The Twister laser fiber degradation and tissue ablation capability during 980-nm high-power diode laser ablation of the prostate. A randomized study versus the standard side-firing fiber

被引:16
|
作者
Shaker, Hassan [1 ]
Alokda, Alsayed [2 ]
Mahmoud, Hisham [3 ]
机构
[1] Ain Shams Univ, Dept Urol, Cairo, Egypt
[2] Ain Shams Univ, Dept Occupat Hlth & Environm, Cairo, Egypt
[3] Cairo Univ, Natl Inst Laser Sci, Cairo, Egypt
关键词
Lasers; Diode lasers; Benign prostatic hyperplasia (BPH); Equipment failure analysis; PHOTOSELECTIVE VAPORIZATION; HYPERPLASIA; NM; KIDNEYS;
D O I
10.1007/s10103-011-1017-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The objective of this work is to test the ablation capability and fiber degradation of the novel Twister fibers (TW), in both the large (LTW) and the standard (STW) sizes, against the standard side-firing (SF) fiber in a clinical setting during the treatment of BPH patients using the 980-nm high-power diode laser (HPDL). One hundred and twenty BPH patients treated with HPDL (Ceralase300, Biolitec AG, Jena, Germany) were randomized to receive treatment by one of the three fibers. Operative time corrected to tissue volume, laser treatment time, and laser energy were measured. Ablation rate was calculated as follows: the decrease of the prostate volume after 6 months/laser time. The fibers' resistance to degradation was defined by the laser energy needed to degrade the fiber completely. Preoperative prostate volume of 76 +/- 38, 70 +/- 39, and 88 +/- 49 cc decreased by 49 +/- 16, 51 +/- 20, and 63 +/- 16% for the SF, STW, and LTW fibers, respectively. This difference was highly significant when the LTW was compared to the other two fibers (p < 0.001). Prostate volume reduction post-operatively within each group as compared to the pre-operative volume was highly significant (p < 0.001). The ablation rate was highest in LTW, being 1.31 +/- 0.59, 1.09 +/- 0.51, and 1.54 +/- 0.44 cc/min for the SF, STW, and LTW fibers, respectively. The LTW fiber resisted degradation more than the other fibers and the STW more than the SF fiber (p < 0.001). This study demonstrates the higher ablation efficiency and resistance to degradation of the LTW fiber as compared to the STW and SF fibers. The STW fiber has a similar ablation rate of the SF fiber but resists degradation better.
引用
收藏
页码:959 / 963
页数:5
相关论文
共 14 条
  • [1] The Twister laser fiber degradation and tissue ablation capability during 980-nm high-power diode laser ablation of the prostate. A randomized study versus the standard side-firing fiber
    Hassan Shaker
    Alsayed Alokda
    Hisham Mahmoud
    Lasers in Medical Science, 2012, 27 : 959 - 963
  • [2] TWISTER LASER FIBER INCREASES THE EFFICIENCY OF THE 980 NM DIODE LASER PROSTATECTOMY. A RANDOMIZED PROSPECTIVE TRIAL OF THE TWISTER FIBER VERSUS THE SIDE FIRING FIBER
    Shaker, H. S.
    Shaker, S. H.
    EUROPEAN UROLOGY SUPPLEMENTS, 2011, 10 (02) : 153 - 153
  • [4] Side-firing fiber for underwater tissue ablation with erbium laser radiation
    Konz, F
    Fohn, O
    Pratisto, H
    Frenz, M
    Weber, HP
    LASER-TISSUE INTERACTION VII, PROCEEDINGS OF, 1996, 2681 : 226 - 232
  • [5] Quartz Head Contact Laser Fiber: A Novel Fiber for Laser Ablation of the Prostate Using the 980 nm High Power Diode Laser
    Shaker, Hassan S.
    Shoeb, Mohammed S.
    Yassin, Mohammed M.
    Shaker, Sayed H.
    JOURNAL OF UROLOGY, 2012, 187 (02): : 575 - 579
  • [6] 980-nm random fiber laser directly pumped by a high-power 938-nm laser diode
    Babin, Sergey A.
    Dontsova, Ekaterina I.
    Kablukov, Sergey I.
    FIBER LASERS XI: TECHNOLOGY, SYSTEMS, AND APPLICATIONS, 2014, 8961
  • [7] High-power thulium fiber laser ablation of the canine prostate
    Fried, NM
    Murray, KE
    Photonic Therapeutics and Diagnostics, 2005, 5686 : 176 - 182
  • [8] SIDE-FIRING FIBER DEVICE FOR UNDERWATER TISSUE ABLATION WITH HO:YAG AND ER:YAG LASER RADIATION
    Foehn, Oliver
    Pratisto, Hans S.
    Koenz, Flurin
    Ith, Michael
    Altermatt, Hans J.
    Frenz, Martin
    Weber, Heinz P.
    JOURNAL OF BIOMEDICAL OPTICS, 1998, 3 (01) : 112 - 122
  • [9] High-power 980-nm pump laser modules for erbium-doped fiber amplifiers
    Achtenhagen, M
    McElhinney, M
    Nolan, S
    Hardy, A
    APPLIED OPTICS, 1999, 38 (27) : 5765 - 5767
  • [10] 980-Nm Diode Laser Vaporization versus Transurethral Resection of the Prostate for Benign Prostatic Hyperplasia: Randomized Controlled Study
    Cetinkaya, Mehmet
    Onem, Kadir
    Rifaioglu, Mehmet Murat
    Yalcin, Veli
    UROLOGY JOURNAL, 2015, 12 (05) : 2355 - 2361