A Comparison of Specific Absorption Rates in SAM Phantom and Child Head Models at 835 and 1900 MHz

被引:15
|
作者
Lee, Ae-Kyoung [1 ]
Yun, Jaehoon [1 ]
机构
[1] Elect & Telecommun Res Inst, Radio Technol Res Dept, Taejon 305350, South Korea
关键词
Cheek and tilt positions; children; compressed pinna; ear entrance canal (EEC); ear reference point (ERP); mobile phone; specific absorption rate (SAR); specific anthropomorphic mannequin (SAM) phantom; the finite-difference time-domain (FDTD) technique; ENERGY-ABSORPTION; NEAR-FIELD;
D O I
10.1109/TEMC.2010.2103364
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The specific absorption rates (SARs) in 7-year-old Korean, and 5- and 9-year-old European child head models were evaluated and compared with those of the specific anthropomorphic mannequin (SAM) phantom for mobile phone exposure at 835 and 1900 MHz. Compression of the pinnae was also considered for the 5- and 7-year-old child models during the evaluation. The cheek and tilt positions occurring when the earpiece of the phone is placed at the ear entrance canal (EEC) were analyzed against the same positions occurring when the earpiece is placed at the ear reference point (ERP). SAR variations were investigated for different skin and fat properties, as well as for different internal fat and muscle morphologies in the tissue area near the phone. A basic phone model with a monopole antenna was used for SAR calculation at each frequency. A phone model with a planar inverted F antenna was also used for verification, since the SAR results in the child models were higher than those in the SAM phantom at 1900 MHz. The spatial peak 10-g SAR values in all tissue including the pinnae and head-only were normalized to a forward power of 1 W at the feedpoint of the phone. Our results can be summarized as follows. First, a compressed pinna did not show significant changes in SAR values at 835 MHz; however, at 1900 MHz, there was an average 25% increase in spatial peak 10-g SARs for pinna-excluded tissue and a 29% increase for pinna-included tissue. Second, a phone earpiece placed at the EEC provided higher SARs in many cases compared to placement at the ERP. Third, the peak 10-g SAR was found to be very sensitive to the fat and muscle structure under the skin when touched by the mobile phone; a muscle-dominant internal head structure led to a higher peak 10-g SAR. Finally, the SAM phantom does not seem to provide a conservative estimation of child head exposure at 1900 MHz; 45% (pinna-excluded: IEEE Std C95.1) and 75% (pinna-included: ICNIRP guidelines) of the 40 total cases we reviewed showed higher SAR results than the SAM phantom.
引用
收藏
页码:619 / 627
页数:9
相关论文
共 50 条
  • [1] Electromagnetic absorption in the human head and neck for mobile telephones at 835 and 1900 MHz
    Gandhi, OP
    Lazzi, G
    Furse, CM
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1996, 44 (10) : 1884 - 1897
  • [2] The scaled SAM models and SAR for handset exposure at 835 MHz
    Lee, AK
    Choi, HD
    Choi, JI
    Pack, JK
    [J]. 2005 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM, VOLS 1-4, 2005, : 1323 - 1326
  • [3] Evaluation of Specific Absorption Rates with High Resolution Human Head Models at 890 MHz
    Kozlov, M.
    Weiskopf, N.
    Moeller, H. E.
    [J]. 2018 IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION & USNC/URSI NATIONAL RADIO SCIENCE MEETING, 2018, : 903 - 904
  • [4] Study on SARs in head models with different shapes by age using SAM model for mobile phone exposure at 835 MHz
    Lee, Ae-Kyoung
    Choi, Hyung-Do
    Choi, Jae-Ick
    [J]. IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2007, 49 (02) : 302 - 312
  • [5] Conservativeness of the SAM Phantom for the SAR Evaluation in the Child's Head
    Monebhurrun, Vikass
    [J]. IEEE TRANSACTIONS ON MAGNETICS, 2010, 46 (08) : 3477 - 3480
  • [6] Specific absorption rate values of handsets in cheek position at 835 MHz as a function of scaled specific anthropomorphic mannequin models
    Lee, AK
    Choi, HD
    Choi, JI
    Pack, JK
    [J]. ETRI JOURNAL, 2005, 27 (02) : 227 - 230
  • [7] Some present problems and a proposed experimental phantom for SAR compliance testing of cellular telephones at 835 and 1900 MHz
    Gandhi, OP
    Kang, G
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (09): : 1501 - 1518
  • [8] SAR Comparison of SAM Phantom and Anatomical Head Models for a Typical Bar-Type Phone Model
    Lee, Ae-Kyoung
    Hong, Seon-Eui
    Kwon, Jong-Hwa
    Choi, Hyung-Do
    [J]. IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2015, 57 (05) : 1281 - 1284
  • [9] Effects of metallic objects on specific absorption rate in the human head for 915 and 1900 MHz mobile phones
    Yelkenci, Tanju
    [J]. FREQUENZ, 2006, 60 (3-4) : 46 - 49
  • [10] Effects of ear-connection modeling on the electromagnetic-energy absorption in a human-head phantom exposed to a dipole antenna field at 835 MHz
    Kanda, M
    Balzano, Q
    Russo, P
    Faraone, A
    Bit-Babik, G
    [J]. IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2002, 44 (01) : 4 - 10