Lead isotope homogeneity of NIST SRM 610 and 612 glass reference materials: Constraints from laser ablation multicollector ICP-MS (LA-MC-ICP-MS) analysis

被引:33
|
作者
Kent, Adam J. R. [1 ]
机构
[1] Oregon State Univ, Dept Geosci, Corvallis, OR 97331 USA
关键词
laser ablation; Pb isotopes; reference materials; NIST SRM 610; NIST SRM 612; homogeneity;
D O I
10.1111/j.1751-908X.2008.00872.x
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
This contribution presents data for laser ablation multicollector ICP-MS (LA-MC-ICP-MS) analyses of NIST SRM 610 and 612 glasses with the express purpose of examining the Pb isotope homogeneity of these glasses at the similar to 100 mu m spatial scale, relevant to in situ analysis. Investigation of homogeneity at these scales is important as these glasses are widely used as calibrators for in situ measurements of Pb isotope composition. Results showed that at the levels of analytical uncertainty obtained, there was no discernable heterogeneity in Pb isotope composition of NIST SRM 610 and also most probably for NIST SRM 612. Traverses across the similar to 1.5 mm glass wafers supplied by NIST, consisting of between 75 and 133 individual measurements, showed no compositional outliers at the two standard deviation level beyond those expected from population statistics. Overall, the measured Pb isotope ratios from individual traverses across NIST SRM 610 and 612 wafers closely approximate single normally-distributed populations, with standard deviations similar to the average internal uncertainty for individual measurement blocks. Further, Pb isotope ratios do not correlate with Tl/Pb ratios measured during the analysis, suggesting that regions of volatile element depletion (marked by low Tl/Pb) in these glasses are not associated with changes in Pb isotope composition. For NIST SRM 610 there also appeared to be no variation in Pb isotope composition related to incomplete mixing of glass base and trace element spike during manufacture. For NIST SRM 612 there was some dispersion of measured ratios, including some in a direction parallel to the expected mixing line for base-spike mixing. However, there was no significant correlation parallel to the mixing line. At this time this cannot be unequivocally demonstrated to result from glass heterogeneity, but it is suggested that NIST SRM 610 be preferred for standardising in situ Pb isotope measurements. Data from this study also showed significantly better accuracy and somewhat better precision for ratios corrected for mass bias by external normalisation to Pb isotope ratios measured in bracketing calibrators compared to mass bias corrected via internal normalisation to measured (205)Tl/(203)Tl, although the Tl isotopic composition of both glasses appears to be homogeneous.
引用
收藏
页码:129 / 147
页数:19
相关论文
共 50 条
  • [1] Lead isotope analysis of Meroitic period glass from Nubia with LA-MC-ICP-MS
    Spedding, Juliet, V
    ARCHAEOMETRY, 2022, 64 (05) : 1148 - 1167
  • [2] Lead isotope analysis of melt inclusions by LA-MC-ICP-MS
    Zhang, Le
    Ren, Zhong-Yuan
    Nichols, Alexander R. L.
    Zhang, Yin-Hui
    Zhang, Yan
    Qian, Sheng-Ping
    Liu, Jian-Qiang
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (08) : 1393 - 1405
  • [3] In situ lithium isotope analysis by LA-MC-ICP-MS
    le Roux, P. J.
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2009, 73 (13) : A744 - A744
  • [4] Evaluation of the Homogeneity of the Uranium Isotope Composition of NIST SRM 610/611 by MC-ICP-MS, MC-TIMS, and SIMS
    Zimmer, Mindy M.
    Kinman, William S.
    Kara, Azim H.
    Steiner, Robert E.
    MINERALS, 2014, 4 (02): : 541 - 552
  • [5] Determination of Selenium Concentrations in NIST SRM 610, 612, 614 and Geological Glass Reference Materials Using the Electron Probe, LA-ICP-MS and SHRIMP II
    Jenner, Frances E.
    Holden, Peter
    Mavrogenes, John A.
    O'Neill, Hugh St. C.
    Allen, Charlotte
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2009, 33 (03) : 309 - 317
  • [6] Development of Synthetic Clinopyroxene Reference Materials for In Situ Lithium Isotope Measurement by LA-MC-ICP-MS
    Yang, Ao
    Lin, Jie
    Liu, Yongsheng
    Liu, Zhenyi
    Lin, Ran
    Deng, Kexin
    Hu, Zhaochu
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2023, 47 (03) : 535 - 546
  • [7] A potential stibnite reference material for sulfur isotope determination by LA-MC-ICP-MS
    Dai, Zhi-hui
    Fu, Shan-ling
    Liu, Yue-fu
    Meng, Yu-miao
    Bao, Zhi-an
    Hou, Ke-jun
    Lan, Ting-guang
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (01) : 216 - 226
  • [8] Solution and laser ablation MC-ICP-MS lead isotope analysis of gold
    Standish, Christopher
    Dhuime, Bruno
    Chapman, Robert
    Coath, Christopher
    Hawkesworth, Chris
    Pike, Alistair
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (02) : 217 - 225
  • [9] ANALYSIS OF TITANIUM ISOTOPE RATIOS IN REFRACTORY INCLUSIONS BY LA-MC-ICP-MS
    Williams, C. D.
    Wadhwa, M.
    Janney, P. E.
    Hines, R. R.
    Bullock, E. S.
    MacPherson, G. J.
    METEORITICS & PLANETARY SCIENCE, 2011, 46 : A250 - A250
  • [10] Strontium, neodymium and lead isotope analyses of NIST glass certified reference materials: SRM 610, 612, 614
    Woodhead, JD
    Hergt, JM
    GEOSTANDARDS NEWSLETTER-THE JOURNAL OF GEOSTANDARDS AND GEOANALYSIS, 2001, 25 (2-3): : 261 - 266