On the accuracy of the measurement of propagation loss in channel waveguides using the Fabry-Perot resonance method

被引:2
|
作者
Sidorin, Y [1 ]
机构
[1] Agilent Technol Inc, Agilent Res Labs, Palo Alto, CA 94304 USA
关键词
waveguide loss; channel waveguides; lithium niobate; waveguide resonators; integrated optics; Fabry-Perot;
D O I
10.1016/S0030-4018(01)01306-2
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The resonance method of measuring the propagation losses in dielectric channel waveguides is revisited. We experimentally and theoretically demonstrate how the inadequate quality of the waveguide resonator preparation detrimentally affects the results of the measurements. Minute tilts (on the order of 1 degrees) of the anneal-proton-exchanged LiNbO3 waveguide facets result in overestimation of loss factor by several hundreds of percent. Conclusions based on this error may result in rejection of low-loss samples perfectly suitable for resonant waveguide devices and thus constitute a useful warning for the experimentalist involved in measurements of waveguide losses. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:325 / 330
页数:6
相关论文
共 50 条
  • [1] LOSS MEASUREMENT OF OPTICAL WAVEGUIDES BY USING FABRY-PEROT RESONATOR.
    Schlaak, H.F.
    Sulz, G.
    Zhan, Yuanling
    Guangxue Xuebao/Acta Optica Sinica, 1986, 6 (11): : 1005 - 1011
  • [2] Modified Fabry-Perot interferometric method for waveguide loss measurement
    Taebi, Sareh
    Khorasaninejad, Mohammadreza
    Saini, Simarjeet Singh
    APPLIED OPTICS, 2008, 47 (35) : 6625 - 6630
  • [3] ACCURACY OF FABRY-PEROT METHOD OF SEMICONDUCTOR-LASER GAIN MEASUREMENT
    ELMASHADE, MB
    ARNAUD, J
    ELECTRONICS LETTERS, 1987, 23 (11) : 568 - 570
  • [4] Multiple Resonators Coupling Effect in Waveguide Loss Measurement Using the Fabry-Perot Method
    Shen, Heliang
    Huang, Fei
    She, Xuan
    Chen, Kan
    Chen, Meng
    Fan, Wen
    Bi, Ran
    Wang, Lei
    Shu, Xiaowu
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2025, 67 (01)
  • [5] A new method of restraining the Fabry-Perot resonance
    Yin, JZ
    Du, GT
    Liu, SP
    Zhang, YT
    Yin, ZY
    Yang, HJ
    Yang, XI
    Ma, Y
    Li, WC
    Yang, SR
    OPTICAL AND QUANTUM ELECTRONICS, 2003, 35 (09) : 873 - 878
  • [6] Modeling of insertion loss of fiber Fabry-Perot filter with a bidirectional beam propagation method
    Qi, Haibing
    Yu, Yonglin
    PASSIVE COMPONENTS AND FIBER-BASED DEVICES VII, 2011, 7986
  • [7] Characterization of photonic crystal waveguides using Fabry-Perot resonances
    Saeynaetjoki, A.
    Mulot, M.
    Arpiainen, S.
    Ahopelto, J.
    Lipsanen, H.
    JOURNAL OF OPTICS A-PURE AND APPLIED OPTICS, 2006, 8 (07): : S502 - S506
  • [8] Method of electron density measurement by Fabry-Perot interferometry
    Hojo, H
    Mase, A
    IRMMW-THz2005: The Joint 30th International Conference on Infrared and Millimeter Waves and 13th International Conference on Terahertz Electronics, Vols 1 and 2, 2005, : 26 - 27
  • [9] Loss Measurement of High-Finesse Fabry-Perot Cavities
    李刘锋
    李艳
    陈李生
    中国激光, 2010, 37 (12) : 3075 - 3080
  • [10] MEASUREMENT OF RUBY LASER CAVITY LOSSES BY FABRY-PEROT RESONANCE
    NELSON, DF