Design and optimization of cantilever based piezoelectric micro power generator for cardiac pacemaker

被引:26
|
作者
Alrashdan, Mohd H. S. [1 ]
Hamzah, Azrul Azlan [1 ]
Majlis, BurhanuddinYeop [1 ]
机构
[1] Univ Kebangsaan Malaysia, Inst Microengn & Nanoelect IMEN, Bangi 43600, Selangor, Malaysia
关键词
ENERGY; VIBRATIONS;
D O I
10.1007/s00542-014-2334-1
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Piezoelectric micro-power generator (PMPG) converts mechanical vibration energy into electric energy via piezoelectric effects. In cardiac pace makers, the use of PMPG eliminates the need for a traditional lithium iodide battery replacement. In this paper we design and optimize PMPG that is able to harvest the mechanical movement of the heart beat to be converted into usable electrical power in frequency range 1-1.7 Hz. Eight control parameters are selected: which are proof mass material, piezoelectric material, proof mass length, proof mass thickness, piezoelectric layer width, piezoelectric layer thickness, silicon nitride layer width, silicon nitride layer thickness. Orthogonal arrays of Taguchi method for these eight parameters mentioned with three levels and signal-to-noise (S/N) ratio, and ANOVA analysis is studied to determine the optimum design. COMSOL Multiphysics ver. 4.2 is used in 18 different simulations. The maximum output power and highest efficiency designed at 1.2 Hz is equivalent to 72 beat per min. Both Taguchi and ANOVA confirms the same results of determining the parameter of having the most influence on the generated output power at 1.2 Hz in descending order: which are piezoelectric material of PZT-5A, proof mass length of 5 mm, piezoelectric layer thickness of 30 A mu m, proof mass thickness of 4 mm, piezoelectric layer width of 0.12 mm, silicon nitride layer width of 0.16 mm, silicon nitride layer thickness of 30 A mu m, and proof mass material of aluminum. Eigen frequency analysis for the first six modes of operation for PMPG frequencies are: 1.2 HZ, 5.4 Hz, 6.9 Hz, 29,7 Hz, 694.8 Hz, 708.3 Hz. The first mode of operation is selected as operation mode and shows that 93 % of PMPG's total displacement and output power was produced in the range of 1-1.4 Hz, therefore PMPG can work when the heart rate between 60 and 84 bpm. Transient analysis performed at 1.2 Hz reaches the steady state before the first 10 cycles with output power density of 23.13 A mu W/cm(3), which is suitable for powering cardiac pace maker.
引用
收藏
页码:1607 / 1617
页数:11
相关论文
共 50 条
  • [1] Design and optimization of cantilever based piezoelectric micro power generator for cardiac pacemaker
    Mohd H. S. Alrashdan
    Azrul Azlan Hamzah
    BurhanuddinYeop Majlis
    [J]. Microsystem Technologies, 2015, 21 : 1607 - 1617
  • [2] Optimal design of piezoelectric cantilever for a micro power generator with microbubble
    Kang, JY
    Kim, HJ
    Kim, JS
    Kim, TS
    [J]. 2ND ANNUAL INTERNATIONAL IEEE-EMBS SPECIAL TOPIC CONFERENCE ON MICROTECHNOLOGIES IN MEDICINE & BIOLOGY, PROCEEDINGS, 2002, : 424 - 427
  • [3] Optimal design of piezoelectric cantilever for micro power
    Zhang, Hai Fang
    Xie, Qing Sheng
    Qin, Chong
    Cai, Lu
    [J]. PROCEEDINGS OF E-ENGDET2006, 2006, : 300 - 303
  • [4] Structural design and simulation analysis of a micro-silicon-based piezoelectric cantilever generator
    Du Xiaozhen
    Zeng Xiangwei
    Wang Gang
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART N-JOURNAL OF NANOMATERIALS NANOENGINEERING AND NANOSYSTEMS, 2015, 229 (04) : 196 - 200
  • [5] NUMERICAL OPTIMIZATION OF THE CANTILEVER PIEZOELECTRIC GENERATOR
    Soloviev, A. N.
    Chebanenko, V. A.
    Zhilyaev, I., V
    Cherpakov, A., V
    Parinov, I. A.
    [J]. MATERIALS PHYSICS AND MECHANICS, 2020, 44 (01): : 94 - 102
  • [6] Modeling and optimization of frequency tunable piezoelectric micro power generator
    Alrashdan, Mohd H. S.
    Ahmed, Mohammad Zayed
    Abu-Al-Aish, Amir
    [J]. Micro and Nanosystems, 2017, 9 (02) : 127 - 133
  • [7] Design and optimization of a wideband impact mode piezoelectric power generator
    Basari, A. A.
    Hashimoto, S.
    Homma, B.
    Okada, H.
    Okuno, H.
    Kumagai, S.
    [J]. CERAMICS INTERNATIONAL, 2016, 42 (06) : 6962 - 6968
  • [8] Design and Simulation of Micro-power Generator based on Piezoelectric Effect for MEMS Devices Applications
    Chou, Xiujian
    Zhang, Yating
    Guo, Maoxiang
    Guo, Tao
    Xiong, Jijun
    [J]. MICRO-NANO TECHNOLOGY XIII, 2012, 503 : 369 - 374
  • [9] Power Optimization Configuration for Piezoelectric Cantilever Arrays
    Jing, Bong Yu
    Leong, Kok Swee
    [J]. 2017 INTERNATIONAL CONFERENCE ON MECHANICAL, AERONAUTICAL AND AUTOMOTIVE ENGINEERING (ICMAA 2017), 2017, 108
  • [10] The Design of Micro Vibration Generator Based on Piezoelectric with Wide Bandwidth
    Yu Hui-hui
    Wen Zhong-quan
    Wen Zhi-yu
    He Xue-feng
    [J]. ISTM/2009: 8TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-6, 2009, : 1797 - 1801