Colorimetric characterisation of a HD-PDP device

被引:0
|
作者
Kutas, G [1 ]
Bodrogi, P [1 ]
机构
[1] Univ Veszprem, Dept Image Proc & Neurocomp, Colour & Multimedia Lab, H-8201 Veszprem, Hungary
关键词
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Colorimetric characterisation measurements were carried out on a 42" hi-h-definition Panasonic plasma display. Four generally applied mathematical colorimetric characterisation models were investigated from the point of view of colorimetric accuracy, based on the spectral measurement of 157 test colours: GOG, GOG including channel independence, GOG including black emission and sRGB. The model including black emission performed better than the model including channel interdependence. All models performed better than sRGB. The overall electro-optic transfer function was a power function similar to those of CRT monitors. This may result from a look-up table built-in the hardware of the device.
引用
收藏
页码:65 / 69
页数:5
相关论文
共 50 条
  • [1] 65 in Full-Spec HD PDP
    Kawahara, I.
    Okumura, S.
    Setoguchi, H.
    Taniguchi, H.
    Tsujita, Y.
    Murai, R.
    IDW/AD '05: PROCEEDINGS OF THE 12TH INTERNATIONAL DISPLAY WORKSHOPS IN CONJUNCTION WITH ASIA DISPLAY 2005, VOLS 1 AND 2, 2005, : 1503 - 1504
  • [2] 50-in. Full HD Shadow Mask PDP
    Fan Zhaowen
    Zhang, X.
    Wu, Z.
    Tu, Y.
    Yang, L. L.
    Wang, B. P.
    Zhang, Q.
    IDW'10: PROCEEDINGS OF THE 17TH INTERNATIONAL DISPLAY WORKSHOPS, VOLS 1-3, 2010, : 931 - 934
  • [3] Grid generator for novel PDP device
    Yang, L.L.
    Tu, Y.
    Dianzi Qijian/Journal of Electron Devices, 2001, 24 (01):
  • [4] Realization of high luminous efficacy with full HD AC PDP
    Whang, Ki-Woong
    Bae, Hyun Sook
    Jung, Hae Yoon
    Lim, Jong Keun
    2007 SID INTERNATIONAL SYMPOSIUM, DIGEST OF TECHNICAL PAPERS, VOL XXXVIII, BOOKS I AND II, 2007, 38 : 1526 - 1529
  • [6] World's First 42-in.1080p HD PDP
    Tachibana, H.
    Ogawa, K.
    Nakajima, T.
    Nakagawa, T.
    Fujitani, M.
    Sumida, K.
    IDW '07: PROCEEDINGS OF THE 14TH INTERNATIONAL DISPLAY WORKSHOPS, VOLS 1-3, 2007, : 2117 - 2120
  • [8] Effects of plasma loss on luminous efficacy in Full HD AC PDP
    Bae, H. S.
    Whang, K-W.
    IDW '07: PROCEEDINGS OF THE 14TH INTERNATIONAL DISPLAY WORKSHOPS, VOLS 1-3, 2007, : 823 - 826
  • [9] Spectral dependence of colorimetric characterisation of scanners
    Fashandi, Hossein
    Amirshahi, Seyed H.
    Tehran, Mohammad A.
    Kandi, Saideh G.
    COLORATION TECHNOLOGY, 2011, 127 (04) : 240 - 245
  • [10] Improvement of colorimetric device of spectrophotometer
    He, G.Q.
    Li, X.X.
    Fenxi Yiqi/Analytical Instrumentation, 2001, (01):