Computer simulation of the steady state currents at enzyme doped carbon paste electrodes

被引:7
|
作者
Ivanauskas, F
Kaunietis, I
Laurinavicius, V
Razumiene, J
Simkus, R
机构
[1] Inst Biochem, LT-08662 Vilnius, Lithuania
[2] Vilnius State Univ, Fac Math & Informat, LT-03225 Vilnius, Lithuania
关键词
reaction-diffusion; modelling; amperometric biosensors; carbon; PQQ-dependent dehydrogenase;
D O I
10.1007/s10910-005-5825-6
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The plate-gap model of porous enzyme doped electrode has been proposed and analyzed. It was suggested that reaction diffusion conditions in pores of bulk electrode resemble particular conditions in thin gap between parallel conducting plates. The model is based on the diffusion equations containing a nonlinear term related to the Michaelis-Menten kinetic of the enzymatic reaction inside gap. Steady state current was calculated for the wide range of given parameters and substrate concentrations. All dependences of current on substrate concentration were approximated by hyperbolas in order to obtain "apparent" parameters (maximal currents and apparent Michaelis constants) of modelled biosensors. Simple approximate relationships between given and apparent parameters were derived. The applicability of theoretical plate-gap model was tested for the case of carbon paste electrodes which were doped with PQQ - dependent glucose dehydrogenase. It was found, that soluble glucose dehydrogenase based biosensors exhibit characteristic features of the theoretical plate-gap biosensors.
引用
收藏
页码:355 / 366
页数:12
相关论文
共 50 条
  • [1] Computer simulation of the steady state currents at enzyme doped carbon paste electrodes
    F. Ivanauskas
    I. Kaunietis
    V. Laurinavičius
    J. Razumienė
    R. Šimkus
    [J]. Journal of Mathematical Chemistry, 2005, 38 : 355 - 366
  • [2] Simulation of steady state limiting currents at arrays of square electrodes
    Britz, Dieter
    Strutwolf, Joerg
    Osterby, Ole
    [J]. ELECTROCHIMICA ACTA, 2023, 462
  • [3] Acid stability of carbon paste enzyme electrodes
    Wang, Joseph
    Musameh, Mustafa
    Mo, Jian-Wei
    [J]. ANALYTICAL CHEMISTRY, 2006, 78 (19) : 7044 - 7047
  • [4] Rectangular electrodes: Simulation of accurate steady state currents and the behaviour of square electrode arrays
    Britz, Dieter
    Strutwolf, Joerg
    Osterby, Ole
    [J]. ELECTROCHIMICA ACTA, 2022, 404
  • [5] Iridium-dispersed carbon paste enzyme electrodes
    Wang, J
    Rivas, G
    Chicharro, M
    [J]. ELECTROANALYSIS, 1996, 8 (05) : 434 - 437
  • [6] IMMOBILIZED ENZYME CARBON PASTE ELECTRODES AS AMPEROMETRIC SENSORS
    LORENZO, E
    GONZALEZ, E
    PARIENTE, F
    HERNANDEZ, L
    [J]. ELECTROANALYSIS, 1991, 3 (4-5) : 319 - 323
  • [7] FILAR ELECTRODES - STEADY-STATE CURRENTS AND SPECTROELECTROCHEMISTRY AT TWIN INTERDIGITATED ELECTRODES
    SANDERSON, DG
    ANDERSON, LB
    [J]. ANALYTICAL CHEMISTRY, 1985, 57 (12) : 2388 - 2393
  • [8] INTERDIGITATED MICROBAND ELECTRODES - CHRONOAMPEROMETRY AND STEADY-STATE CURRENTS
    SEDDON, BJ
    GIRAULT, HH
    EDDOWES, MJ
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 266 (02): : 227 - 238
  • [9] STEADY-STATE CURRENTS TO CONICAL AND SPHERICAL SEGMENT ELECTRODES
    BARD, AJ
    MIRKIN, MV
    ZOSKI, CG
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 206 : 121 - ANYL
  • [10] CHARACTERIZATION OF MIXED ENZYME-MEDIATOR-CARBON PASTE ELECTRODES
    AMINE, A
    KAUFFMANN, JM
    GUILBAULT, GG
    BACHA, S
    [J]. ANALYTICAL LETTERS, 1993, 26 (07) : 1281 - 1299