600MW Steam Turbine Side Optimization Retrofitting Effect Analysis And Calculation Of Energy-saving Quantity

被引:0
|
作者
Yi Ruyang [1 ]
Shi Zhangming [2 ]
机构
[1] Cent South Univ, Sch Energy Sci & Engn, Changsha, Hunan, Peoples R China
[2] Cent South Univ, Hunan Res Ctr Energy Saving Evaluat Technol, Changsha, Hunan, Peoples R China
关键词
turbine; energy-saving; steam seal; heat consumption rate; energy saving quantity;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Currently, the government regards energy saving as a priority to pursuit a harmonious society. As for power companies, to reduce heat consumption and improve the cylinder efficiency of the turbine is the main task of controlling the cost of power generation. This paper describes the conditions before and after the qualification test of retrofitting a power plant turbine side, makes a comparison between the experimental data before and after, analyzes of the effect of retrofit, and provides the quantitative calculation This paper can work as a reference for similar energy-saving issues.
引用
收藏
页码:542 / 545
页数:4
相关论文
共 15 条
  • [1] Optimization Research on Nozzle Governing 600MW Steam Turbine Operation
    Li, Ling
    Xu, Jian-qun
    Li, Gang
    Zhou, Ke-yi
    Shi, Yong-feng
    [J]. 2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [2] Shaft Crack Analysis and Diagnosis for the 600MW Steam Turbine Generator
    Jiang Dongxiang
    Hong Liangyou
    Huang Qian
    [J]. DAMAGE ASSESSMENT OF STRUCTURES VIII, 2009, 413-414 : 591 - 598
  • [3] Optimization of Steam Governing Arrangement for 600MW Sub-critical Steam Turbine Unit
    Guo, Di
    Hu, Nian-su
    Wang, Jian-mei
    Huang, Mei
    Liu, Yong-hui
    Yi, Zhao-hui
    [J]. 2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [4] TORSIONAL VIBRATION ANALYSIS AND STRESS CALCULATION FOR THE FAULT 600MW STEAM TURBINE GENERATOR SHAFT SYSTEM
    Jiang, Dongxiang
    Hong, Liangyou
    Wang, Zheng
    Xie, Xiaorong
    [J]. PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, VOL 1, PTS A AND B, 2010, : 103 - 110
  • [5] Analysis and treatment of abnormal increase of bearing temperature of 600MW steam turbine
    Ma, Lyuzhou
    [J]. 2020 6TH INTERNATIONAL CONFERENCE ON ENERGY, ENVIRONMENT AND MATERIALS SCIENCE, 2020, 585
  • [6] The numerical simulation of the shell side flow and heat transfer for 600MW steam turbine condenser
    Wang, Siping
    Zhang, Li
    Li, Jian
    [J]. ADVANCES IN POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2013, 614-615 : 265 - 271
  • [7] Thermal Stress Analysis of 600MW Steam Turbine Rotor in Different Governing Modes
    Li, Yong
    Sun, Haoran
    Nie, Yuhuo
    [J]. 2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [8] ANALYSIS OF HIGH TEMPERATURE CREEP ON THE NUT CONNECTION COMPONENTS OF A 600MW SUPERCRITICAL STEAM TURBINE
    Jiang, P. N.
    Wang, W. Z.
    Jiao, G. C.
    [J]. PROCEEDINGS OF THE ASME TURBO EXPO 2012, VOL 5, 2012, : 145 - 151
  • [9] Analysis on Shaft Torsion Response of 600MW Steam Turbine Unit Under Quick Load Regulation
    An Hong-wen
    Ma Zhi-yong
    Li Zhuang
    Zhong Cai-mao
    Liu Yang
    [J]. 26TH CHINESE CONTROL AND DECISION CONFERENCE (2014 CCDC), 2014, : 204 - 208
  • [10] STRENGTH AND RIGID ANALYSIS FOR EXHAUST EQUIPMENT OF 600MW SUPERCRITICAL DIRECT AIR-COOLING STEAM TURBINE
    Sun, Qing
    Wang, Xiu-jin
    Chen, Hong-xi
    Liu, Feng-zhen
    [J]. PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON POWER ENGINEERING 2009 (ICOPE-09), VOL 3, 2009, : 375 - 379