In Vivo Testing of Knee Stability After Rotating-hinge Total Knee Arthroplasty: A Comparison of 2 Knee Systems

被引:2
|
作者
Friesenbichler, Joerg [1 ]
Glehr, Mathias [1 ]
Sadoghi, Patrick [1 ]
Maurer-Ertl, Werner [1 ]
Ott, Florian [1 ]
Leithner, Andreas [1 ]
机构
[1] Med Univ Graz, Dept Orthopaed Surg, A-8036 Graz, Austria
关键词
ENDOPROSTHETIC RECONSTRUCTIONS; TUMOR ENDOPROSTHESES; LIMB SALVAGE; BONE SARCOMA; FOLLOW-UP; MALIGNANT-TUMORS; REVISION SURGERY; PROXIMAL TIBIA; DISTAL FEMUR; REPLACEMENT;
D O I
10.3928/01477447-20120222-20
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Rotating-hinge knee prostheses are used for reconstruction in cases of severe articular compromise and major bone loss. Biomechanical studies revealed that rotating-hinge designs with long and cylindrical pegs are more stable than devices with short and more tapered ones. Twenty-five patients underwent clinical examination using ultrasound, radiographs, and 3 different rating systems to examine the in vivo stability and functional outcome of 2 rotating-hinge knee systems. Overall, the study revealed that a stable reconstruction could be achieved with both tested devices, with good functional outcome. The results for medial and lateral liftoff during flexion and extension in ultrasonography were comparable, whereas the measured distraction of the Limb Preservation System (LPS/M.B.T.; DePuy, Warsaw, Indiana) was lower compared with the S-ROM Noiles prostheses (DePuy). The implant, the new formed capsule, and the remaining soft tissues have to maintain joint stability. Soft tissue reconstruction, especially the medial gastrocnemius flap, and the newly formed periprosthetic scar seems to prevent distraction of several millimeters. In addition, determining the lift-off with ultrasonography showed that the shape of the peg does not influence implant's stability against lateral directed forces.
引用
收藏
页码:E335 / E342
页数:8
相关论文
共 50 条
  • [21] Rise of the rotating hinge in revision total knee arthroplasty
    Barrack, RL
    ORTHOPEDICS, 2002, 25 (10) : 1020 - +
  • [22] Serum metal ion levels after rotating-hinge knee arthroplasty: comparison between a standard device and a megaprosthesis
    Joerg Friesenbichler
    Werner Maurer-Ertl
    Patrick Sadoghi
    Thomas Lovse
    Reinhard Windhager
    Andreas Leithner
    International Orthopaedics, 2012, 36 : 539 - 544
  • [23] The effects of the rotating-hinge total knee replacement on gait and stair stepping
    Draganich, LF
    Whitehurst, JB
    Chou, LS
    Piotrowski, GA
    Pottenger, LA
    Finn, HA
    JOURNAL OF ARTHROPLASTY, 1999, 14 (06): : 743 - 755
  • [24] Clinical outcomes of primary rotating-hinge knee arthroplasty for knees with severe deformity
    Zhang Fujiang
    Liu Yabin
    Xiao Yu
    Liu Wenbin
    CHINESE MEDICAL JOURNAL, 2014, 127 (09) : 1791 - 1793
  • [25] Serum metal ion levels after rotating-hinge knee arthroplasty: comparison between a standard device and a megaprosthesis
    Friesenbichler, Joerg
    Maurer-Ertl, Werner
    Sadoghi, Patrick
    Lovse, Thomas
    Windhager, Reinhard
    Leithner, Andreas
    INTERNATIONAL ORTHOPAEDICS, 2012, 36 (03) : 539 - 544
  • [26] Revision Total Knee Arthroplasty With a Rotating-Hinge Prosthesis Mated to a Well-Fixed Femoral Sleeve
    Hannon, Charles P.
    Stuart, Michael B.
    Abdel, Matthew P.
    Pagnano, Mark W.
    Trousdale, Robert T.
    JOURNAL OF ARTHROPLASTY, 2022, 37 (06): : S270 - S275
  • [27] Mid-term results of complex primary total knee arthroplasty using a rotating-hinge implant
    Spranz, David M.
    Koch, Kevin-Arno
    Reiner, Tobias
    Hetto, Pit
    Gotterbarm, Tobias
    Merle, Christian
    KNEE, 2022, 34 : 34 - 41
  • [28] Clinical outcomes of primary rotating-hinge knee arthroplasty for knees with severe deformity
    Zhang Fujiang
    Liu Yabin
    Xiao Yu
    Liu Wenbin
    中华医学杂志(英文版), 2014, (09) : 1791 - 1793
  • [29] Dislocation of rotating-hinge knee prostheses with antidislocation mechanism
    Pacha-Vicente, Daniel
    Malik, Amer
    Castellet-Feliu, Enric
    Nardi-Vilardaga, Joan
    JOURNAL OF ARTHROPLASTY, 2008, 23 (02): : 299 - 303
  • [30] Risk Factors for Aseptic Loosening After Total Knee Arthroplasty with a Rotating-Hinge Implant A Case-Control Study
    Levent, Ali
    Suero, Eduardo M.
    Gehrke, Thorsten
    Citak, Mustafa
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2021, 103 (06): : 517 - 523