Depth Elemental Imaging of Forensic Samples by Confocal micro-XRF Method

被引:67
|
作者
Nakano, Kazuhiko [1 ]
Nishi, Chihiro [1 ]
Otsuki, Kazunori [2 ]
Nishiwaki, Yoshinori [2 ]
Tsuji, Kouichi [1 ]
机构
[1] Osaka City Univ, Grad Sch Engn, Sumiyoshi Ku, Osaka 5588585, Japan
[2] Hyogo Prefectural Police Headquarters Shimoyamate, Forens Sci Lab, Chuo Ku, Kobe, Hyogo 6508510, Japan
关键词
X-RAY-FLUORESCENCE; PLASMA-MASS SPECTROMETRY; ICP-MS; GLASS; SPECTROSCOPY; PIGMENTS;
D O I
10.1021/ac1033177
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Micro-XRF is a significant tool for the analysis of small regions. A micro-X-ray. beam can be created in the laboratory by various focusing X-ray optics. Previously, non-destructive 3D-XRF analysis had not been easy because of the high penetration of fluorescent X-rays emitted into the sample. A recently developed confocal micro-XRF technique combined with polycapillary X-ray lenses enables depth-selective analysis. In this paper, we applied a new tabletop confocal micro-XRF system to analyze several forensic samples, that is, multilayered automotive paint fragments and leather samples, for use in the criminaliztics. Elemental depth profiles and mapping images of forensic samples were successfully obtained by the confocal micro-XRF technique. Multilayered structures can be distinguished in forensic samples by their elemental depth profiles. However, it was found that some leather sheets exhibited heterogeneous distribution. To confirm the validity, the result of a conventional micro-XRF of the cross section was compared with that of the confocal micro-XRF. The results obtained by the confocal micro-XRF system were in approximate agreement with those obtained by the conventional micro-XRF. Elemental depth imaging was performed on the paint fragments and leather sheets to confirm the homogeneity of the respective layers of the sample. The depth images of the paint fragment showed homogeneous distribution in each layer expect for Fe and Zn. In contrast, several components in the leather sheets were predominantly localized.
引用
收藏
页码:3477 / 3483
页数:7
相关论文
共 50 条
  • [1] Elemental Depth Analysis of Corroded Paint-Coated Steel by Confocal Micro-XRF Method
    Nakano, Kazuhiko
    Akioka, Koji
    Doi, Takashi
    Arai, Masahiro
    Takabe, Hideki
    Tsuji, Kouichi
    [J]. ISIJ INTERNATIONAL, 2013, 53 (11) : 1953 - 1957
  • [2] Combined micro-XRF and TXRF methodology for quantitative elemental imaging of tissue samples
    Wrobel, Pawel M.
    Bala, Slawomir
    Czyzycki, Mateusz
    Golasik, Magdalena
    Librowski, Tadeusz
    Ostachowicz, Beata
    Piekoszewski, Wojciech
    Surowka, Artur
    Lankosz, Marek
    [J]. TALANTA, 2017, 162 : 654 - 659
  • [4] Depth-selective elemental imaging of microSD card by confocal micro XRF analysis
    Nakazawa, Takashi
    Tsuji, Kouichi
    [J]. X-RAY SPECTROMETRY, 2013, 42 (03) : 123 - 127
  • [5] Comparison of SEM-EDS, Micro-XRF and Confocal Micro-XRF for Electric Device Analysis
    Komatani, Shintaro
    Aoyama, Tomoki
    Nakazawa, Takashi
    Tsuji, Kouichi
    [J]. E-JOURNAL OF SURFACE SCIENCE AND NANOTECHNOLOGY, 2013, 11 : 133 - 137
  • [6] Simulation of layer measurement with confocal micro-XRF
    Huber, Christian
    Smolek, Stephan
    Streli, Christina
    [J]. X-RAY SPECTROMETRY, 2014, 43 (03) : 175 - 179
  • [7] Reasons of different colors in the ignimbrite lithology: Micro-XRF and confocal Raman spectrometry method
    Koralay, Tamer
    Kadioglu, Yusuf Kagan
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2008, 69 (03) : 947 - 955
  • [8] Depth Elemental Imaging during Corrosion of Hot-Dip Galvanized Steel Sheet by Confocal Micro XRF Analysis
    Akioka, Koji
    Doi, Takashi
    Mita, Shohei
    Matsuyama, Tsugufumi
    Tsuji, Kouichi
    [J]. ANALYTICAL SCIENCES, 2020, 36 (01) : 55 - 59
  • [9] Depth Elemental Imaging during Corrosion of Hot-Dip Galvanized Steel Sheet by Confocal Micro XRF Analysis
    Koji Akioka
    Takashi Doi
    Shohei Mita
    Tsugufumi Matsuyama
    Kouichi Tsuji
    [J]. Analytical Sciences, 2020, 36 : 55 - 59
  • [10] Comparison of two confocal micro-XRF spectrometers with different design aspects
    Smolek, S.
    Nakazawa, T.
    Tabe, A.
    Nakano, K.
    Tsuji, K.
    Streli, C.
    Wobrauschek, P.
    [J]. X-RAY SPECTROMETRY, 2014, 43 (02) : 93 - 101