Residual chlorine management in water distribution systems using network modelling techniques: case study in Seoul City

被引:4
|
作者
Ahn, JC [1 ]
Kim, YW [1 ]
Lee, KS [1 ]
Koo, JY [1 ]
机构
[1] Seoul Metropolitan Govt, Waterworks Res Inst, Seoul 143820, South Korea
关键词
chlorine decay; network modelling; neural networks; trihalomethanes;
D O I
10.2166/ws.2004.0134
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Twelve sampling locations in a network from a water treatment plant to consumers' taps were selected for measuring residual chlorine loss, THMs, TOC, etc. and 24 hour sampling in the locations was conducted on a bimonthly basis for one year. Chlorine bulk decay and THM formation tests were carried out by bottle tests under controlled temperatures for three locations: a water treatment plant, a large service reservoir, and a pumping station. Water quality modelling of chlorine loss in the distribution system was performed using data collected in the field study. This study contributed to the improvement of chlorine management in the distribution system by providing information for operators to maintain a minimum level of chlorine residual in a service reservoir.
引用
下载
收藏
页码:421 / 429
页数:9
相关论文
共 50 条
  • [1] Numeric Modelling of the Residual Chlorine Concentration Evolution in a Water Distribution Network
    Perju, Sorin
    Stanescu, Ioana
    REVISTA DE CHIMIE, 2015, 66 (06): : 886 - 890
  • [2] MODELING OF CHLORINE RESIDUAL IN THE WATER DISTRIBUTION NETWORK OF MACAO
    ZHANG, GR
    KIENE, L
    WABLE, O
    CHAN, US
    DUGUET, JP
    ENVIRONMENTAL TECHNOLOGY, 1992, 13 (10) : 937 - 946
  • [3] Research on distribution of residual chlorine in water supply network
    Yan, Lihua
    Liu, Liying
    Shenyang Jianzhu Daxue Xuebao (Ziran Kexue Ban)/Journal of Shenyang Jianzhu University (Natural Science), 2007, 23 (02): : 294 - 297
  • [5] Persistent Pockets of Low Chlorine Residual in New York City's Drinking Water Distribution System: A Case Study
    Stewart, Andrew
    Morales, Marshall
    Zaleski, Joseph
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 2019, 111 (10): : 52 - 57
  • [6] Persistent Pockets of Low Chlorine Residual in New York City's Drinking Water Distribution System: A Case Study
    Savane, Ousmane Sy
    Khan, Eakalak
    Freud, Salome
    Murphy, Amy
    Tesfargiogis, Kibre
    Murray, Virginia
    Journal - American Water Works Association, 2019, 111 (10): : 40 - 50
  • [7] Chlorine Concentration Modelling and Supervision in Water Distribution Systems
    Perez, Ramon
    Martinez-Torrents, Albert
    Martinez, Manuel
    Grau, Sergi
    Vinardell, Laura
    Tomas, Ricard
    Martinez-Llado, Xavier
    Jubany, Irene
    SENSORS, 2022, 22 (15)
  • [8] Optimization of water distribution of network systems using the Harris Hawks optimization algorithm (Case study: Homashahr city)
    Khalifeh, Saeid
    Akbarifard, Saeid
    Khalifeh, Vahid
    Zallaghi, Ebrahim
    METHODSX, 2020, 7
  • [9] Coliform occurrence and chlorine residual in small water distribution systems
    Goshko, M.A.
    Pipes, W.O.
    Christian, R.R.
    Journal / American Water Works Association, 1983, 75 (07): : 371 - 374
  • [10] Improving chlorine residual predictions in water distribution systems using recurrent neural networks
    Riyadh, Ammar
    Zayat, Abdullah
    Chaaban, Anas
    Peleato, Nicolas M.
    ENVIRONMENTAL SCIENCE-WATER RESEARCH & TECHNOLOGY, 2024, 10 (10) : 2533 - 2545