How to assess intra- and inter-observer agreement with quantitative PET using variance component analysis: a proposal for standardisation

被引:16
|
作者
Gerke, Oke [1 ,2 ]
Vilstrup, Mie Holm [1 ]
Segtnan, Eivind Antonsen [1 ]
Halekoh, Ulrich [3 ]
Hoilund-Carlsen, Poul Flemming [1 ,4 ]
机构
[1] Odense Univ Hosp, Dept Nucl Med, Sdr Blvd 29, DK-5000 Odense C, Denmark
[2] Univ Southern Denmark, Ctr Hlth Econ Res, Campusvej 55, DK-5230 Odense M, Denmark
[3] Univ Southern Denmark, Epidemiol Biostat & Biodemog, JB Winslows Vej 9b, DK-5000 Odense C, Denmark
[4] Univ Southern Denmark, Dept Clin Res, Winslowparken 19, DK-5000 Odense C, Denmark
来源
BMC MEDICAL IMAGING | 2016年 / 16卷
关键词
Bland-Altman limits of agreement; Intra-observer; Inter-observer; Intraobserver; Interobserver; Intra-rater; Inter-rater; Repeatability coefficient; Sample size; Standardised uptake value; FDG-PET/CT; BLOOD-FLOW; REPEATABILITY; F-18-FDG; EVENTS; REPRODUCIBILITY; RELIABILITY; GUIDELINES; TRACER;
D O I
10.1186/s12880-016-0159-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Quantitative measurement procedures need to be accurate and precise to justify their clinical use. Precision reflects deviation of groups of measurement from another, often expressed as proportions of agreement, standard errors of measurement, coefficients of variation, or the Bland-Altman plot. We suggest variance component analysis (VCA) to estimate the influence of errors due to single elements of a PET scan (scanner, time point, observer, etc.) to express the composite uncertainty of repeated measurements and obtain relevant repeatability coefficients (RCs) which have a unique relation to Bland-Altman plots. Here, we present this approach for assessment of intra- and inter-observer variation with PET/CT exemplified with data from two clinical studies. Methods: In study 1, 30 patients were scanned pre-operatively for the assessment of ovarian cancer, and their scans were assessed twice by the same observer to study intra-observer agreement. In study 2, 14 patients with glioma were scanned up to five times. Resulting 49 scans were assessed by three observers to examine inter-observer agreement. Outcome variables were SUVmax in study 1 and cerebral total hemispheric glycolysis (THG) in study 2. Results: In study 1, we found a RC of 2.46 equalling half the width of the Bland-Altman limits of agreement. In study 2, the RC for identical conditions (same scanner, patient, time point, and observer) was 2392; allowing for different scanners increased the RC to 2543. Inter-observer differences were negligible compared to differences owing to other factors; between observer 1 and 2: -10 (95 % CI: -352 to 332) and between observer 1 vs 3: 28 (95 % CI: -313 to 370). Conclusions: VCA is an appealing approach for weighing different sources of variation against each other, summarised as RCs. The involved linear mixed effects models require carefully considered sample sizes to account for the challenge of sufficiently accurately estimating variance components.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] How to assess intra- and inter-observer agreement with quantitative PET using variance component analysis: a proposal for standardisation
    Oke Gerke
    Mie Holm Vilstrup
    Eivind Antonsen Segtnan
    Ulrich Halekoh
    Poul Flemming Høilund-Carlsen
    BMC Medical Imaging, 16
  • [2] Midwives' visual interpretation of intrapartum cardiotocographs: intra- and inter-observer agreement
    Devane, D
    Lalor, J
    JOURNAL OF ADVANCED NURSING, 2005, 52 (02) : 133 - 141
  • [3] Intra- and inter-observer agreement of a protocol for clinical examination of dairy cows
    Thomsen, PT
    Baadsgaard, NP
    PREVENTIVE VETERINARY MEDICINE, 2006, 75 (1-2) : 133 - 139
  • [4] INTRA- AND INTER-OBSERVER AGREEMENT OF PROXIMAL HUMERAL FRACTURES CLASSIFICATIONS IN ADULTS
    Diaz, Luis Eduardo Plumacher
    Neto, Francisco Dada
    Lofrano, Lucas
    Garcia, Joao Vitor da Cruz
    Santana, Marcos Vinicius Felix
    Dobashi, Eiffel Tsuyoshi
    ACTA ORTOPEDICA BRASILEIRA, 2022, 30 (06):
  • [5] Ultrasound Assessment of Pubertal Breast Development: Intra- and Inter-observer Agreement
    Bruserud, Ingvild
    Mathieu, Roelants
    Oehme, Ninnie
    Eide, Geir Egil
    Bjerknes, Robert
    Rosendahl, Karen
    Juiliusson, Petur
    HORMONE RESEARCH IN PAEDIATRICS, 2018, 90 : 511 - 511
  • [6] Diaphragm Thickness Measurement in Computed Tomography: Intra- and Inter-Observer Agreement
    Ufuk, Furkan
    Cakmak, Pinar
    Sagtas, Ergin
    Herek, Duygu
    Arslan, Muhammet
    Yagci, Ahmet Baki
    ISTANBUL MEDICAL JOURNAL, 2019, 20 (02): : 101 - 106
  • [7] Intra- and Interobserver Agreement with Quantitative PET Measures: Deriving Repeatability Coefficients from Variance Component Analysis
    Gerke, O.
    Vilstrup, M. H.
    Segtnan, E. A.
    Halekoh, U.
    Hoilund-Carlsen, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S495 - S495
  • [8] Intra- and Inter-Observer Agreement on CT Scan Features of Chronic Pancreatitis (CP)
    Dasyam, A. K.
    Tirkes, T.
    Shah, Z. K.
    Tang, G.
    Vipperla, K.
    Greer, P. J.
    Topazian, M.
    Fogel, E. L.
    Conwell, D. L.
    Yadav, D.
    Takahashi, N.
    PANCREAS, 2017, 46 (10) : 1396 - 1396
  • [9] Intra- and inter-observer agreement for the histological diagnosis of Aberrant Crypt Foci (ACF)
    Jimeno, M.
    Cuatrecasas, M.
    Quintanilla, I.
    Lopez Ceron, M.
    Rodriguez de Miguel, C.
    Camps, J.
    Balaguer, F.
    Llach, J.
    Pellise, M.
    VIRCHOWS ARCHIV, 2014, 465 : S232 - S232
  • [10] Intra- and inter-observer agreement in histological assessment of canine soft tissue sarcoma
    Yap, F. W.
    Rasotto, R.
    Priestnall, S. L.
    Parsons, K. J.
    Stewart, J.
    VETERINARY AND COMPARATIVE ONCOLOGY, 2017, 15 (04) : 1553 - 1557