Photoelastic analysis of all-on-four concept using different implants angulations for maxilla

被引:8
|
作者
Vemba Cidade, Castelo Pedro [1 ]
Pimentel, Marcele Jardim [2 ]
do Amaral, Regiane Cristina [3 ]
de Arruda Nobilo, Mauro Antonio [2 ]
de Albergaria Barbosa, Jose Ricardo [1 ]
机构
[1] Univ Campinas UNICAMP, Piracicaba Dent Sch, Dept Surg, Piracicaba, SP, Brazil
[2] Univ Campinas UNICAMP, Piracicaba Dent Sch, Dept Prosthodont & Periodontol, Piracicaba, SP, Brazil
[3] Univ Campinas UNICAMP, Piracicaba Dent Sch, Dept Community Med, Piracicaba, SP, Brazil
来源
BRAZILIAN ORAL RESEARCH | 2014年 / 28卷 / 06期
关键词
Dental Implants; Maxilla; Bone Resorption; STRESS-DISTRIBUTION; EDENTULOUS MAXILLA; CANTILEVER LENGTH; PROSTHESES; FIT;
D O I
10.1590/1807-3107BOR-2014.vol28.0051
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Conventional tilted implants are used in oral rehabilitation for heavily absorbed maxilla to avoid bone grafts; however, few research studies evaluate the biomechanical behavior when different angulations of the implants are used. The aim of this study was evaluate, trough photoelastic method, two different angulations and length of the cantilever in fixed implant-supported maxillary complete dentures. Two groups were evaluated: G15 (distal tilted implants 15) and G35 (distal tilted implants 35) n = 6. For each model, 2 distal tilted implants (3.5 x 15 mm long cylindrical cone) and 2 parallel tilted implants in the anterior region (3.5 x 10 mm) were installed. Photoelastic models were submitted to three vertical load tests: in the end of cantilever, in the last pillar and in the all pillars at the same time. We obtained the shear stress by Fringes software and found values for total, cervical and apical stress. The quantitative analysis was performed using the Student tests and Mann-Whitney test; p >= 0.05. There is no difference between G15 and G35 for total stress regardless of load type. Analyzing the apical region, G35 reduced strain values considering the distal loads (in the cantilever p = 0.03 and in the last pillar p = 0.02), without increasing the stress level in the cervical region. Considering the load in all pillars, G35 showed higher stress concentration in the cervical region (p = 0.04). For distal loads, G15 showed increase of tension in the apical region, while for load in all pillars, G35 inclination increases stress values in the cervical region.
引用
收藏
页码:478 / 484
页数:7
相关论文
共 50 条
  • [1] Comparison of stress distribution around all-on-four implants of different angulations and zygoma implants: a 7-model finite element analysis
    Tezerisener, Hueseyin Alican
    Ozalp, Oznur
    Altay, Mehmet Ali
    Sindel, Alper
    [J]. BMC ORAL HEALTH, 2024, 24 (01)
  • [2] Comparison of stress distribution around all-on-four implants of different angulations and zygoma implants: a 7-model finite element analysis
    Hüseyin Alican Tezerişener
    Öznur Özalp
    Mehmet Ali Altay
    Alper Sindel
    [J]. BMC Oral Health, 24
  • [3] Biomechanical analysis of immediately loaded implants according to the "All-on-Four" concept
    Horita, Satoshi
    Sugiura, Tsutomu
    Yamamoto, Kazuhiko
    Murakami, Kazuhiro
    Imai, Yuichiro
    Kirita, Tadaaki
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2017, 61 (02) : 123 - 132
  • [4] "All-on-four" concept and immediate loading for simultaneous rehabilitation of the atrophic maxilla and mandible with conventional and zygomatic implants
    Ferreira, Edilson Jose
    Kuabara, Marcos Rikio
    Gulinelli, Jessica Lemos
    [J]. BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2010, 48 (03): : 218 - 220
  • [5] Finite Element Stress Analysis of Applied Forces to Implants and Supporting Tissues Using the "All-on-Four" Concept with Different Occlusal Schemes
    Turker, Nurullah
    Buyukkaplan, Ulviye S.
    Sadowsky, Steven J.
    Ozarslan, Mehmet M.
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (02): : 185 - 194
  • [6] A New Approach to the All-on-Four Treatment Concept Using Narrow Platform NobelActive Implants
    Babbush, Charles A.
    Kanawati, Ali
    Brokloff, John
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2013, 39 (03) : 314 - 325
  • [7] Maxillary "All-On-Four'' treatment using zygomatic implants. A mechanical analysis
    de Moraes, P. H.
    Olate, S.
    de Arruda Nobilo, M.
    Asprino, L.
    de Moraes, M.
    de Albergaria Barbosa, J.
    [J]. REVUE DE STOMATOLOGIE DE CHIRURGIE MAXILLO-FACIALE ET DE CHIRURGIE ORALE, 2016, 117 (02) : 67 - 71
  • [8] The All-on-Four Immediate Function Treatment Concept With NobelActive Implants: A Retrospective Study
    Babbush, Charles A.
    Kutsko, Gary T.
    Brokloff, John
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2011, 37 (04) : 431 - 445
  • [9] Stress Patterns Around Distal Angled Implants in the All-on-Four Concept Configuration
    Begg, Tasneem
    Geerts, Greta A. V. M.
    Gryzagoridis, Jasson
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2009, 24 (04) : 663 - 671
  • [10] Assessment of Stress Distribution Around Dental Implants Based on the All-on-Four Treatment Concept using Finite Element Analysis
    Bhoi, Shreedevi
    Baghel, Arjun Singh
    Deepa, E.
    Naveen, Reddy R.
    Nadakkavukaran, Davis
    Borra, Anusha
    Rao, Kumuda
    [J]. JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2023, 15 : S907 - S909