Seismic Response of Adjacent Structures Connected with Semi-Active Variable Friction Dampers

被引:0
|
作者
Patel, Chiragbhai Chandubhai [1 ]
Jangid, Radhey Shyam [1 ]
机构
[1] Indian Inst Technol, Dept Civil Engn, Bombay 400076, Maharashtra, India
来源
关键词
OF-THE-ART; MODAL CONTROL; CONTROLLER; SYSTEMS;
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In this paper, the responses of two adjacent structures connected with semi active variable friction dampers (SAVFD) under various earthquake excitations are investigated. By controlling the clamping force, SAVFD is able to adjust its slip force and remain in slip state during an earthquake of arbitrary intensity. The objective of this study is to evaluate the optimum value of the gain multiplier and its importance in the structural response reduction of coupled structures. The optimum gain multiplier, defined as the ratio of damper force to critical damper control force, is investigated for the SAVFD connected, adjacent structures subjected to four different types of earthquake ground motions. A numerical study is carried out for two adjacent, multi-degree-of-freedoms (MDOF) structures connected with SAVFD. The investigation is also carried out to determine the effectiveness of dampers in terms of the reduction of structural responses namely, displacement, acceleration, and shear forces of adjacent, connected structures. In addition, to minimize the cost of the dampers, the study is conducted with only 50 percent of total dampers at optimal locations, rather than placing the dampers at all floor levels. The predictive control with direct output feedback concept is considered, and the results are compared with uncontrolled and passive control cases. Results show that by using SAVFD to connect the adjacent structures of different fundamental frequencies, earthquake-induced responses of either structure can be effectively reduced. Further, it is observed that two adjacent MDOF structures connected with 50 percent of the total dampers at proper locations reduces earthquake induced responses as much as when they are connected at all floor levels; thus, the cost of the dampers can be significantly reduced.
引用
收藏
页码:39 / 46
页数:8
相关论文
共 50 条
  • [1] Semi-active modal control for seismic structures with variable friction dampers
    Lu, LY
    ENGINEERING STRUCTURES, 2004, 26 (04) : 437 - 454
  • [2] Semi-active friction dampers for seismic control of structures
    Kori, Jagadish G.
    Jangid, R. S.
    SMART STRUCTURES AND SYSTEMS, 2008, 4 (04) : 493 - 515
  • [3] Predictive control of seismic structures with semi-active friction dampers
    Lu, LY
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2004, 33 (05): : 647 - 668
  • [4] Seismic Response of Torsionally Coupled System with Semi-Active Variable Dampers
    Mevada, Snehal V.
    Jangid, R. S.
    JOURNAL OF EARTHQUAKE ENGINEERING, 2012, 16 (07) : 1043 - 1054
  • [5] Seismic response of adjacent buildings connected with friction dampers
    Bhaskararao, A. V.
    Jangid, R. S.
    BULLETIN OF EARTHQUAKE ENGINEERING, 2006, 4 (01) : 43 - 64
  • [6] Seismic Response of Adjacent Buildings Connected with Friction Dampers
    A. V. Bhaskararao
    R. S. Jangid
    Bulletin of Earthquake Engineering, 2006, 4 : 43 - 64
  • [7] Control of building seismic response by means of three semi-active friction dampers
    Stammers, CW
    Sireteanu, T
    JOURNAL OF SOUND AND VIBRATION, 2000, 237 (05) : 745 - 759
  • [8] Seismic response control of a complex structure using semi-active friction dampers
    Ng, CL
    Xu, YL
    SMART STRUCTURES AND MATERIALS 2004: SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS, 2004, 5391 : 177 - 188
  • [9] SEMI-ACTIVE MR DAMPERS FOR SEISMIC CONTROL OF STRUCTURES
    Kori, Jagadish G.
    Jangid, R. S.
    BULLETIN OF THE NEW ZEALAND SOCIETY FOR EARTHQUAKE ENGINEERING, 2009, 42 (03): : 157 - 166
  • [10] Semi-active stiffness dampers for seismic control of structures
    Kori, Jagadish G.
    Jangid, R. S.
    ADVANCES IN STRUCTURAL ENGINEERING, 2007, 10 (05) : 501 - 524