Utility of 3D CT Rib Study in Presurgical Planning of Autologous Ear Graft for Pinna Reconstruction in Microtia

被引:5
|
作者
Zanje, Sneha S. [1 ]
Kamat, Nikhil, V [1 ]
Taware, Kunal K. [1 ]
Rokade, M. L. [1 ]
Bhumkar, Ashesh C. [2 ]
机构
[1] Jupiter Scan Ctr, Dept Radiodiag, Mumbai 400602, Maharashtra, India
[2] Bhumkar ENT Hosp, Mumbai, Maharashtra, India
来源
关键词
3D CT VRT; autologous rib graft; microtia; COSTAL CARTILAGE FRAMEWORK; AURICULAR RECONSTRUCTION; AURICLE; EPIDEMIOLOGY; EXPERIENCE; REPAIR;
D O I
10.1055/s-0041-1735866
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The aim of this study was to demonstrate the utility of three-dimensional computed tomography (3D) CT rib study in presurgical planning to select the autologous rib cartilage graft for pinna reconstruction. Materials and Methods Total of 35 patients of microtia for autologous rib graft from April 2017 to February 2020 were evaluated in this study. All patients had a plain low-dose multislice CT chest. The length of costal cartilages of sixth to ninth ribs bilaterally and width and height of sixth and seventh rib costal cartilage synchondrosis were measured in 3D reconstructed true size coronal images with best possible length displayed. All patients had high-resolution computed tomography (HRCT) temporal studies done to evaluate for associated anomalies in external canal, middle ear cavities, and inner ear structures. Eleven patients had simultaneous HRCT temporal bone done after plain CT chest and rest who had done recent prior study were reviewed without repetition of study. Results There were 19 males and 16 females for 3D CT rib study. Average age of the participants was 16.5 years. The average width of synchondrosis of sixth and seventh rib was 15.4mm on right side and 14.7mm on left side, average height of synchondrosis was 28.5mm on right side and 30.7mm on left side. Average length of the eighth rib costal cartilage was 88.6mm on the right side and 90.5mm on the left side. Average length of the ninth rib was 63.2mm on the right side and 58.2mm on the left side. Costal cartilage calcifications were present in 9 patients. Conclusion Preoperative 3D CT rib study provides accurate measurements of rib stock for sculpting autologous ear graft.
引用
收藏
页码:586 / 595
页数:10
相关论文
共 50 条
  • [1] Microtia Ear Reconstruction with Patient-Specific 3D Models-A Segmentation Protocol
    Rodriguez-Arias, Juan Pablo
    Gutierrez Venturini, Alessandro
    Pampin Martinez, Marta Maria
    Gomez Garcia, Elena
    Munoz Caro, Jesus Manuel
    San Basilio, Maria
    Martin Perez, Mercedes
    Cebrian Carretero, Jose Luis
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (13)
  • [2] Utility of 3D Reconstruction for Surgical Planning in the Treatment of Retroperitoneal Sarcomas
    Fuertes, M. Jimenez
    Figueroa, A. Vizarreta
    Carrillo, J.
    Martin, M.
    Triana, D. Romero
    Prieto, V. Dominguez
    Qian, S.
    Campos, P. Villarejo
    BJS-BRITISH JOURNAL OF SURGERY, 2025, 112 : 2 - 2
  • [3] 3D CT Reconstruction from biplanar projections with integration of planning CT
    Cafaro, Alexandre
    Leroy, Amaury
    Beldjoudy, Guillaume
    Maury, Pauline
    Munoz, Alexandre
    Robert, Charlotte
    Lepetit, Vincent
    Paragios, Nikos
    Gregoire, Vincent
    Deutsch, Eric
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3807 - S3810
  • [4] Autologous ear reconstruction: Towards a semiautomatic cadbased procedure for 3D printable surgical guides
    Facchini F.
    Morabito A.
    Buonamici F.
    Mussi E.
    Servi M.
    Volpe Y.
    Volpe, Yary (yary.volpe@unifi.it), 2020, CAD Solutions, LLC (18): : 357 - 367
  • [5] The Utility of Smartphone 3D Scanning, Open-Sourced Computer-aided Design, and Desktop 3D Printing in the Surgical Planning of Microtia Reconstruction: a Step by Step Guide and Concept Assessment
    Alazzam, Abdualziz
    Aljarba, Sultan
    Alshomer, Feras
    Alawirdhi, Bassam
    JPRAS OPEN, 2021, 30 : 17 - 22
  • [6] 3D reconstruction from pilot views for CT based brachytherapy planning
    Aristophanous, M
    Pelizzari, C
    MEDICAL PHYSICS, 2004, 31 (06) : 1809 - 1809
  • [7] Study on 3D CT image reconstruction and interactive clipping
    Hu, Zhanli
    Li, Jin
    2008 INTERNATIONAL SPECIAL TOPIC CONFERENCE ON INFORMATION TECHNOLOGY AND APPLICATIONS IN BIOMEDICINE, VOLS 1 AND 2, 2008, : 560 - +
  • [8] Multiscale sterilizable 3D printed auricular templates to guide cartilaginous framework sizing and sculpture during autologous microtia reconstruction
    Alhazmi, Bushra
    Alshomer, Feras
    Alawirdhi, Bassam
    JPRAS OPEN, 2021, 28 : 121 - 125
  • [9] 3D printing of personalized polylactic acid scaffold laden with GelMA/autologous auricle cartilage to promote ear reconstruction
    Gui, Xingyu
    Peng, Zhiyu
    Song, Ping
    Chen, Li
    Xu, Xiujuan
    Li, Hairui
    Tang, Pei
    Wang, Yixi
    Su, Zixuan
    Kong, Qingquan
    Zhang, Zhenyu
    Li, Zhengyong
    Cen, Ying
    Zhou, Changchun
    Fan, Yujiang
    Zhang, Xingdong
    BIO-DESIGN AND MANUFACTURING, 2023, 6 (04) : 451 - 463
  • [10] 3D printing of personalized polylactic acid scaffold laden with GelMA/autologous auricle cartilage to promote ear reconstruction
    Xingyu Gui
    Zhiyu Peng
    Ping Song
    Li Chen
    Xiujuan Xu
    Hairui Li
    Pei Tang
    Yixi Wang
    Zixuan Su
    Qingquan Kong
    Zhenyu Zhang
    Zhengyong Li
    Ying Cen
    Changchun Zhou
    Yujiang Fan
    Xingdong Zhang
    Bio-Design and Manufacturing, 2023, 6 (04) : 451 - 463