Method improving low Signal-to-noise ratio of velocity test signals for Laser-induced shock waves

被引:9
|
作者
Haonian, Wu [1 ]
Li, Yan [1 ]
Yuyuan, Tang [2 ]
Xiangfan, Nie [1 ]
机构
[1] Chongqing Jiaotong Univ, Coll Traff & Transportat, Chongqing 400074, Peoples R China
[2] Air Force Engn Univ, Sci & Technol Plasma Dynam Lab, Xian, Peoples R China
来源
基金
中国国家自然科学基金; 美国国家科学基金会;
关键词
Laser-induced shock wave; Photon Doppler velocimetry (PDV); Signal processing methods; continuous wavelet transform (CWT); Shannon wavelet entropy; Multi-resolution singular value decomposition;
D O I
10.1016/j.optlastec.2022.108362
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
When laser-induced shock (LIS) wave characteristics testing is carried out using laser interference methods, the electrical noise, vibration noise, jitter or offset of the diffuse reflective surface during high-speed motion and other factors can lead to superposition or offset of the noise signal frequency with the low-frequency phase of the useful signal. As a result, problems such as phase shift of the useful signal and difficulty in extracting the initial position of the wavelet ridge may appear, and the initial position cannot be zeroed. By introducing a measurement factor through multi-resolution singular value decomposition and adaptively determining the optimal number of decomposition layers, zero-phase offset filtering is achieved and the signal-to-noise ratio (S/N) of the data is improved. According to the waveform decay characteristics of laser-induced shock wave velocity signals, the Shannon wavelet entropy method is proposed to accurately optimise the Morlet wavelet basis parameters to enhance the aggregation of wavelet scale spectrum time-frequency distribution. Simulation and test results show that: the proposed method overcomes the background noise interference and enables the initial velocity to be zeroed; the relative singular value points of the pulse are accurately symmetrically distributed and no phase shift occurs; the denoising performance is better than that of the wavelet method, the root mean square error is only 0.046, and the repeatability is strong; the error of the elastic wave velocity of the laser-induced shock wave at different power densities is within 3.2%; the relative velocity resolution remains constant at low/high frequencies, effectively avoiding false peaks and misclassification of the velocity profile.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Evaluating the Probability of Detecting Acoustic Emission Signals Using the Amplitude Discrimination Method with a Low Signal-to-Noise Ratio
    I. A. Rastegaev
    I. S. Yasnikov
    I. I. Rastegaeva
    E. A. Agletdinov
    D. L. Merson
    Russian Journal of Nondestructive Testing, 2022, 58 : 157 - 166
  • [22] Obtaining Time Derivative of Low-Frequency Signals With Improved Signal-to-Noise Ratio
    Kruttiventi, Jayanth
    Wu, Jie
    Frankel, Jay I.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2010, 59 (03) : 596 - 603
  • [23] A scanning filtering method for enhancing the signal-to-noise ratio of chirped laser pulse
    Zeng Bing
    Zeng Shu-Guang
    Zhang Bin
    Sun Nian-Chun
    Sui Zhan
    ACTA PHYSICA SINICA, 2012, 61 (15)
  • [24] Improving photoacoustic imaging in low signal-to-noise ratio by using spatial and polarity coherence
    Mao, Qiuqin
    Zhao, Weiwei
    Qian, Xiaoqin
    Tao, Chao
    Liu, Xiaojun
    PHOTOACOUSTICS, 2022, 28
  • [25] Denoising method for weak velocity test signals under laser-induced shock waves based on attention-guided multi-scale convolutional neural network
    Wu, Haonian
    Yan, Li
    Xv, Peiwen
    Tang, Yuyuan
    Xv, Ming
    Nie, Xiangfan
    OPTICS AND LASERS IN ENGINEERING, 2023, 170
  • [26] A Method of Quadrature Amplitude Modulation Signals Identification at Low Signal-to-noise Ratios
    Feng, Boyang
    Ji, Qingbo
    Lin, Yun
    PROCEEDINGS OF 2014 3RD ASIA-PACIFIC CONFERENCE ON ANTENNAS AND PROPAGATION (APCAP 2014), 2014, : 814 - 817
  • [27] Research on the Enhancement Method of Small Moving Targets with Low Signal-to-Noise Ratio
    Li, Kun
    Piao, Yupeng
    Qian, Weixian
    AOPC 2022: OPTICAL SENSING, IMAGING, AND DISPLAY TECHNOLOGY, 2022, 12557
  • [28] SIMPLE METHOD FOR IMPROVING TRANSDUCER SIGNAL-TO-NOISE RATIO IN AN MAGNETOSTRICTIVE WIRE READOUT SYSTEM
    MAKOWIECKI, D
    NUCLEAR INSTRUMENTS & METHODS, 1977, 144 (02): : 367 - 368
  • [29] A wavelet-based method for improving signal-to-noise ratio and contrast in MR images
    Alexander, ME
    Baumgartner, R
    Summers, AR
    Windischberger, C
    Klarhoefer, M
    Moser, E
    Somorjai, RL
    MAGNETIC RESONANCE IMAGING, 2000, 18 (02) : 169 - 180
  • [30] Research on the Enhancement Method of Small Moving Targets with Low Signal-to-Noise Ratio
    Li, Kun
    Piao, Yupeng
    Qian, Weixian
    INTERNATIONAL CONFERENCE ON OPTICAL AND PHOTONIC ENGINEERING, ICOPEN 2022, 2022, 12550