Effects of operating parameters on the combustion of medical waste in a controlled air incinerator

被引:33
|
作者
Jangsawang, W
Fungtammasan, B
Kerdsuwan, S
机构
[1] Joint Grad Sch Energy & Environm, Bangkok 10140, Thailand
[2] King Mongkuts Inst Technol, Fac Engn, WIRC, Dept Engn Mech, Bangkok 10800, Thailand
关键词
medical waste; controlled air incinerator; optimum operating condition; primary chamber preheating temperature; batch size;
D O I
10.1016/j.enconman.2005.03.017
中图分类号
O414.1 [热力学];
学科分类号
摘要
Experiments have been performed to investigate the effects of primary chamber preheating temperature and batch size of the waste feed on the combustion of medical waste in a two chamber controlled air incinerator of 50 kg/h nominal capacity. The primary purpose is to determine qualitatively the functional relationships between the key incinerator performance indicators and the above two parameters so that optimum preheating conditions of a pilot incinerator, which has been in trial use at a hospital, may be defined. Three batch sizes were used, namely: 5, 7.5 and 10 kg, with the primary chamber preheating temperature varied from 500 to 800 degrees C at 100 degrees C intervals for each batch. The secondary chamber temperature control was set at 900 degrees C. The results showed that increasing the waste charging temperature and the weight of charge tend to accelerate the rate of volatile gas release, causing a "bottleneck effect" in the secondary chamber and, hence, a negative effect on the overall performance of the incinerator, as reflected in the residual unburned CO in the gases leaving the chamber. Higher charging rates could have been achieved by increasing the combustion air supplied to the chambers. Using CO measurement as a criterion for good combustion makes it possible to determine the optimum incinerator temperature control settings and operating conditions, as well as to assure continuous, efficient, environmentally satisfactory operation. The optimum operating condition for the range of experiments tested appears to be a batch size of 5 kg and a primary chamber preheating temperature in the vicinity of 700 degrees C. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3137 / 3149
页数:13
相关论文
共 50 条
  • [1] Experiment on low air ratio combustion of a medical waste incinerator
    Xie, Rong
    Lu, Jidong
    Li, Jie
    [J]. Huazhong Keji Daxue Xuebao (Ziran Kexue Ban)/Journal of Huazhong University of Science and Technology (Natural Science Edition), 2009, 37 (11): : 126 - 128
  • [2] Treatment of medical solid waste using an Air Flow controlled incinerator
    Van Tuyen Trinh
    Huu Tap Van
    Quang Huy Pham
    Minh Viet Trinh
    Ha Manh Bui
    [J]. POLISH JOURNAL OF CHEMICAL TECHNOLOGY, 2020, 22 (01) : 29 - 34
  • [3] Advantageous effects of low air ratio combustion in an advanced stoker-type waste incinerator
    Miyagoshi, Y
    Tatefuku, T
    Nishino, M
    Yokoyama, T
    Kadowaki, S
    [J]. WASTE MANAGEMENT IN JAPAN, 2004, : 155 - 164
  • [4] The effect of air distribution on the characteristics of waste combustion and NO generation in a grate incinerator
    Liu, Jun
    Xie, Zheng
    Guo, Bingyu
    Xu, Yingzhe
    Wang, Qiuhong
    Guo, Xinwei
    Bai, Li
    Long, Jisheng
    [J]. JOURNAL OF THE ENERGY INSTITUTE, 2024, 117
  • [5] CORROSION OF A WASTE INCINERATOR - EFFECTS OF DESIGN AND OPERATING-CONDITIONS
    POURBAIX, A
    [J]. WERKSTOFFE UND KORROSION-MATERIALS AND CORROSION, 1989, 40 (03): : 157 - 159
  • [6] Development of a waste incinerator based on high-temperature air combustion technology
    Tomohiro Denda
    Takashi Nakayama
    Shinya Kano
    [J]. Journal of Material Cycles and Waste Management, 2023, 25 : 3256 - 3269
  • [7] Numerical simulation on operating parameters of SNCR process in a municipal solid waste incinerator
    Hu, Zhifeng
    Jiang, Enchen
    Ma, Xiaoqian
    [J]. FUEL, 2019, 245 : 160 - 173
  • [8] Development of a waste incinerator based on high-temperature air combustion technology
    Denda, Tomohiro
    Nakayama, Takashi
    Kano, Shinya
    [J]. JOURNAL OF MATERIAL CYCLES AND WASTE MANAGEMENT, 2023, 25 (06) : 3256 - 3269
  • [9] ON PERMITTING A MEDICAL WASTE INCINERATOR
    MORSE, HN
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1991, 41 (08): : 1145 - 1145
  • [10] Effect of secondary air supply rate on the combustion of volatile gas in a controlled-air incinerator
    Jangsawang, W
    Vallikul, P
    Fungtammasan, B
    Kerdsuwan, S
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2005, 29 (06) : 549 - 556