A Pattern Extraction Based Background Calibration Technique for SAR ADCs

被引:3
|
作者
Ding, Xiang [1 ]
Zhang, Liang [2 ]
Liu, Wenfeng [2 ]
Yi, Dongbai [2 ]
Ma, Yingjiang [2 ]
Hofmann, Klaus [1 ]
机构
[1] Tech Univ Darmstadt, Integrated Elect Syst Lab, D-64283 Darmstadt, Germany
[2] Gree Elect Appliances Inc, Commun Technol Res Inst, Zhuhai 519015, Peoples R China
关键词
Calibration; Convergence; Engines; Capacitors; Mathematical model; Training; Limiting; Digital background calibration; successive approximation register (SAR) analog-to-digital converters (ADCs); least mean square (LMS);
D O I
10.1109/TCSII.2021.3083805
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This brief presents a pattern extraction based digital background calibration for Successive Approximation Register (SAR) Analog-to-Digital Converters (ADCs). We demonstrate that major factors limiting the convergence rate of the conventional calibration schemes can be addressed by performing pattern extraction and using the extracted patterns to train the calibration engine. Benefiting from the proposed technique, the convergence speed of the calibration can be improved without sacrificing the stability and accuracy of the calibration loop. A lightweight pattern extraction scheme is also introduced to reduce the hardware cost and power consumption.
引用
收藏
页码:10 / 14
页数:5
相关论文
共 50 条
  • [1] A code-pattern-driven digital background calibration technique for SAR ADCs
    Haowei Lu
    Zhenghao Lu
    Xinjie Wu
    Yuyan Liu
    Xiaopeng Yu
    Analog Integrated Circuits and Signal Processing, 2022, 113 : 1 - 8
  • [2] A code-pattern-driven digital background calibration technique for SAR ADCs
    Lu, Haowei
    Lu, Zhenghao
    Wu, Xinjie
    Liu, Yuyan
    Yu, Xiaopeng
    ANALOG INTEGRATED CIRCUITS AND SIGNAL PROCESSING, 2022, 113 (01) : 1 - 8
  • [3] Digital background calibration technique for pipelined SAR ADCs with detect-and-switching algorithm
    Zhang, Lizhen
    Han, Shanshan
    Huang, Linlin
    Wu, Jianhui
    ELECTRONICS LETTERS, 2020, 56 (11) : 533 - 535
  • [4] Split-Delta Background Calibration for SAR ADCs
    Pena-Ramos, Juan-Carlos
    Verhelst, Marian
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II-EXPRESS BRIEFS, 2017, 64 (02) : 221 - 225
  • [5] A New Technique for Background Calibration of Pipelined ADCs
    Mohammadi, Meysam
    Alipour, Amir
    Aghdam, Esmaeil N.
    Sadeghipour, Khosrov D.
    2013 21ST IRANIAN CONFERENCE ON ELECTRICAL ENGINEERING (ICEE), 2013,
  • [6] Background calibration based on signal-dependent dithering for pipelined SAR ADCs exploiting noise quantiser technique
    Zhang, Lizhen
    Wang, Peng
    Huang, Linlin
    Wu, Jianhui
    ELECTRONICS LETTERS, 2020, 56 (05) : 227 - 229
  • [7] Equalization-Based Digital Background Calibration Technique for Pipelined ADCs
    Zeinali, Behzad
    Moosazadeh, Tohid
    Yavari, Mohammad
    Rodriguez-Vazquez, Angel
    IEEE TRANSACTIONS ON VERY LARGE SCALE INTEGRATION (VLSI) SYSTEMS, 2014, 22 (02) : 322 - 333
  • [8] A statistics-based digital background calibration technique for pipelined ADCs
    Mafi, Hamidreza
    Mohammadi, Reza
    Shamsi, Hossein
    INTEGRATION-THE VLSI JOURNAL, 2015, 51 : 149 - 157
  • [9] A Split-Based Digital Background Calibration Technique in Pipelined ADCs
    Hung, Li-Han
    Lee, Tai-Cheng
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II-EXPRESS BRIEFS, 2009, 56 (11) : 855 - 859
  • [10] Perturbation-Based Digital Background Calibration Technique for Pipelined ADCs
    Chung, Yung-Hui
    2014 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2014, : 1316 - 1319