Type 1 diabetes is one of the most common endocrine problems in childhood and adolescence, and remains a serious chronic disorder with increased morbidity and mortality, and reduced quality of life. Technological innovations positively affect the management of type 1 diabetes. Closed-loop insulin delivery (artificial pancreas) is a recent medical innovation, aiming to reduce the risk of hypoglycemia while achieving tight control of glucose. Characterized by real-time glucose-responsive insulin administration, closed-loop systems combine glucose-sensing and insulin-delivery components. In the most viable and researched configuration, a disposable sensor measures interstitial glucose levels, which are fed into a control algorithm controlling delivery of a rapid-acting insulin analog into the subcutaneous tissue by an insulin pump. Research progress builds on an increasing use of insulin pumps and availability of glucose monitors. We review the current status of insulin delivery, focusing on clinical evaluations of closed-loop systems. Future goals are outlined, and benefits and limitations of closed-loop therapy contrasted. The clinical utility of these systems is constrained by inaccuracies in glucose sensing, inter- and intra-patient variability, and delays due to absorption of insulin from the subcutaneous tissue, all of which are being gradually addressed.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Closed-loop insulin delivery for treatment of type 1 diabetes
    Daniela Elleri
    David B Dunger
    Roman Hovorka
    BMC Medicine, 9
  • [2] Closed-Loop Insulin Delivery in Type 1 Diabetes
    Thabit, Hood
    Hovorka, Roman
    ENDOCRINOLOGY AND METABOLISM CLINICS OF NORTH AMERICA, 2012, 41 (01) : 105 - +
  • [3] Enlarging the loop: closed-loop insulin delivery for type 1 diabetes
    Galderisi, Alfonso
    Sherr, Jennifer L.
    LANCET, 2018, 392 (10155): : 1282 - 1284
  • [4] Closed-Loop Insulin Delivery Postpartum in Type 1 Diabetes
    Donovan, Lois E.
    Feig, Denice
    Lemieux, Patricia
    Murphy, Helen R.
    Bell, Rhonda C.
    Sigal, Ronald J.
    Ho, Josephine
    Yamamoto, Jennifer M.
    DIABETES, 2023, 72
  • [5] Overnight Closed-Loop Insulin Delivery in Patients with Type 1 Diabetes
    Wilinska, M. E.
    Allen, J. M.
    Elleri, D.
    Kumareswaran, K.
    Nodale, M.
    Evans, M. L.
    Dunger, D. B.
    Hovorka, R.
    5TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2012, 37 : 961 - 963
  • [6] Diabetes: Closed-loop insulin delivery
    Koch L.
    Nature Reviews Endocrinology, 2010, 6 (5) : 241 - 241
  • [7] Closed-Loop Insulin Delivery for Outpatients With Type 2 Diabetes
    Slomski, Anita
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2021, 326 (12): : 1139 - 1139
  • [9] A Randomized Trial of Closed-Loop Insulin Delivery Postpartum in Type 1 Diabetes
    Donovan, Lois E.
    Feig, Denice S.
    Lemieux, Patricia
    Murphy, Helen R.
    Bell, Rhonda C.
    Sigal, Ronald J.
    Ho, Josephine
    Virtanen, Heidi
    Crawford, Susan
    Yamamoto, Jennifer M.
    DIABETES CARE, 2023, 46 (12) : 2258 - 2266
  • [10] Advances in Closed-Loop Insulin Delivery Systems in Patients with Type 1 Diabetes
    Vikash Dadlani
    Jordan E. Pinsker
    Eyal Dassau
    Yogish C. Kudva
    Current Diabetes Reports, 2018, 18