Robust Ground Reaction Force Estimation and Control of Lower-Limb Prostheses: Theory and Simulation

被引:24
|
作者
Azimi, Vahid [1 ]
Nguyen, Thang Tien [2 ]
Sharifi, Mojtaba [3 ]
Fakoorian, Seyed Abolfazl [4 ]
Simon, Dan [4 ]
机构
[1] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
[2] Ton Duc Thang Univ, Modeling Evolutionary Algorithms Simulat & Artifi, Fac Elect & Elect Engn, Ho Chi Minh City, Vietnam
[3] Sharif Univ Technol, Dept Mech Engn, Tehran 1136511155, Iran
[4] Cleveland State Univ, Dept Elect Engn & Comp Sci, Cleveland, OH 44115 USA
关键词
Prosthetics; Legged locomotion; Uncertainty; Observers; Adaptation models; Adaptive control; estimation; prosthetics; robust control; sliding mode control; SLIDING-MODE OBSERVER; HUMAN GAIT; SYSTEMS; PATTERNS; DESIGN; ANKLE; ROBOT;
D O I
10.1109/TSMC.2018.2836913
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Ground reaction force (GRF) characteristics of amputee walking are important for the analysis of clinical gait data, and also to update model reference adaptive impedance (MRAI) controllers. GRF estimation is a better alternative than direct GRF measurement because of the disadvantages of load cells, such as high cost, integration difficulties due to weight and physical dimensions, the possibility of overload, and measurement noise. This paper presents four robust MRAI observer/controller combinations for GRF estimation-based control of a prosthesis and a legged robot model in the presence of parametric uncertainties and unmodeled dynamics, in which the robot model is employed to mimic able-bodied walking. Since unknown GRFs can reduce the performance of prosthesis control systems, the proposed MRAI controllers are designed to compensate their effects. All four proposed observer/controller combinations enable the system to imitate the biomechanics of able-bodied walking as defined by mechanical impedance, and provide flexible and smooth gait. Lyapunov analysis of the observer/controller combinations is used to prove stability. The four MRAI controllers are compared with each other from the perspective of GRF estimation accuracy, prosthetic knee angle tracking accuracy, parameter estimation accuracy, control effort, and computational effort. Simulation results show that all four MRAI controllers achieve good tracking performance, stable limit cycles, and accurate GRF estimation.
引用
收藏
页码:3024 / 3035
页数:12
相关论文
共 50 条
  • [1] Stable, Robust Hybrid Zero Dynamics Control of Powered Lower-Limb Prostheses
    Martin, Anne E.
    Gregg, Robert D.
    [J]. IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 2017, 62 (08) : 3930 - 3942
  • [2] Estimation of lower-limb sagittal joint moments during gait using vertical ground reaction force
    Inai T.
    Takabayashi T.
    [J]. Journal of Biomechanics, 2022, 145
  • [3] Development of an Active Force Plate for Testing Lower-Limb Prostheses
    Marinelli, Cristiano
    Giberti, Hermes
    Resta, Ferruccio
    [J]. ADVANCES IN ITALIAN MECHANISM SCIENCE, 2017, 47 : 61 - 70
  • [4] AMPUTATIONS AND PROSTHESES FOR THE LOWER-LIMB
    MARQUARDT, E
    CORRELL, J
    [J]. INTERNATIONAL ORTHOPAEDICS, 1984, 8 (02) : 139 - 146
  • [5] STANDARDS FOR LOWER-LIMB PROSTHESES
    WILSON, AB
    [J]. PROSTHETICS AND ORTHOTICS INTERNATIONAL, 1979, 3 (01) : 44 - 45
  • [6] Alignment of lower-limb prostheses
    Zahedi, M.S.
    Spence, W.D.
    Solomonidis, S.E.
    Paul, J.P.
    [J]. Journal of rehabilitation R&D, 1986, 23 (02): : 2 - 19
  • [7] USE AND USEFULNESS OF LOWER-LIMB PROSTHESES
    BUIJK, CA
    [J]. INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 1988, 11 (04) : 361 - 367
  • [8] BIOMECHANICS OF LOWER-LIMB PROSTHESES IN AGED
    BAUMANN, JU
    RUEPP, R
    [J]. ORTHOPADE, 1978, 7 (02): : 106 - 109
  • [9] Estimation of Ground Reaction Forces Based on Knee Joint Acceleration of Lower-Limb Exoskeletons
    Hsiao, Tesheng
    Yip, Kinglam
    Chiu, Yun-Jen
    [J]. 2020 INTERNATIONAL AUTOMATIC CONTROL CONFERENCE (CACS), 2020,
  • [10] A method to determine the optimal features for control of a powered lower-limb prostheses
    Farrell, M. Todd
    Herr, Hugh
    [J]. 2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 6041 - 6046