL; DISCOVERY; INHIBITOR; AP24534; MUTANT;
D O I
10.1371/journal.pone.0164967
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
In the current work, a rapid, specific, sensitive and validated liquid chromatography tandem mass-spectrometric method was developed for the quantification of ponatinib (PNT) in human plasma and rat liver microsomes (RLMs) with its application to metabolic stability. Chromatographic separation of PNT and vandetanib (IS) were accomplished on Agilent eclipse plus C18 analytical column (50 mm x 2.1 mm, 1.8 mu m particle size) maintained at 21 +/- 2 degrees C. Flow rate was 0.25 mLmin(-1) with run time of 4 min. Mobile phase consisted of solvent A (10 mM ammonium formate, pH adjusted to 4.1 with formic acid) and solvent B (acetonitrile). Ions were generated by electrospray (ESI) and multiple reaction monitoring (MRM) was used as basis for quantification. The results revealed a linear calibration curve in the range of 5-400 ngmL(-1) (r(2) >= 0.9998) with lower limit of quantification (LOQ) and lower limit of detection (LOD) of 4.66 and 1.53 ngmL(-1) in plasma, 4.19 and 1.38 ngmL(-1) in RLMs. The intra-and inter-day precision and accuracy in plasma ranged from1.06 to 2.54% and -1.48 to -0.17, respectively. Whereas in RLMs ranged from 0.97 to 2.31% and -1.65 to -0.3%. The developed procedure was applied for quantification of PNT in human plasma and RLMs for study metabolic stability of PNT. PNT disappeared rapidly in the 1st 10 minutes of RLM incubation and the disappearance plateaued out for the rest of the incubation. In vitro half-life (t(1/2)) was 6.26 min and intrinsic clearance (CLin) was 15.182 +/- 0.477.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Investigation of the metabolic stability of olmutinib by validated LC-MS/MS: quantification in human plasma
    Attwa, Mohamed W.
    Kadi, Adnan A.
    Darwish, Hany W.
    Abdelhameed, Ali S.
    [J]. RSC ADVANCES, 2018, 8 (70): : 40387 - 40394
  • [2] A validated LC-MS/MS method for the rapid quantification of vilazodone in rat plasma: Application to a pharmacokinetic study
    Sui, Wenwen
    Yang, Xiaojing
    Yu, Wenhong
    Jin, Yi
    Luan, Xinyi
    Wang, Xiangjun
    Xu, Haiyan
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 98 : 228 - 234
  • [3] Validated LC-MS/MS method for quantification of agomelatine in human plasma and its application in a pharmacokinetic study
    Patil, Satish R.
    Nerurkar, Ketan K.
    Kalamkar, Ashok M.
    Pukale, Vishwas
    Mangaonkar, Kiran V.
    Pingale, Satish G.
    [J]. JOURNAL OF MASS SPECTROMETRY, 2012, 47 (01): : 23 - 28
  • [4] A validated LC-MS/MS method for the quantification of capivasertib in dog plasma: Application to its pharmacokinetics study
    Zhang, Zhe
    Nong, Li
    Chen, Meng-Lei
    Liu, Ming-Hui
    Cheng, Wen-Wu
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2020, 34 (10)
  • [5] An LC-MS/MS Validated Method for Quantification of Chlorzoxazone in Human Plasma and Its Application to a Bioequivalence Study
    He, Jiake
    Li, Ning
    Xu, Jiaqiu
    Zhu, Jing
    Yu, Yang
    Chen, Xijing
    Lu, Yang
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2019, 57 (08) : 751 - 757
  • [6] A Validated Bioanalytical Method for Quantification of Ziprasidone in Rabbit Plasma by LC-MS/MS: Application to a Pharmacokinetic Study
    Bhavyasri, Khagga
    Balaram, V. Murali
    Nageswarao, R.
    Rambabu, D.
    Ajitha, M.
    Challa, Bala Sekhara Reddy
    [J]. BRITISH JOURNAL OF PHARMACEUTICAL RESEARCH, 2015, 6 (05): : 322 - 332
  • [7] A validated method for quantitation of psilocin in plasma by LC-MS/MS and study of stability
    Martin, Rafaela
    Schuerenkamp, Jennifer
    Pfeiffer, Heidi
    Koehler, Helga
    [J]. INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 2012, 126 (06) : 845 - 849
  • [8] A validated LC-MS/MS analytical method for the quantification of pemigatinib: metabolic stability evaluation in human liver microsomes
    Attwa, Mohamed W.
    Abdelhameed, Ali S.
    Alsaif, Nawaf A.
    Kadi, Adnan A.
    AlRabiah, Haitham
    [J]. RSC ADVANCES, 2022, 12 (31) : 20387 - 20394
  • [9] Validated LC-MS/MS method for quantification of gabapentin in human plasma: application to pharmacokinetic and bioequivalence studies in Korean volunteers
    Park, Jin-Hee
    Jhee, Ok-Hwa
    Park, Song-Hee
    Lee, Jung-Sik
    Lee, Min-Ho
    Shaw, Leslie M.
    Kim, Kwang-Hyun
    Lee, Jong-Ho
    Kim, Yong-Seok
    Kang, Ju-Seop
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (08) : 829 - 835
  • [10] Validated LC-MS/MS method for the quantification of sciadopitysin in rat plasma and its application to pharmacokinetic and bioavailability studies in vivo
    Yang, Shengbao
    Qu, Ruiying
    Zhu, Zhe
    Li, Wei
    Zhao, Chengliang
    Li, Liantai
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2018, 32 (08)