Design and simulation of neutron optical devices plus flight tube for neutron radiography

被引:1
|
作者
Schillinger, B [1 ]
Bleuel, M [1 ]
Böni, P [1 ]
Steichele, E [1 ]
机构
[1] Tech Univ Munich, Phys Dept E21, D-85747 Garching, Germany
关键词
neutron beams; neutron guides; neutron radiography;
D O I
10.1109/TNS.2005.843691
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The new reactor FRM-II from the Technische Universitat Munchen will offer a professional radiography and tomography facility for industrial use. It consists of a classical setup of diaphragm plus flight tube at the cold source, with unprecedented flux and geometric resolution. However, the original plans were to set it up at a neutron guide; many other facilities also only have space for a neutron radiography setup at a neutron guide. We have therefore examined several possibilities to perform neutron radiography and tomography at a guide system plus flight tube arrangement using a straight guide, an S-bender, a diverging guide or trumpet, and a converging guide plus flight tube.
引用
收藏
页码:404 / 409
页数:6
相关论文
共 50 条
  • [1] Simulation design of the collimator for thermal neutron radiography facility based on neutron tube
    Li, Huanyu
    Zhao, Chenyi
    Qiao, Shuang
    Zhang, Tian
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 985 (985):
  • [2] Simulation of fast neutron radiography with a Time-of-Flight system
    Chen, D.
    Bao, J.
    Zhang, Q.
    Han, S.
    Ren, J.
    Nie, Y.
    Ruan, X.
    Hou, L.
    PROCEEDINGS OF THE 10TH WORLD CONFERENCE ON NEUTRON RADIOGRAPHY (WCNR-10), 2015, 69 : 284 - 291
  • [3] Design of a mobile neutron radiography installation based on a compact sealed tube neutron generator
    Ma Wei Chao 1
    2Department of Physics
    Nuclear Science and Techniques, 1997, (01) : 53 - 55
  • [4] Simulation of neutron radiograph images at the Neutron Radiography Reactor
    Morgan, Sarah W.
    King, Jeffrey C.
    Pope, Chad L.
    ANNALS OF NUCLEAR ENERGY, 2013, 57 : 341 - 349
  • [5] Simulation and experiment of neutron radiography
    Institute of Nuclear Physics and Chemistry, CAEP, P.O. Box 919-211, Mianyang 621900, China
    Qiangjiguang Yu Lizishu, 2007, 7 (1229-1232):
  • [6] Evaluation of pyrotechnic devices by neutron radiography
    Subbiah, C
    Rao, KV
    Viswanathan, K
    Athithan, SK
    TRENDS IN NDE SCIENCE AND TECHNOLOGY - PROCEEDINGS OF THE 14TH WORLD CONFERENCE ON NDT (14TH WCNDT), VOLS 1-5, 1996, : 1461 - 1464
  • [7] Design and simulation of time-of-flight neutron reflectometer
    Li Xinxi
    Wang Yan
    Huang Chaoqiang
    Chen Bo
    NUCLEAR SCIENCE AND TECHNIQUES, 2010, 21 (03) : 157 - 160
  • [8] Neutron beam design for neutron radiography at the Musashi reactor
    Matsumoto, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 377 (01): : 48 - 51
  • [9] Design and simulation of time-of-flight neutron reflectometer
    LI Xinxi~* WANG Yan HUANG Chaoqiang CHEN Bo Institute of Nuclear Physics and Chemistry
    NuclearScienceandTechniques, 2010, 21 (03) : 157 - 160
  • [10] High contrast neutron radiography with optical devices in Kyoto University reactor
    Kawabata, Y
    Nakano, T
    Hino, M
    Sunohara, H
    Matsushima, U
    Takenaka, N
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 529 (1-3): : 238 - 242