An Evaluation of Useful Daylight Illuminance in an Office Room with a Light Shelf and Translucent Ceiling at 51° N

被引:12
|
作者
Brzezicki, Marcin [1 ]
机构
[1] Wroclaw Univ Sci & Technol, Fac Architecture, Prusa 53-55, PL-50317 Wroclaw, Poland
关键词
daylight simulation; light shelf; translucent ceiling; radiance; SHADING DEVICES; VISUAL COMFORT; PERFORMANCE; DESIGN; MODEL; IMPROVEMENT; VALIDATION; LUMINANCE; METRICS;
D O I
10.3390/buildings11110494
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The present study investigates the issue of computer-aided daylight evaluation in an office room with a light shelf and dropped translucent ceiling. In this type of room, daylight is admitted from two sources: (i) a standard window in the wall and (ii) via a light shelf and clerestory window, which illuminate the plenum located above the working space. The light from the plenum is transmitted through the translucent ceiling into the office room. The present study is based on data obtained through a computer-aided daylight simulation by DeLumin AE (DL-Light, ver. 11.0.9, and DL-Instant, ver. 6.1.4) software using the Radiance engine and real weather data for Wroclaw, Poland, at 51st lat. N. An office room of 12 x 6 m with different shading and daylight distribution scenarios was simulated (Variants 1-5). Next, the useful daylight illuminance (UDI (%)) for the range of 300-3000 lx and daylight glare probability (DGP) were calculated. To further optimize the daylighting scenarios, an adaptive shading system was simulated, which was activated when the illuminance value dropped below 300 lx. In the final variant, Variant 6, mean UDI300-3000 values were recorded to be above 80% for 95% of the area of the work plane. This allows the conclusion that a light shelf and translucent ceiling guide daylight deep into the room, improving uniformity and reducing glare when the standard window is covered by an adaptive shading system.
引用
收藏
页数:20
相关论文
共 10 条
  • [1] EVALUATION OF DAYLIGHT ILLUMINANCE ON THE PERFORMANCE OF LIGHT SHELVES OF AN OFFICE ROOM
    Mohapatra, Badri Narayan
    Kumar, M. Ravi
    Mandal, S. K.
    JOURNAL OF ENGINEERING SCIENCE AND TECHNOLOGY, 2019, 14 (04): : 1984 - 1999
  • [2] An Evaluation of Annual Luminous Exposure from Daylight in a Museum Room with a Translucent Ceiling
    Brzezicki, Marcin
    BUILDINGS, 2021, 11 (05)
  • [3] Analysis of the Impacts of Light Shelves on the Useful Daylight Illuminance in Office Buildings in Toronto
    Berardi, Umberto
    Anaraki, Hamid Khademi
    6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015), 2015, 78 : 1793 - 1798
  • [4] The benefits of light shelves over the daylight illuminance in office buildings in Toronto
    Berardi, Umberto
    Anaraki, Hamid Khademi
    INDOOR AND BUILT ENVIRONMENT, 2018, 27 (02) : 244 - 262
  • [5] Optimization of Useful Daylight Illuminance for Vertical Shading Fins Covered by Photovoltaic Panels for a Case Study of an Office Room in the City of Wroclaw, Poland
    Brzezicki, Marcin
    Regucki, Pawel
    Kasperski, Jacek
    BUILDINGS, 2021, 11 (12)
  • [6] A methodology for simulation of daylight room illuminance distribution and light dimming for a room with a controlled shading device
    Athienitis, AK
    Tzempelikos, A
    SOLAR ENERGY, 2002, 72 (04) : 271 - 281
  • [7] Evaluation of daylight illuminance in traditional dwellings: Main room/living room of Kula traditional dwellings
    Battal, Cansu
    Kazanasmaz, Tugce
    Ipekoglu, Basak
    JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY, 2023, 38 (03): : 1519 - 1531
  • [8] Evaluation of External Light Shelf Performance in Relation to the Ceiling Types Used in Indoor Spaces
    Jung, Su-yeon
    Lee, Min-Goo
    Lee, Heangwoo
    ENERGIES, 2023, 16 (24)
  • [9] ILLUMINANCE AND LUMINANCE BASED RATIOS IN THE SCOPE OF PERFORMANCE TESTING OF A LIGHT SHELF-REFLECTIVE LOUVER SYSTEM IN A LIBRARY READING ROOM
    Oner, Merve
    Kazanasmaz, Tugce
    LIGHT & ENGINEERING, 2019, 27 (03): : 39 - 46
  • [10] SPATIAL BRIGHTNESS EVALUATION FOR OFFICE ROOM WITH UNEVEN DISTLIBUTION OF LIGHT; [光の偏在がある執務室における空間の明るさ評価]
    Yamaguchi H.
    Kato M.
    Yoshizawa N.
    Hara N.
    Miki Y.
    Journal of Environmental Engineering (Japan), 2022, 87 (800): : 648 - 656