A high-resolution non-invasive approach to quantify oxygen transport across the capillary fringe and within the underlying groundwater

被引:60
|
作者
Haberer, Christina M. [1 ]
Rolle, Massimo [1 ]
Liu, Sanheng [1 ]
Cirpka, Olaf A. [1 ]
Grathwohl, Peter [1 ]
机构
[1] Univ Tubingen, Ctr Appl Geosci, D-72076 Tubingen, Germany
关键词
Capillary fringe; Oxygen transport; Hydrodynamic dispersion; 2-D experiments; Fiber-optical sensor technique; POROUS-MEDIA; TRANSVERSE DISPERSION; SOLUTE TRANSPORT; MASS-TRANSFER; HYDRODYNAMIC DISPERSION; MISCIBLE DISPLACEMENT; DISSOLVED-OXYGEN; WATER SATURATION; SANDY SOIL; FLOW;
D O I
10.1016/j.jconhyd.2010.10.006
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Oxygen transport across the capillary fringe is relevant for many biogeochemical processes. We present a non-invasive technique, based on optode technology, to measure high-resolution concentration profiles of oxygen across the unsaturated/saturated interface. By conducting a series of quasi two-dimensional flow-through laboratory experiments, we show that vertical hydrodynamic dispersion in the water-saturated part of the capillary fringe is the process limiting the mass transfer of oxygen. A number of experimental conditions were tested in order to investigate the influence of grain size and horizontal flow velocity on transverse vertical dispersion in the capillary fringe. In the same setup, analogous experiments were simultaneously carried out in the fully water-saturated zone, therefore allowing a direct comparison with oxygen transfer across the capillary fringe. The outcomes of the experiments under various conditions show that oxygen transport in the two zones of interest (i.e., the unsaturated/saturated interface and the saturated zone) is characterized by very similar transverse dispersion coefficients. An influence of the capillary fringe morphology on oxygen transport has not been observed. These results may be explained by the narrow grain size distribution used in the experiments, leading to a steep decline in water saturation at the unsaturated/saturated interface and to the absence of trapped gas in this transition zone. We also modeled flow (applying the van Genuchten and the Brooks-Corey relationships) and two-dimensional transport across the capillary fringe, obtaining simulated profiles of equivalent aqueous oxygen concentration that were in good agreement with the observations. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:26 / 39
页数:14
相关论文
共 50 条
  • [1] Characterization of Rock Samples by A High-Resolution Multi-Technique Non-Invasive Approach
    Fais, Silvana
    Cuccuru, Francesco
    Casula, Giuseppe
    Bianchi, Maria Giovanna
    Ligas, Paola
    MINERALS, 2019, 9 (11)
  • [2] Automated segmentation and fractal analysis of high-resolution non-invasive capillary perfusion maps of the human retina
    Jiang, Hong
    DeBuc, Delia Cabrera
    Rundek, Tatjana
    Lam, Byron L.
    Wright, Clinton B.
    Shen, Meixiao
    Tao, Aizhu
    Wang, Jianhua
    MICROVASCULAR RESEARCH, 2013, 89 : 172 - 175
  • [3] Photothermal Microimaging: A Non-Invasive and High-Resolution Imaging Technique
    Ding Jiayu
    Peng Siying
    LASER & OPTOELECTRONICS PROGRESS, 2023, 60 (22)
  • [4] Automated Segmentation and Multifractal Analysis of High-Resolution Non-Invasive Capillary Perfusion Maps (nCPMs) of the Human Retina
    Jiang, Hong
    DeBuc, Delia Cabrera
    Rundek, Tatjana
    Shen, Meixiao
    Lam, Byron
    Wang, Jianhua
    Shao, Yilei
    NEUROLOGY, 2013, 80
  • [5] Automated Segmentation and Multifractal Analysis of High-Resolution Non-Invasive Capillary Perfusion Maps (nCPMs) of the Human Retina
    Jiang, Hong
    DeBuc, Delia Cabrera
    Rundek, Tatjana
    Shen, Meixiao
    Lam, Byron
    Wang, Jianhua
    Shao, Yilei
    NEUROLOGY, 2013, 80
  • [6] Non-Invasive High-Resolution Imaging of In Vivo Human Myelinated Axons
    Lombardo, Marco
    Cesareo, Massimo
    Falsini, Benedetto
    Cusumano, Andrea
    DIAGNOSTICS, 2024, 14 (03)
  • [7] Non-Invasive Synchronized Spatially High-Resolution Wireless Body Area Network
    Ghoshdastider, Unmesh
    Viga, Reinhard
    Kraft, Michael
    2014 IEEE NINTH INTERNATIONAL CONFERENCE ON INTELLIGENT SENSORS, SENSOR NETWORKS AND INFORMATION PROCESSING (IEEE ISSNIP 2014), 2014,
  • [8] Dynamic imaging of ictal oscillations using non-invasive high-resolution EEG
    Yang, Lin
    Wilke, Christopher
    Brinkmann, Benjamin
    Worrell, Gregory A.
    He, Bin
    NEUROIMAGE, 2011, 56 (04) : 1908 - 1917
  • [9] Non-invasive imaging of neuroanatomical structures and neural activation with high-resolution MRI
    Herberholz, Jens
    Mishra, Subrata H.
    Uma, Divya
    Germann, Markus W.
    Edwards, Donald H.
    Potter, Kimberlee
    FRONTIERS IN BEHAVIORAL NEUROSCIENCE, 2011, 5
  • [10] Localized uncombable hair syndrome: Non-invasive imaging with high-resolution videodermoscopy
    Tognetti, Linda
    Pianigiani, Elisa
    Carraro, Andrea
    de Santi, Margherita
    Cinotti, Elisa
    Rubegni, Pietro
    SKIN RESEARCH AND TECHNOLOGY, 2021, 27 (04) : 648 - 651