The external unit of small telemetry system for animals uses inductive link to transmit both data and power to a small implant. In this work, firstly, we have presented a wideband frequency shift keying (FSK) transmitter, which is a class E power amplifier (PA) switches between two load networks that make the PA tuned correctly at tow input clock frequencies. Carrier frequencies used for data modulation are 5MHz/10MHz, the data rate of the proposed link is 2.5 Mbps. On the other hand, the analog circuits of the internal unit are designed in this paper. Internal unit has a demodulator circuit to derive directly a frequency clock from the FSK carrier and to sample the binary data stream. It also has a low power generator circuit to generate the supply voltage to the other blocks. The low power generator is composed of a high efficiency, low power rectifier, and a low power voltage regulator. To minimize the quiescent current of the regulator, we propose a control section which is a two-stage error amplifier to control the gate voltage of the PMOS transistors used in the differential pair of the voltage regulator and thus stabilize the direct current (DC) level at its output signal (V-reg). The output voltage of the proposed generator circuit is regulated at 1V, the quiescent current simulated is about 9.9 mu A and the line regulation performance is only 8mV/V. All circuits proposed in this paper were designed and simulated using Cadence in 180 nm CMOS technology.
引用
收藏
页码:244 / 253
页数:10
相关论文
共 50 条
  • [1] TELEMETRY SYSTEM FOR RECORDING MASTICATION IN SMALL ANIMALS
    RUGH, JD
    [J]. MEDICAL & BIOLOGICAL ENGINEERING, 1970, 8 (05): : 497 - &
  • [2] A novel telemetry system for recording EEG in small animals
    Chang, Pishan
    Hashemi, Kevan S.
    Walker, Matthew C.
    [J]. JOURNAL OF NEUROSCIENCE METHODS, 2011, 201 (01) : 106 - 115
  • [3] AN INEXPENSIVE TELEMETRY SYSTEM FOR DETERMINATION OF HEART RATE OF SMALL ANIMALS
    SCOTT, NR
    JOHNSON, AT
    [J]. AGRICULTURAL ENGINEERING, 1969, 50 (10): : 608 - &
  • [4] A SIMPLIFIED TELEMETRY SYSTEM FOR MONITORING BODY-TEMPERATURE IN SMALL ANIMALS
    VAROSI, SM
    BRIGMON, RL
    BESCH, EL
    [J]. LABORATORY ANIMAL SCIENCE, 1990, 40 (03): : 299 - 302
  • [6] A lightweight telemetry system for recording neuronal activity in freely behaving small animals
    Schregardus, Diederik S.
    Pieneman, Anton W.
    Ter Maat, Andries
    Jansen, Rene F.
    Brouwer, Tinco J. F.
    Gahr, Manfred L.
    [J]. JOURNAL OF NEUROSCIENCE METHODS, 2006, 155 (01) : 62 - 71
  • [7] TOWARDS AN IMPLANTABLE TELEMETRY SYSTEM FOR PHOTOPLETHYSMOGRAPHY BASED VITAL SIGNS MONITORING IN SMALL ANIMALS
    Wang, Qing
    Brun, Noe
    Huang, Qiuting
    Schonle, Philipp
    [J]. JOURNAL OF HYPERTENSION, 2018, 36 : E12 - E12
  • [8] Towards an Implantable Telemetry System for SpO2 and PWV Measurement in Small Animals
    Schonle, Philipp
    Wang, Qing
    Brun, Noe
    Boser, Jonathan
    Meier, Pascale
    Huang, Qiuting
    [J]. 2017 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2017,
  • [9] A SYSTEM FOR BIOLOGICAL PRESSURE TELEMETRY IN CONSCIOUS ANIMALS
    NONAKA, K
    UENO, A
    [J]. FOLIA PHARMACOLOGICA JAPONICA, 1980, 76 (07) : 549 - 552
  • [10] 6-CHANNEL TELEMETRY SYSTEM FOR ANIMALS
    MULLER, B
    GLATT, AF
    [J]. EXPERIENTIA, 1977, 33 (06): : 782 - 783