Shielding effect of the smoke plume by the ablation of excimer lasers

被引:1
|
作者
Szekrenyesi, Csaba [1 ]
Kiss, Huba [2 ]
Filkorn, Tamas [2 ]
Nagy, Zoltan Zsolt [1 ,2 ]
机构
[1] Semmelweis Univ, Fac Hlth Sci, Vas U 17, H-1088 Budapest, Hungary
[2] Semmelweis Univ, Dept Ophthalmol, Budapest, Hungary
来源
BMC OPHTHALMOLOGY | 2018年 / 18卷
关键词
Excimer lasers; PMMA; Laser ablation; Refractive surgery; PHOTOREFRACTIVE KERATECTOMY; REFRACTIVE SURGERY; PMMA; TEMPERATURE; DYNAMICS;
D O I
10.1186/s12886-018-0942-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BackgroundShielding and scattering effect of the smoke plume column ejected from the laser ablated material is a well-known phenomenon. Debris evacuation system of the excimer laser equipment removes these particles, but insufficient air flow can result in undesired refractive outcomes of the treatment. The aim of this study was to reveal the effect of the air flow speed on the actual ablation depth.MethodsSCWIND AMARIS 500E flying spot excimer laser was tested in this study. A 150m phototherapeutic keratectomy (PTK) profile with 8mm diameter was applied to the surface of polymethyl methacrylate (PMMA) plates. The velocity of the air flow was changed with adjustable air aspiration system. Ablation depth was measured with highly-precise contact micrometer.ResultsThe prediction model was statistically significant, F(1,8)=552.85, p<0.001, and accounted for approximately 98.7% of variance of ablation (R-2=0.987, R-adj(2)=0.986). Lower air flow speed resulted in a weaker ablation capability of the excimer laser.ConclusionAir flow generated by the aspiration equipment is a key factor for the predictable outcomes of refractive treatment. Therefore, manufacturer inbuilt debris removal system should be regularly checked and maintained to ensure proper clinical and predictable refractive results.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Shielding effect of the smoke plume by the ablation of excimer lasers
    Csaba Szekrényesi
    Huba Kiss
    Tamás Filkorn
    Zoltán Zsolt Nagy
    BMC Ophthalmology, 18
  • [2] Effect of plume dynamics on the uniformity of excimer laser ablation for microfabrication
    Harvey, EC
    Hayes, JP
    DEVICE AND PROCESS TECHNOLOGIES FOR MEMS, MICROELECTRONICS, AND PHOTONICS III, 2004, 5276 : 92 - 99
  • [3] POLYMER ABLATION WITH EXCIMER LASERS
    YABE, A
    NIINO, H
    MOLECULAR CRYSTALS AND LIQUID CRYSTALS, 1993, 224 : 111 - 121
  • [4] ABLATION OF POLYMERS WITH EXCIMER LASERS
    ELLIOTT, DJ
    PHOTONICS SPECTRA, 1988, 22 (02) : 93 - &
  • [5] Plume dynamics and shielding by the ablation plume during Er:YAG laser ablation
    Nahen, K
    Vogel, A
    JOURNAL OF BIOMEDICAL OPTICS, 2002, 7 (02) : 165 - 178
  • [6] ABLATION PROCESSES WITH UV EXCIMER LASERS
    DREYFUS, RW
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1992, 203 : 107 - ANYL
  • [7] Shielding by the ablation plume during Er:YAG laser ablation
    Nahen, K
    Vogel, A
    LASER-TISSUE INTERACTION XII: PHOTOCHEMICAL, PHOTOTHERMAL, AND PHOTOMECHANICAL, 2001, 4257 : 282 - 297
  • [8] Ablation plume particle dynamics during excimer laser ablation of polyimide
    Sandia Natl Lab, Livermore, United States
    J Appl Phys, 6 (2759-2766):
  • [9] Modeling of plume dynamics with shielding in laser ablation of carbon
    Pathak, Kedar
    Povitsky, Alex
    APPLIED SURFACE SCIENCE, 2007, 253 (15) : 6359 - 6365
  • [10] DYNAMICS OF ABLATION PLUME PARTICLES GENERATED DURING EXCIMER-LASER CORNEAL ABLATION
    HAHN, DW
    EDIGER, MN
    PETTIT, GH
    LASERS IN SURGERY AND MEDICINE, 1995, 16 (04) : 384 - 389