Extension of the NIST spectral power-responsivity calibration service to 2500 nm

被引:7
|
作者
Eppeldauer, G. P. [1 ]
Yoon, H. W. [1 ]
Zeng, J. [1 ]
Larason, T. C. [1 ]
Houston, J. M. [1 ]
Khromchenko, V. [1 ]
机构
[1] Natl Inst Stand & Technol, Gaithersburg, MD 20899 USA
关键词
INGAAS PHOTODIODES;
D O I
10.1088/0026-1394/49/2/S112
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The National Institute of Standards and Technology (NIST) is working to extend the upper wavelength limit of the spectral power-responsivity calibration service from 1800 nm to 2500 nm. This extension is based on extended-InGaAs (EIGA) transfer-and working-standard radiometers and low-NEP pyroelectric transfer-standard detectors. The scale is traceable to the electrical-substitution cryogenic radiometer through the transfer-standard EIGA radiometers. The total uncertainty of the extended-responsivity reference scale (realized on four EIGA working-standard radiometers) is 1% (k = 2). The transfer of the reference scale from one of the four working standards to a test EIGA radiometer in direct-current (dc) measurement mode is described. The uncertainty of the transferred scale is 1.6% (k = 2) between 1200 nm and 2300 nm. The transfer was performed on the NIST Spectral Comparator Facility (SCF) without any modifications to the SCF. The EIGA radiometers have been characterized for spatial-response uniformity, temperature-dependent spectral responsivity, linearity, noise, long-term and short-term temporal stability. The preliminary results show that EIGA radiometers can be used over the spectral range between 900 nm and 2500 nm in dc mode and could eventually replace the regular InGaAs detectors in the SCF measurements. The total uncertainty budget for these measurements is discussed.
引用
收藏
页码:S112 / S117
页数:6
相关论文
共 15 条
  • [1] EXTENSION OF THE NIST SPECTRAL POWER AND IRRADIANCE RESPONSIVITY CALIBRATIONS TO 2.5 MICROMETERS
    Eppeldauer, G. P.
    Zeng, J.
    Yoon, H. W.
    Larason, T. C.
    PROCEEDINGS OF THE CIE EXPERT SYMPOSIUM ON SPECTRAL AND IMAGING METHODS FOR PHOTOMETRY AND RADIOMETRY, 2010, : 66 - 71
  • [2] A bilateral comparison of spectral responsivity measurements in the spectral range 250 nm to 1800 nm between the NIST (USA) and the NRC (Canada)
    Boivin, LP
    Bruce, SS
    METROLOGIA, 2003, 40 (01) : S45 - S49
  • [3] Calibration of the spectral radiant power responsivity of windowed pyroelectric radiometers from 785 nm to 14 μm
    Zeng, Jinan
    Hanssen, Leonard
    INFRARED SPACEBORNE REMOTE SENSING AND INSTRUMENTATION XVI, 2008, 7082
  • [4] Extension of the NIST spectral responsivity scale to the infrared using improved-NEP pyroelectric detectors
    Eppeldauer, G. P.
    Zeng, J.
    Yoon, H. W.
    Wilthan, B.
    Larason, T. C.
    Hanssen, L. M.
    METROLOGIA, 2009, 46 (04) : S155 - S159
  • [5] Accurate calibration of the spectral responsivity of silicon trap detectors between 350 nm and 1064 nm
    Li Jian-Jun
    Zheng Xiao-Bing
    Lu Yun-Jun
    Zhang-Wei
    Xie Ping
    Zou Peng
    ACTA PHYSICA SINICA, 2009, 58 (09) : 6273 - 6278
  • [6] Extension of the NIST AC-DC difference calibration service for current to 100 kHz
    Kinard, JR
    Lipe, TE
    Childers, CB
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 1997, 102 (01) : 75 - 83
  • [7] Calibration of photo-detector's absolute spectral responsivity in the wavelength range 300 nm to 1000 nm
    Meng, Haifeng
    Xiong, Limin
    Xu, Nan
    He, Yingwei
    Zhang, Junchao
    Zhang, Bifeng
    2017 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY - OPTOELECTRONIC MEASUREMENT TECHNOLOGY AND SYSTEMS, 2017, 10621
  • [8] Electrical substitution cryogenic radiometer based spectral responsivity scale between 250-2500 nm wavelengths
    Bazkir, Ö
    Samedov, F
    OPTICA APPLICATA, 2004, 34 (03) : 427 - 438
  • [9] Spectral power and irradiance responsivity calibration of InSb working-standard radiometers
    Eppeldauer, G
    Rácz, M
    APPLIED OPTICS, 2000, 39 (31) : 5739 - 5744
  • [10] Spectral power and irradiance responsivity calibration of InSb working-standard radiometers
    Eppeldauer, George
    Rácz, Miklós
    Applied Optics, 2000, 39 (31): : 5739 - 5744