On the use of fluorescent probes to estimate free Mg2+ in the matrix of heart mitochondria

被引:19
|
作者
Jung, DW [1 ]
Chapman, CJ [1 ]
Baysal, K [1 ]
Pfeiffer, DR [1 ]
Brierley, GP [1 ]
机构
[1] OHIO STATE UNIV, DEPT MED BIOCHEM, COLUMBUS, OH 43210 USA
关键词
mitochondrial [Mg2+; fluorescent probes; furaptra; mag-indo-1; mag-fura-5; ionophores;
D O I
10.1006/abbi.1996.0311
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The fluorescent probe furaptra shows increases and decreases in the concentration of free magnesium ion, [Mg2+], in the mitochondrial matrix with changes in total Mg2+ and ligand availability. The factors involved in the calibration of these fluorescence changes in terms of absolute [Mg2+] have been investigated, The affinity of furaptra for Mg2+ is highly dependent on both temperature and ionic strength. The K-d for Mg-furaptra in solution in 100 mM KCl was found to be 2.1 +/- 0.1 mM at 25 degrees C. The use of this K-d to calculate matrix [Mg2+] is more reliable than in situ K-d measurements because ionophores, such as BrA23187 and ionomycin, do not equilibrate external Mg2+ with the matrix in an acceptable way. Furaptra is present at high concentrations (up to 500 mu M) in the matrix when introduced by hydrolysis of the acetoxymethyl ester. However, absorbance spectra of aqueous solutions show no evidence of dimerization of the probe or other changes in properties at these concentrations, Fluorescence intensity at 340 nm(ex) is strongly attenuated for matrix-sequestered furaptra, mag-fura-5, and mag-indo-1. This appears to result in part from preferential binding of the Mg-probe to mitochondrial proteins, The fluorescence of uncomplexed furaptra at 375-380 nm(ex) seems unaffected by protein binding, however, and changes in intensity in this region of the spectrum can be used in conjunction with the K-d found in aqueous solution to estimate matrix [Mg2+]. The presence of secondary equilibria, such as protein binding, and possible changes in ionic strength may undermine exact quantitation by this method, However, values for matrix [Mg2+] obtained in this way (0.5 to 0.7 mM) correspond well to estimates by other available methods and each of these methods suffers from comparable uncertainties. (C) 1996 Academic Press, Inc.
引用
收藏
页码:19 / 29
页数:11
相关论文
共 50 条
  • [1] On the relationship between matrix free Mg2+ concentration and total Mg2+ in heart mitochondria
    Jung, DW
    Panzeter, E
    Baysal, K
    Brierley, GP
    [J]. BIOCHIMICA ET BIOPHYSICA ACTA-BIOENERGETICS, 1997, 1320 (03): : 310 - 320
  • [2] MEASUREMENT OF MATRIX FREE MG-2+ CONCENTRATION IN RAT-HEART MITOCHONDRIA BY USING ENTRAPPED FLUORESCENT-PROBES
    RUTTER, GA
    OSBALDESTON, NJ
    MCCORMACK, JG
    DENTON, RM
    [J]. BIOCHEMICAL JOURNAL, 1990, 271 (03) : 627 - 634
  • [3] MEASUREMENT OF MATRIX MG-2+ CONCENTRATION OF RAT-HEART MITOCHONDRIA USING FLUORESCENT-PROBES
    RUTTER, GA
    OSBALDESTON, NJ
    MCCORMACK, JG
    DENTON, RM
    [J]. BIOCHEMICAL SOCIETY TRANSACTIONS, 1990, 18 (05) : 894 - 895
  • [4] MATRIX FREE MG-2+ OF HEART-MITOCHONDRIA
    JUNG, DW
    BRIERLEY, GP
    [J]. BIOPHYSICAL JOURNAL, 1990, 57 (02) : A562 - A562
  • [5] Naturally occurring thymol based fluorescent probes for detection of intracellular free Mg2+ ionf
    Adhikari, Susanta
    Ghosh, Avijit
    Guria, Subhajit
    Sarkar, Souvik
    Sahana, Animesh
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2016, 236 : 512 - 519
  • [6] Mg2+ and nitric oxide in rat heart mitochondria
    Manzo-Avalos, S
    Saavedra-Molina, A
    [J]. FASEB JOURNAL, 1998, 12 (08): : A1480 - A1480
  • [7] Modulation of oxidative phosphorylation by Mg2+ in rat heart mitochondria
    Rodriguez-Zavala, JS
    Moreno-Sánchez, R
    [J]. JOURNAL OF BIOLOGICAL CHEMISTRY, 1998, 273 (14) : 7850 - 7855
  • [8] MG2+ AND PERMEABILITY OF HEART-MITOCHONDRIA TO MONOVALENT CATIONS
    WEHRLE, JP
    JURKOWITZ, M
    SCOTT, KM
    BRIERLEY, GP
    [J]. ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 1976, 174 (01) : 312 - 323
  • [9] Matrix free Mg2+ and the regulation of mitochondrial volume
    Jung, DW
    Brierley, GP
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-CELL PHYSIOLOGY, 1999, 277 (06): : C1194 - C1201
  • [10] Fluorescent probes for the detection of magnesium ions (Mg2+): from design to application
    Liu, Min
    Yu, Xia
    Li, Ming
    Liao, Naixuan
    Bi, Anyao
    Jiang, Yueping
    Liu, Shao
    Gong, Zhicheng
    Zeng, Wenbin
    [J]. RSC ADVANCES, 2018, 8 (23): : 12573 - 12587