On-line fouling monitoring model of condenser in coal-fired power plants

被引:19
|
作者
Li, Jianlan [1 ]
Zhai, Zhaoyin [1 ]
Wang, Jizhou [1 ]
Huang, Shuhong [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Energy & Power Engn, Wuhan 430074, Peoples R China
关键词
Coal-fired power plant; Condenser; Fouling; On-line monitoring; All-condition model; PERFORMANCE EVALUATION; SEAWATER; EVAPORATOR; IMPACT;
D O I
10.1016/j.applthermaleng.2016.04.131
中图分类号
O414.1 [热力学];
学科分类号
摘要
The fouling of water side surfaces decreases the thermal effectiveness of the condenser and it is always one of operational focuses in coal-fired power plants. This study presents a comprehensive approach to realize the on-line fouling monitoring for the condenser in thermal power plants. Based on the operational mechanism and the coupling property, an all-condition mechanism model (ACMM) of coal-fired power plants is proposed to simulate coupling operating characters of systems. The simulation results of a 600 MW/16.7 MPa/560 degrees C/560 degrees C supercritical coal-fired power plant indicate that the model is of sufficient accuracy for performance calculations under different off-design conditions. An on-line fouling model of the condenser is presented according to simulation results of ACMM and on-line monitoring parameters from SIS system. For the fouling model, a correction as a function of the non-condensable gas is implemented to improve the accuracy of the condensation heat transfer resistance in the steam side of the condenser. The results of the on-line fouling monitoring in the field reveal that the fouling of the condenser increased with time and the fouling growth rates kept relative stable. Furthermore, this study also provided an alarm for the leakage fault in the condenser according to the abnormal fouling resistance tend. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:628 / 635
页数:8
相关论文
共 50 条
  • [1] Numerical model for on-condition monitoring of condenser in coal-fired power plants
    Medica-Viola, Vedran
    Pavkovic, Branimir
    Mrzljak, Vedran
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 117 : 912 - 923
  • [2] An integrated approach to online monitoring of fouling in coal-fired power plants
    Idem, Stephen A.
    HEAT TRANSFER ENGINEERING, 2007, 28 (02) : 73 - 75
  • [3] On-line Monitoring of Ash Fouling for Air Pre-Heaters in Coal-fired Power Plant Boiler
    Shi Yuanhao
    Wang Jingcheng
    Wen Jie
    2017 29TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2017, : 1386 - 1390
  • [4] Inferential sensor for on-line monitoring of ammonium bisulfate formation temperature in coal-fired power plants
    Si, Fengqi
    Romero, Carlos E.
    Yao, Zheng
    Xu, Zhigao
    Morey, Robert L.
    Liebowitz, Barry N.
    FUEL PROCESSING TECHNOLOGY, 2009, 90 (01) : 56 - 66
  • [5] Coal-Fired Power Plants
    Peter Pauls
    热力透平, 2004, (02) : 105 - 107
  • [6] On-line monitoring of ash fouling and soot-blowing optimization for convective heat exchanger in coal-fired power plant boiler
    Shi, Yuanhao
    Wang, Jingcheng
    Liu, Zhengfeng
    APPLIED THERMAL ENGINEERING, 2015, 78 : 39 - 50
  • [7] Coal-Fired Power Plants Alternative Petcoke Fired Power Plants
    Ozcelik, Ozlem
    Boran, Kurtulus
    JOURNAL OF POLYTECHNIC-POLITEKNIK DERGISI, 2016, 19 (04): : 531 - 535
  • [8] Coal ... Coal-fired power plants for the future
    Heyn, Klaus
    Brennstoff-Waerme-Kraft, 1999, 51 (5-6): : 18 - 24
  • [9] Fouling monitor helps TransAlta coal-fired plants
    不详
    POWER, 2001, 145 (01) : 14 - 14
  • [10] Coal-Fired Power Plants of Japan
    A. N. Tugov
    I. V. Artemeva
    Power Technology and Engineering, 2024, 58 (4) : 644 - 653