Preparation of phenyl-silica hybrid monolithic column with "one-pot" process for capillary liquid chromatography

被引:33
|
作者
Zhang, Zhenbin [1 ,2 ]
Lin, Hui [1 ,2 ]
Ou, Junjie [1 ]
Qin, Hongqiang [1 ,2 ]
Wu, Ren'an [1 ]
Dong, Jing [1 ]
Zou, Hanfa [1 ]
机构
[1] Chinese Acad Sci, Dalian Inst Chem Phys, CAS Key Lab Separat Sci Analyt Chem, Natl Chromatog R&A Ctr, Dalian 116023, Peoples R China
[2] Chinese Acad Sci, Grad Sch, Beijing 100049, Peoples R China
关键词
One-pot; Sol-gel; Phenyl-silica hybrid monolith; Capillary liquid chromatography; IONIZATION MASS-SPECTROMETRY; STATIONARY PHASES; SEPARATION; EFFICIENCY; SINGLE;
D O I
10.1016/j.chroma.2011.07.048
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A phenyl-silica hybrid monolithic column for capillary liquid chromatography (cLC) was prepared through "one-pot" process by con-currently using benzyl methacrylate and alkoxysilanes. The effects of the molar ratio of tetramethoxysilane/vinyltrimethoxysilane (TMOS/VTMS), polycondensation temperature, content of supramolecule template (cetyltrimethylammonium bromide, CTAB), ratio of N,N'-dimethylformamide/methanol (v/v), the volume of benzyl methacrylate on the morphologies of the prepared phenyl-silica hybrid monolithic columns were investigated in detail. The permeability of the hybrid monolithic column was calculated as 3.23 x 10(-13) m(2), and the minimum plate height was determined as 8.38 mu m which corresponding to 119,000 theoretical plates per meter. Separation of various neutral, polar and basic analytes as well as small peptides on the hybrid monolithic column was achieved by cLC and showed high efficiency and satisfactory reproducibility. Moreover, the prepared hybrid monolithic column was also applied for the analysis of Cryptic digests of bovine serum albumin (BSA), ovalbumin, a-casein, cytochrome C and myoglobin by cLC tandem mass spectrometry (cLC-MS/MS), and the results showed that the separation performance was close to that of the octadecylsilane (C18) packed capillary column which demonstrating its potential in proteome analysis. Moreover, since the prepolymerization system was mainly consisted of organic solvents (methanol and N,N'-dimethylformamide). various hydrophobic monomers could be potentially used to prepare organic-silica hybrid monolithic columns through "one-pot" approach. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:263 / 269
页数:7
相关论文
共 50 条
  • [1] Preparation of a butyl–silica hybrid monolithic column with a “one-pot” process for bioseparation by capillary liquid chromatography
    Zhenbin Zhang
    Fangjun Wang
    Junjie Ou
    Hui Lin
    Jing Dong
    Hanfa Zou
    Analytical and Bioanalytical Chemistry, 2013, 405 : 2265 - 2271
  • [2] Preparation of a butyl-silica hybrid monolithic column with a "one-pot" process for bioseparation by capillary liquid chromatography
    Zhang, Zhenbin
    Wang, Fangjun
    Ou, Junjie
    Lin, Hui
    Dong, Jing
    Zou, Hanfa
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (07) : 2265 - 2271
  • [3] Preparation of phenylboronic acid-silica hybrid monolithic column with one-pot approach for capillary liquid chromatography of biomolecules
    Lin, Zian
    Huang, Hui
    Li, Shihua
    Wang, Juan
    Tan, Xiaoqing
    Zhang, Lan
    Chen, Guonan
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1271 : 115 - 123
  • [4] Preparation of Perphenylcarbamoylated β-Cyclodextrin-silica Hybrid Monolithic Column with "One-Pot" Approach for Enantioseparation by Capillary Liquid Chromatography
    Zhang, Zhenbin
    Wu, Minghuo
    Wu, Ren'an
    Done, Jing
    Ou, Junjie
    Zou, Hanfa
    ANALYTICAL CHEMISTRY, 2011, 83 (09) : 3616 - 3622
  • [5] Preparation of C18-silica hybrid monolithic capillary column by "one-pot" process and its application
    Zhang Zhenbin
    Ou Junjie
    Dong Jing
    Wang Fangjun
    Wu Minghuo
    Lin Hui
    Zou Hanfa
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2011, 29 (09) : 830 - 836
  • [6] "One-pot" preparation of basic amino acid-silica hybrid monolithic column for capillary electrochromatography
    Xu, Hongrui
    Xu, Zhendong
    Yang, Limin
    Wang, Qiuquan
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (16-17) : 2314 - 2322
  • [7] Hydrothermal preparation of hybrid carbon/silica monolithic capillary column for liquid chromatography
    Yang, Peiling
    Wang, Wentao
    Xiao, Xing
    Jia, Li
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (15) : 1911 - 1918
  • [8] Facile Preparation of Zwitterionic Organic-Silica Hybrid Monolithic Capillary Column with an Improved "One-Pot" Approach for Hydrophilic-Interaction Liquid Chromatography (HILIC)
    Lin, Hui
    Ou, Junjie
    Zhang, Zhenbin
    Dong, Jing
    Wu, Minghuo
    Zou, Hanfa
    ANALYTICAL CHEMISTRY, 2012, 84 (06) : 2721 - 2728
  • [9] Preparation and evaluation of monolithic silica column for capillary liquid chromatography
    Lu Yan
    Guo Jianyu
    Zhang Xiangmin
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 (10) : 1463 - 1466
  • [10] Facile preparation of organic-inorganic hybrid polymeric ionic liquid monolithic column with a one-pot process for protein separation in capillary electrochromatography
    Cuicui Liu
    Qiliang Deng
    Guozhen Fang
    Xue Feng
    Hailong Qian
    Shuo Wang
    Analytical and Bioanalytical Chemistry, 2014, 406 : 7175 - 7183