Experimental Analysis of In Situ Fenestration of Endovascular Stent-Grafts: Comparison between Needle and Laser Puncture

被引:7
|
作者
Zeng, Qinglong [1 ]
Zhou, Xiang [1 ]
He, Yunjun [1 ]
Wang, Xiaohui [1 ]
Shang, Tao [1 ]
He, Yangyan [1 ]
Wu, Ziheng [1 ]
Zhang, Hongkun [1 ]
Li, Donglin [1 ]
机构
[1] Zhejiang Univ, Sch Med, Dept Vasc Surg, Affiliated Hosp 1, 79 Qingchun Rd, Hangzhou 310003, Peoples R China
关键词
LEFT SUBCLAVIAN ARTERY; DURABILITY; OUTCOMES; REPAIR;
D O I
10.1016/j.avsg.2021.05.021
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: To evaluate the quality of in vitro fenestrations during in situ fenestration (ISF) and investigate the differences between needle and laser puncture in current stent-grafts. Methods: An in vitro study evaluated the damage created by needle ISF on stent-graft fabrics versus laser ISF. Fenestrations were made in 5 different commercially available stent-grafts, including polyester stent-grafts (Relay, Valiant and Hercules) and expanded polytetrafluoroethylene (ePTFE) stent-grafts (TAG and Ankura). Each stent-graft received fenestration by needle and laser separately, followed by gradual dilation (4 mm, 6 mm, 8 mm, and 10 mm sequentially) of noncompliant balloons. Quantitative and qualitative evaluations including fenestration diameter, area, shape and margins were conducted using light microscopy and scanning electron microscope. Results: The primary fenestrations created by needle were slit-like with visible cut-off fibers in polyester stent-grafts and were almost circular with clear margins in ePTFE stent-grafts; those created by laser were squared or elliptical with ragged edges and burned fibers in all the stentgrafts. Fabric debris and toxic particles due to burning of the material were generated during laser-assisted fenestration. The Primary holes in polyester stent-grafts (Relay, Valiant and Hercules) by needle showed smaller area (0.05 mm(2) vs. 0.22 mm(2), 0.52 mm(2) vs. 0.70 mm(2) and 0.28 mm(2) vs. 0.46 mm(2); P < 0.01) and worse shape (0.93 vs. 2.46, 1.17 vs. 2.33 and 0.93 vs. 2.47; P < 0.01) than those by laser, while larger area (0.67 vs.0.43, 0.59 vs.0.45; P < 0.05), better shape (3.93 vs. 2.53, 3.90 vs. 2.93; P < 0.05) and better margin (3.83 vs. 2.47, 3.83 vs. 2.53; P < 0.05) in ePTFE stent-grafts (TAG and Ankrura). After gradual balloon dilation, the final holes showed no evident difference in maximal length, fenestration area, scores of shape and margin between the 2 ways of fenestration (P > 0.05). Ankura stent-graft showed the largest holes with best quality than the others. Conclusions: The primary fenestrations were different between needle and laser puncture, laser induced fabric debris and toxic particles release should be cautiously considered. The final fenestrations were similar after gradual balloon dilation.
引用
收藏
页码:280 / 287
页数:8
相关论文
共 50 条
  • [1] In Vitro Fenestration of Aortic Stent-Grafts: Implications of Puncture Methods for in Situ Fenestration Durability
    Riga, Celia V.
    Bicknell, Colin D.
    Basra, Melvinder
    Hamady, Mohamad
    Cheshire, Nicholas J. W.
    JOURNAL OF ENDOVASCULAR THERAPY, 2013, 20 (04) : 536 - 543
  • [2] Experimental Analysis of the Quality of Needle-Assisted Fenestration in Aortic Stent-Grafts and the Differences Between Gradual and Rapid Balloon Dilation
    Li, Dong-lin
    Zeng, Qing-long
    Xiang, Yi-lang
    Qiu, Chen-yang
    Li, Zhen-jiang
    He, Yang-yan
    Zhu, Qian-qian
    Wu, Zi-heng
    Wang, Xun
    Zhang, Hong-kun
    JOURNAL OF ENDOVASCULAR THERAPY, 2021, 28 (01) : 44 - 52
  • [3] Optimal In Situ Fenestration Technique With Laser Perforation and Balloon Dilation for Aortic Stent-Grafts
    Lin, Jing
    Rodriguez, Limael E.
    Nutley, Mark
    Jun, Lu
    Mao, Ying
    Parikh, Niraj
    Alie-Cusson, Fanny
    Zhang, Ze
    Wang, Lu
    Panneton, Jean M.
    Guidoin, Robert
    JOURNAL OF ENDOVASCULAR THERAPY, 2021, 28 (02) : 300 - 308
  • [4] In Situ Needle Fenestration during Thoracic Endovascular Aneurysm Repair: Successful Fenestration of Two Overlapping Thoracic Stent Grafts
    Sfyroeras, Georgios S.
    Georgiadi, Eleni
    Papavasileiou, Georgia
    Spiliopoulos, Stavros
    Kakisis, John D.
    VASCULAR AND ENDOVASCULAR SURGERY, 2024, 58 (08) : 866 - 870
  • [5] Graft Durability and Fatigue after In Situ Fenestration of Endovascular Stent Grafts Using Radiofrequency Puncture and Balloon Dilatation
    Eadie, L. A.
    Soulez, G.
    King, M. W.
    Tse, L. W.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2014, 47 (05) : 501 - 508
  • [6] In Vitro Laser Fenestration of Aortic Stent-Grafts: A Qualitative Analysis Under Scanning Electron Microscope
    Lin, Jing
    Udgiri, Naval
    Guidoin, Robert
    Panneton, Jean
    Guan, Xiaoning
    Guillemette, Maxime
    Wang, Lu
    Du, Jia
    Zhu, Dajie
    Nutley, Mark
    Zhang, Ze
    ARTIFICIAL ORGANS, 2016, 40 (11) : E241 - E252
  • [7] Clinical outcomes and material properties of in situ fenestration of endovascular stent grafts
    Crawford, Sean A.
    Sanford, Ryan M.
    Forbes, Thomas L.
    Amon, Cristina H.
    Doyle, Matthew G.
    JOURNAL OF VASCULAR SURGERY, 2016, 64 (01) : 244 - 250
  • [8] Motion analysis of endovascular Stent-Grafts by MDL based registration
    Langs, Georg
    Paragios, Nikos
    Donner, Rene
    Desgranges, Pascal
    Rahmouni, Alain
    Kobeiter, Hicham
    2007 IEEE 11TH INTERNATIONAL CONFERENCE ON COMPUTER VISION, VOLS 1-6, 2007, : 2503 - +
  • [9] Design of a sensorized guiding catheter for in situ laser fenestration of endovascular stent
    Piazza, Roberta
    Condino, Sara
    Alberti, Aldo
    Berchiolli, Raffaella Nice
    Coppi, Gioachino
    Gesi, Marco
    Ferrari, Vincenzo
    Ferrari, Mauro
    COMPUTER ASSISTED SURGERY, 2017, 22 (01) : 27 - 38
  • [10] Laser fenestration of aortic arch stent grafts for endovascular treatment of retrograde type A dissection
    Qin, Jinbao
    Wu, Xiaoyu
    Li, Weimin
    Ye, Kaichuang
    Yin, Minyi
    Liu, Guang
    Cui, Chaoyi
    Zhao, Zhen
    Liu, Xiaobing
    Lu, Xinwu
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2021, 328 : 69 - 74