Selection of orthogonal reversed-phase HPLC systems by univariate and auto-associative multivariate regression trees

被引:12
|
作者
Put, R
Van Gyseghem, E
Coomans, D
Vander Heyden, Y
机构
[1] Vrije Univ Brussels, Inst Pharmaceut, Dept Pharmaceut & Biomed Anal, B-1090 Brussels, Belgium
[2] James Cook Univ N Queensland, Stat Intelligent Data Anal Grp, Townsville, Qld 4814, Australia
关键词
orthogonal chromatographic systems; CART; univariate regression trees; multivariate regression trees; method development; unsupervised;
D O I
10.1016/j.chroma.2005.03.138
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In order to select chromatographic starting conditions to be optimized during further method development of the separation of a given mixture, so-called generic orthogonal chromatographic systems could be explored in parallel. In this paper the use of univariate and multivariate regression trees (MRT) was studied to define the most orthogonal subset from a given set of chromatographic systems. Two data sets were considered, which contain the retention data of 68 structurally diversive drugs on sets of 32 and 38 chromatographic systems, respectively. For both the univariate and multivariate approaches no other data but the measured retention factors are needed to build the decision trees. Since multivariate regression trees are used in an unsupervised way, they are called auto-associative multivariate regression trees (AAMRT). For all decision trees used, a variable importance list of the predictor variables can be derived. It was concluded that based on these ranked lists, both for univariate and multivariate regression trees, a selection of the most orthogonal systems from a given set of systems can be obtained in a user-friendly and fast way. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:187 / 198
页数:12
相关论文
共 31 条
  • [1] Auto-associative multivariate regression trees for cluster analysis
    Smyth, C
    Coomans, D
    Everingham, Y
    Hancock, T
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2006, 80 (01) : 120 - 129
  • [2] Column Selection for Reversed-Phase HPLC
    不详
    LC GC NORTH AMERICA, 2013, 31 (03) : 262 - 262
  • [3] Column Selection for Reversed-Phase HPLC
    不详
    LC GC EUROPE, 2013, 26 (03) : 172 - 172
  • [4] Dissimilar or orthogonal reversed-phase chromatographic systems: A comparison of selection techniques
    Dumarey, M.
    Put, R.
    Van Gyseghem, E.
    Heyden, Y. Vander
    ANALYTICA CHIMICA ACTA, 2008, 609 (02) : 223 - 234
  • [5] Modifier influence on selectivity of reversed-phase HPLC systems
    Dzido, TH
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2000, 23 (18) : 2773 - 2788
  • [6] CHROMATOGRAPHIC BEHAVIOR OF FLAVONOID COMPOUNDS IN REVERSED-PHASE HPLC SYSTEMS
    DONDI, F
    BLO, G
    KAHIE, YD
    LODI, G
    PIETROGRANDE, C
    RESCHIGLIAN, P
    CHROMATOGRAPHIA, 1988, 25 (05) : 423 - 429
  • [7] Fault Detection Method based on Auto-associative Kernel Regression and Interval Type-2 Fuzzy Logic System for Multivariate Process
    Jung, Seunghwan
    Kim, Minseok
    Kim, Joungguen
    Kim, Sungshin
    IEEE CIS INTERNATIONAL CONFERENCE ON FUZZY SYSTEMS 2021 (FUZZ-IEEE), 2021,
  • [8] ON THE MECHANISM OF SOLUTE RETENTION IN REVERSED-PHASE HPLC SYSTEMS WITH METHANOL-WATER ELUENT
    KOWALSKA, T
    KUS, P
    CHROMATOGRAPHIA, 1990, 29 (11-12) : 583 - 586
  • [9] Orthogonal Reversed-Phase C18 and Pentafluorophenyl HPLC Separation for Phytochemical Profiling of Serrulatanes in Eremophila denticulata
    Zhao, Yong
    Li, Tuo
    Kjaerulff, Louise
    Venter, Henrietta
    Coriani, Sonia
    Moller, Birger Lindberg
    Semple, Susan
    Staerk, Dan
    JOURNAL OF NATURAL PRODUCTS, 2023, 86 (12): : 2638 - 2650
  • [10] ADAPTATION OF REVERSED-PHASE HPLC SYSTEMS WITH HIGH WATER-CONTENT TO THIN-LAYER CHROMATOGRAPHY - BIOAUTOGRAPHY OF REVERSED-PHASE THIN-LAYER CHROMATOGRAMS
    ARX, EV
    FAUPEL, M
    JOURNAL OF CHROMATOGRAPHY, 1978, 154 (01): : 68 - 72