Adaptive Least Mean Square Controller for Power Quality Enhancement in Solar Photovoltaic System

被引:3
|
作者
Karchi, Nalini [1 ,2 ]
Kulkarni, Deepak [1 ]
Perez de Prado, Rocio [3 ]
Divakarachari, Parameshachari Bidare [4 ]
Patil, Sujata N. [5 ]
Desai, Veena [6 ]
机构
[1] Gogte Inst Technol, Dept Elect & Elect Engn, Belagavi 590006, India
[2] KLE Dr MS Sheshgiri Coll Engn & Technol, Dept Elect & Elect Engn, Belagavi 590008, India
[3] Univ Jaen, Telecommun Engn Dept, Jaen 23700, Spain
[4] Nitte Meenakshi Inst Technol, Dept Elect & Commun Engn, Bangalore 560064, India
[5] KLE Dr MS Sheshgiri Coll Engn & Technol, Dept Elect & Commun Engn, Belagavi 590008, India
[6] Gogte Inst Technol, Dept Elect & Commun Engn, Belagavi 590006, India
关键词
adaptive control algorithm; inverter controller; least mean square; maximum power point tracking; photovoltaic system; power quality issues; ALGORITHM;
D O I
10.3390/en15238909
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The objective of the proposed work is to develop a Maximum Power Point Tracking (MPPT) controller and inverter controller by applying the adaptive least mean square (LMS) algorithm to control the total harmonics distortion of a solar photovoltaic system. The advantage of the adaptive LMS algorithm is given by its simplicity and reduced required computational time. The adaptive LMS algorithm is applied to modify the Perturb and Observe (P&O), MPPT controller. In this controller, the adaptive LMS algorithm is used to predict solar photovoltaic power. The adaptive LMS maximum power point tracking controller gives better optimal solutions with less steady error 0.7% (6 watts) and 0% peak overshot in power with the tradeoff being more settling time at 0.33 s. The development of the inverter control law is performed using the d-q frame theory. This helps to reduce the number of equations to build a control law. The load current, grid current and grid voltage are sensed and transformed into d and q components. This adaptive LMS control law is used to extract the reference grid currents and, later, to compare them with the actual grid currents. The result of this comparison is used to generate the switching gate pulses for the inverter switches. The proposed controllers are developed and implemented with a solar PV system in MATLAB Simulink. The total harmonics distortion in grid and load current (3.25% and 7%) and voltage (0%) is investigated under linear and non-linear load conditions with changes in solar irradiations. The analysis is performed by selecting step incremental values and sampling time.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Adaptive least mean square behavioral power modeling
    Bogliolo, A
    Benini, L
    DeMicheli, G
    EUROPEAN DESIGN & TEST CONFERENCE - ED&TC 97, PROCEEDINGS, 1997, : 404 - 410
  • [2] Improved multifunctional controller for power quality enhancement in grid integrated solar photovoltaic systems
    Chacko, Fossy Mary
    George, Ginu Ann
    Jayan, M. V.
    Prince, A.
    WORLD JOURNAL OF ENGINEERING, 2020, 17 (04) : 585 - 598
  • [3] Adjoint least mean square control for solar photovoltaic array grid-connected energy generating system
    Singh, Sunaina
    Kewat, Seema
    Singh, Bhim
    Panigrahi, Bijaya Ketan
    IET ENERGY SYSTEMS INTEGRATION, 2022, 4 (01) : 72 - 86
  • [4] Power quality enhancement of grid-integrated solar photovoltaic system with unified power quality conditioner
    Manohara, M.
    Muthukaruppasamy, S.
    Dharmaprakash, R.
    Sendilkumar, S.
    Bharadwaj, D. Dattatreya
    Parimalasundar, E.
    ELECTRICAL ENGINEERING & ELECTROMECHANICS, 2024, (06) : 44 - 48
  • [5] Fast Adaptive Least Mean Square Algorithm
    Maity, S.
    Dasgupta, S.
    Gupta, B.
    PROCEEDINGS OF PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM (PIERS 2012), 2012, : 1666 - 1669
  • [6] Comparative study Of the Least Mean Square and Normalized Least Mean Square adaptive filters for positioning purposes
    El Mourabit, Ilham
    Badri, Abdelmajid
    Sahel, Aicha
    Baghdad, Abdennaceur
    PROCEEDINGS OF 2014 MEDITERRANEAN MICROWAVE SYMPOSIUM (MMS2014), 2014, : 123 - 126
  • [7] A Modified Least Mean Square Algorithm for Adaptive Frequency Estimation in Power Systems
    Barbosa, Daniel
    Monaro, Renato Machado
    Coury, Denis Vinicius
    Oleskovicz, Mario
    2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 4299 - 4304
  • [8] Control of Grid Integrated Photovoltaic system using new Variable Step Size Least Mean Square adaptive filter
    Avdhesh kumar
    Rachana Garg
    Priya Mahajan
    Electrical Engineering, 2021, 103 : 2945 - 2959
  • [9] Control of Grid Integrated Photovoltaic system using new Variable Step Size Least Mean Square adaptive filter
    Kumar, Avdhesh
    Garg, Rachana
    Mahajan, Priya
    ELECTRICAL ENGINEERING, 2021, 103 (06) : 2945 - 2959
  • [10] Comparative Performance of Wiener Filter and Adaptive Least Mean Square-Based Control for Power Quality Improvement
    Badoni, Manoj
    Singh, Alka
    Singh, Bhim