Induced currents due to nearby lightning strike to a mobile radar system: an hybrid 3D/circuit analysis

被引:0
|
作者
Antonini, G. [1 ]
Cocchini, M. [1 ]
Dominicis, A. [2 ]
Italiani, M. [1 ]
Orlandi, A. [1 ]
机构
[1] Univ Aquila, Dept Elect Engn, UAq EMC Lab, Laquila, Italy
[2] Selex Sistemi Integrati, Rome, Italy
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The presence of a lightning protection system for mobile radar structure requires a detailed study of the electromagnetic effects due to a nearby lightning strike. Aim of this work is the evaluation of. the induced surface currents on the antenna unit, the currents flowing through the slip-ring (electro-mechanical part connecting the rotating part of the antenna with the fixed one) and the associated dissipated energy, the currents and voltages across the grounding conductors connecting the different units of the mobile radar system. A three dimensional full wave electromagnetic analysis is performed to characterize the induced currents on the antenna unit. This unit is the transformed in an equivalent voltage source. This circuit element is connected to the equivalent circuit model of the grounding cables and rods of the other units to compute the required electrical variables.
引用
收藏
页码:213 / +
页数:2
相关论文
共 50 条
  • [1] Characteristics of the Induced Currents in Horizontal Conductors Due to a Nearby Lightning Strike
    Goni, Md. Osman
    PROCEEDINGS OF ICECE 2008, VOLS 1 AND 2, 2008, : 32 - 37
  • [2] Preliminary studies on the characteristics of the induced currents in simple down conductors due to a nearby lightning strike
    Kumar, Udaya
    Hegde, Vishwanath
    Shivanand, Vinoda
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2006, 48 (04) : 805 - 816
  • [3] On the Influence of Neighboring Conducting Objects on the Induced Currents in Simple Down Conductors Due to Nearby Lightning Strike
    Shivanand, Vinoda
    Hegde, Vishwanath
    Kumar, Udaya
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2012, 40 (14) : 1533 - 1543
  • [4] On the Influence of Steel Geometry on the Induced Currents in Steel Reinforced Concrete Building due to a Nearby Lightning Strike to Ground
    Hegde, Vishwanath
    Shivanand, Vinoda
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2015, 57 (03) : 418 - 424
  • [5] Lightning Strike Location Identification Based on 3D Weather Radar Data
    Lu, Mingyue
    Zhang, Yadong
    Ma, Zaiyang
    Yu, Manzhu
    Chen, Min
    Zheng, Jianqin
    Wang, Menglong
    FRONTIERS IN ENVIRONMENTAL SCIENCE, 2021, 9
  • [6] Modeling of PV Module and DC/DC Converter Assembly for the Analysis of Induced Transient Response Due to Nearby Lightning Strike
    Formisano, Alessandro
    Hernandez, Jesus C.
    Petrarca, Carlo
    Sanchez-Sutil, Francisco
    ELECTRONICS, 2021, 10 (02) : 1 - 24
  • [7] Lightning current analysis for tall tower strike using 3D FEM
    Hossain, Md. Kamal
    Hossain, Md. Faruque
    JOURNAL OF ELECTROSTATICS, 2023, 125
  • [8] Induced Current Distribution in 3D Soil Model as Lightning Impulse Discharge Strike Earth Surface
    Fajingbesi, Fawwaz Eniola
    Midi, Nur Shahida
    Elsheikh, Elsheikh M. A.
    Yusoff, Siti Hajar
    Khan, Sheroz
    Azman, Amelia Wong
    2019 9TH INTERNATIONAL CONFERENCE ON POWER AND ENERGY SYSTEMS (ICPES), 2019,
  • [9] 3-D FDTD Analysis of Lightning-Induced Voltages in Distribution Lines Due to Inclined Lightning
    Natsui, Masashi
    Ametani, Akihiro
    Mahseredjian, Jean
    Sekioka, Shozo
    Yamamoto, Kazuo
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2021, 63 (01) : 189 - 197
  • [10] 3-D FDTD Analysis of Lightning-Induced Voltages in Distribution Lines Due to Inclined Lightning
    Natsui, Masashi
    Ametani, Akihiro
    Mahseredjian, Jean
    Sekioka, Shozo
    Yamamoto, Kazuo
    2021 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2021,