Performance of breathing filters under wet conditions: a laboratory evaluation

被引:18
|
作者
Turnbull, D [1 ]
Fisher, PC
Mills, GH
Morgan-Hughes, NJ
机构
[1] Univ Sheffield, Acad Anaesthet Unit, Sheffield, S Yorkshire, England
[2] Royal Hallamshire Hosp, Dept Anaesthet, Sheffield S10 2JF, S Yorkshire, England
[3] No Gen Hosp, Dept Anaesthet, Sheffield S5 7AU, S Yorkshire, England
关键词
equipment; breathing filters; safety; ventilation;
D O I
10.1093/bja/aei091
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Introduction. Heat and moisture exchangers in combination with a bacterial and viral filter (HMEF) are widely used during general anaesthesia. Excess patient secretions occluding the HMEF have been responsible for previous case reports of airway obstruction. A previous study suggested that differences in HMEF design might contribute to filter obstruction under wet conditions. Methods. We tested 14 types of HMEF under wet conditions to establish which design features contributed to HMEF obstruction. Incremental amounts of saline were added to each filter. The pressure across the filter was measured with an air flow of 60 litre min(-1). Results. We observed that saline added to the filter was often not easily visible to the casual observer. This concealment volume varied between filters. Ceramic hydrophobic pleated-membrane filters did not absorb saline and their resistance did not change. The composite filter where the moisture exchange component was either polyurethane foam or cellulose absorbed saline and contributed to a rise in resistance of 70-480% with the higher value more typical of the cellulose-paper-based HMEF. Conclusion. The ideal HMEF for use during general anaesthesia should prevent the passage of viral, bacterial and prion material, should provide this filtration performance even under wet conditions, should supplement humidification of the inspired air and anaesthetic gases and should not increase respiratory work. We have identified large variations in HMEF performance under wet conditions. Users should be aware of performance variation in HMEFs and use a filter suited to the intended application.
引用
收藏
页码:675 / 682
页数:8
相关论文
共 50 条
  • [1] PERFORMANCE OF GRASS FILTERS UNDER LABORATORY AND FIELD CONDITIONS
    HAYES, JC
    BARFIELD, BJ
    BARNHISEL, RI
    TRANSACTIONS OF THE ASAE, 1984, 27 (05): : 1321 - 1331
  • [2] Performance evaluation of wet chemical filters in semiconductor processing
    Jun, PK
    Park, HJ
    Lee, I
    Chae, SK
    Chon, SM
    Chung, HK
    INSTITUTE OF ENVIRONMENTAL SCIENCES 1996 PROCEEDINGS - CONTAMINATION CONTROL: SYMPOSIUM ON MINIENVIRONMENTS/42ND ANNUAL TECHNICAL MEETING - EXPANDING OUR TECHNICAL EXCELLENCE THROUGH EDUCATION, 1996, : 42 - 48
  • [3] Performance evaluation of pavement markings under dry, wet, and rainy conditions in the field
    Aktan, F
    Schnell, T
    MAINTENANCE MANAGEMENT AND SERVICES, 2004, (1877): : 38 - 49
  • [4] Evaluation of the changes in paper structure by the laboratory wet pressing conditions
    Sung, Yong Joo
    Keller, D. Steven
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2008, 14 (03) : 328 - 332
  • [5] Test method for cleanable filters under laboratory and operational conditions
    Gäng, P
    ADVANCES IN FILTRATION AND SEPARATION TECHNOLOGY, VOLS 13A AND 13B, 1999: ADVANCING FILTRATION AND SEPARATION SOLUTIONS FOR THE MILLENNIUM, 1999, : 104 - 112
  • [6] Performance Evaluation of Coir Geocells as Soil Retention System Under Dry and Wet Conditions
    Chitrachedu, Rajesh Kumar
    Kolathayar, Sreevalsa
    GEOTECHNICAL AND GEOLOGICAL ENGINEERING, 2020, 38 (06) : 6393 - 6406
  • [7] Performance Evaluation of Coir Geocells as Soil Retention System Under Dry and Wet Conditions
    Rajesh Kumar Chitrachedu
    Sreevalsa Kolathayar
    Geotechnical and Geological Engineering, 2020, 38 : 6393 - 6406
  • [8] An evaluation of the filtration performance of paediatric breathing system filters at low flows
    Malan, C. A.
    Wilkes, A. R.
    Hall, J. E.
    Gildersleve, C.
    ANAESTHESIA, 2007, 62 (05) : 504 - 508
  • [9] Laboratory investigation of capillary trapping under mixed-wet conditions
    Tanino, Y.
    Blunt, M. J.
    WATER RESOURCES RESEARCH, 2013, 49 (07) : 4311 - 4319
  • [10] Air flow resistance of wet breathing system filters - Reply
    Morgan-Hughes, NJ
    Mills, GH
    Northwood, D
    BRITISH JOURNAL OF ANAESTHESIA, 2002, 88 (03) : 451 - 452